Pressure Testing Heater Gas Connections:

1.Make sure that the heater supply piping sys- tem is connected and has been leak tested as described above.

2.Make sure control knob of heater is in OFF position.

3.Open equipment shutoff valve (see figure 13).

4.Open main gas valve on or near gas meter.

5.Check all joints from equipment shutoff valve to control valve (see figure 14). Apply mixture of liquid soap and water to gas joints. Bubbles forming show a leak.

6.Correct all leaks at once.

7.Light heater (see Operating Your Heater, pages 11 and 12 for thermostat models or pages 9 and 10 for non-thermostat models). Check the rest of the internal joints for leaks.

8.Turn off heater (see To Turn OFF Gas to Appli- ance, page 12 for thermostat models and page 11 for non-thermostat models).

9.Replace lower front panel.

Open

Equipment

Closed

Shutoff Valve

 

Figure 13

Control Valve

Gas Meter

Equipment

Shutoff Valve

Figure 14

ELECTRICAL WIRING DIAGRAM:

Figure 15

If any original wiring as supplied with the heater must be replaced, it must be replaced with type AWG 105oC wire or its equivalent except as indicated.

WARNING: Electrical Grounding Instructions: This heater is equipped with a three-prong (grounding) plug for your protection against shock hazard and should be plugged into a properly grounded three- prong receptacle.­

OPERATING YOUR HEATER

NON-THERMOSTAT MODELS IR10NG / BF6NG / BF10NG

FOR YOUR SAFETY READ BEFORE LIGHTING

WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing prop- erty damage, personal injury or loss of life.­

A.This appliance has a pilot that must be lighted by hand. When lighting the pilot, follow these instructions exactly.

B.BEFORE LIGHTING smell all around the appli- ance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS

Do not try to light any appliance.

Do not touch any electrical switch; do not use any phone in your building.

Immediately call you gas supplier from a neigh- bor’s phone. Follow the gas supplier’s instruc- tions.

If you can not reach your gas supplier, call the fire department.

Unvented Natural Gas Fired Room Heater

9

Installation Instructions and Owner’s Manual

Image 9
Contents MHBF30NGT MHBF20NGT MHBF6NG HSBF30NGT HSBF20NGT Blue Flame Heaters­ Plaque Heaters­TSBF30NGT TSBF20NGT HSBF10NG TSBF10NG MHIR30NGT MHIR20NGT HSIR30NGT HSIR20NGT HSIR10NG TSIR30NGT TSIR20NGT TSIR10NGPrecautions Carbon Monoxide PoisoningNatural Gas Thermostatic Control on Thermostat Models Safety DeviceLocal Codes Ignition SystemDetermining the Type of Heater Location Space Ventilation AIRVentilation from Inside Building This Installation Requires Installation Check GAS TypeVentilation from Outdoors Locating HeaterMounting Bracket Fastening Heater to WallInstalling Support Feet see figure Installing Bottom Mounting ScrewsConnecting to GAS Supply Placing Heater on Mounting BracketTest Pressure Equal To or Less Than ½ psig 3.5 kPa Test pressure in Excess of ½ psig 3.5kPaElectrical Wiring Diagram Pressure Testing Heater Gas ConnectionsFor Your Safety Read Before Lighting Operating Your HeaterFor IR only Lighting InstructionsOperating Your Heater Thermostat Models To Turn OFF GAS to ApplianceShutting OFF Heater Shutting OFF Burner only Pilot Stays LITInspecting Burner Thermostat Control OperationPilot Flame Pattern Burner Flame PatternCleaning ODS/PILOT and Burner Cleaning and MaintenanceCleaning Burner Pilot AIR Hole Inlet Cleaning Heater CabinetObserved SYMPTOM­ Possible CAUSE­ REMEDY­ TroubleshootingObserved SYMPTOM­ Possible CAUSE­ REMEDY­ Troubleshooting CON’TSpecifications IR10NG­ IR20NGT­ IR30NGT­BF6NG BF10NG­ BF20NGT BF30NGT­ BF20NGT BF30NGT Thermostat modelsIR20NGT IR30NGTFor all models, Equipment shutoff valve with 1/8 NPT tap ITEM­ Part NO.­IR20NGT­ BF20NGT­ IR30NGT­ BF30NGT­ Not sold separately Must purchase Assembly * Items not shown IR10NG, BF6NG and BF10NG Parts List ITEM­ Part NO.­ DESCRIPTION­IR10NG­ BF6NG BF10NG­ NON-Thermostat models IR10NGBF6NG3 BF10NG Parts Under Warranty REPLACEMENT­PARTSParts not Under Warranty Technical ServiceUnvented Natural Gas Fired Room Heater Model ­ Serial No. ­ Date Purchased ­ Warranty Information
Related manuals
Manual 24 pages 60.4 Kb

MHBF10NG, HSIR20NGT, HSBF10NG, MHIR10NG, MHIR20NGT specifications

The Enerco HSIR10NG, TSIR10NG, TSBF10NG, TSIR20NGT, and MHBF6NG are a line of innovative heating solutions designed to meet various heating needs in both residential and commercial applications. Each model is engineered with advanced technologies and features that prioritize efficiency, performance, and user convenience.

The HSIR10NG is a high-efficiency infrared heater that operates on natural gas. It provides powerful heating with minimal energy consumption, utilizing infrared technology to warm objects and people directly rather than just the surrounding air. This results in faster heating and lower energy costs, making it an ideal choice for garages, workshops, or outdoor spaces.

Following closely is the TSIR10NG, another natural gas infrared heater known for its compact design and efficiency. This model features a state-of-the-art burner design that maximizes heat output while ensuring low emissions. The TSIR10NG is particularly suited for smaller spaces, providing targeted heating where it is needed most. It can easily be mounted on walls or ceilings, offering versatility in installation options.

The TSBF10NG is a dual-fuel infrared heater, allowing users to switch between natural gas and propane as needed. This flexibility makes it suitable for various environments and user preferences. The heater's robust construction ensures durability, while its adjustable heating levels allow for customized comfort.

For larger areas, the TSIR20NGT offers an enhanced heating capacity with similar infrared technology. This model is ideal for industrial or commercial spaces requiring efficient heating. With its advanced thermostat controls, users can maintain a consistent temperature while benefiting from lower operational costs.

Lastly, the MHBF6NG is a portable heating solution designed for versatility and convenience. This compact model is perfect for temporary heating needs, featuring an easy-to-use design that allows for quick setup and relocation. Its propane compatibility makes it a popular choice for outdoor events, workshops, or emergency heating situations.

Each model is equipped with advanced safety features, including automatic shutoff mechanisms and durable heat-resistant materials, ensuring peace of mind during operation. The Enerco line is engineered not only for performance but also for ease of maintenance, making them reliable options for users seeking efficient heating solutions. Overall, Enerco's HSIR10NG, TSIR10NG, TSBF10NG, TSIR20NGT, and MHBF6NG provide a range of effective heating options tailored to diverse environments and user needs, combining innovation with practical functionality.