D. Vent Diagrams
WARNING
Fire Risk. Explosion Risk.
Do NOT pack insulation or other combustibles between ceiling firestops.
•ALWAYS maintain specified clearances around venting and firestop systems.
•Install wall shield and ceiling firestops as specified.
Failure to keep insulation or other material away from vent pipe may cause fire.
1.Top Vent - Horizontal Termination One Elbow
Figure 5.3
Two Elbows
V1 Minimum | H1 Maximum | |||||
3 ft. |
|
| 0.9 m | 2 ft. |
| 0.6 m |
4 ft. |
|
| 1.2 m | 4 ft. |
| 1.2 m |
5 ft. |
|
| 1.5 m | 6 ft. |
| 1.8 m |
12 ft. |
|
| 3.7m | 20 ft. |
| 6.1 m |
V1 | + H1 | = 40 ft. (12.2 m) Maximum | ||||
| H1 = 20 ft. (6.1 m) Maximum |
|
Note: When installing the TAOS surround and venting with one elbow, a straight sec- tion of venting (30 in. minimum) MUST be attached directly to starting collars on unit.
Note: The first elbow used MUST always be DVP90ST.
V1 Minimum | H1 + H2 Maximum | ||
3 ft. | 0.9 m | 2 ft. | 0.6 m |
4 ft. | 1.2 m | 4 ft. | 1.2 m |
5 ft. | 1.5 m | 6 ft. | 1.8 m |
12 ft. | 3.7 m | 20 ft. | 6.1 m |
V1 + H1 + H2 = 40 ft. (12.2 m) Maximum
H1 + H2 = 20 ft. (6.1 m) Maximum
Note: V1 MUST be a minimum of 3 feet unless using the TAOS surround. For TAOS surround, V1 minimum MUST be 30 in.
Note: The first elbow used
MUST always be DVP90ST.
Figure 5.4
Heat & Glo • Bravo • | 13 |