10 Electrical Information

A. Recommendation for Wire

This appliance requires 110-120 VAC be wired to the junc- tion box for proper operation of the appliance (Intellifire ignition).

Note: This appliance must be electrically wired and grounded in accordance with local codes or, in the absence of local codes, with National Electric Code ANSI/NFPA 70-latest edition or the Canadian Electric Code, CSA C221.1.

B. Connecting to the Appliance

WARNING

Wire 110V to electrical junction box.

Do NOT wire 110V to valve.

Do NOT wire 110V to wall switch.

Incorrect wiring will damage millivolt valves.

Incorrect wiring will override IPI safety lock- out and may cause explosion.

This appliance may be used with a wall switch, wall mounted thermostat and/or a remote control.

If using thermostat use one compatible with a millivolt gas valve system.

Follow parameters for locating thermostat (see individ- ual thermostat instructions) to ensure proper operation of appliance.

Use low resistance thermostat wire for wiring from igni- tion system to the wall switch and thermostat.

Keep wire lengths short as possible by removing any excess wire length.

Low voltage and 110 VAC voltage cannot be shared within the same wall box.

C. Intellifire Ignition System Wiring

This appliance requires a 110 VAC supply to the appliance junction box for operation. A wiring diagram is shown in Figure 10.1.

This appliance is equipped with an Intellifire control valve which operates on a 3 volt system.

This appliance is supplied with a battery pack and a 3 volt AC transformer, which requires the installation of the sup- plied junction box. It is highly recommended that the junc- tion box be installed at this time to avoid reconstruction.

The battery pack requires two D cell batteries (not in- cluded).

NOTE: Batteries cannot be placed in the battery pack while using the 3 volt AC transformer. The transformer must be unplugged if the battery pack is used or battery life will be reduced.

Wiring to the battery pack is left disconnected in order to conserve battery life. In the case of a loss of power, simply connect red and black wire leads to activate bat- tery power (connect red to red, black to black). The fire- place can be used as necessary. Once power (110 VAC) is restored, disconnect red and black wire leads to extend battery life.

CAUTION

Battery polarity must be correct or module damage will occur.

Optional Accessories Requirements

Wiring for optional accessories should be done now to avoid reconstruction.

D. Wall Switch (Required)

A wall switch must be installed of this fireplace. This will allow the unit to operate if the power goes out (battery operation).

Position the wall switch in the desired position on the wall. An assembly of 18 ft of 20 AWG is provided with the appliance to connect the wall switch to the appliance. Instead of the supplied assembly, wire with a length of 25 ft or less and a gauge of 20 AWG through 14 AWG is acceptable. The wire needs a jacket with a temperature rating of 140oF (60oC) or higher. At the appliance connect the wire to the ON/OFF switch pigtails.

Heat & Glo • Bravo • 704-902 Rev. E • 7/08

29

Image 29
Contents What to do if you smell gas Model BravoHomeowner Reference Information CongratulationsTable of Contents Listing and Code Approvals Requirements for the Commonwealth of Massachusetts Installation of Carbon Monoxide DetectorsTools and Supplies Needed Installation to ensure maximum safety and benefitGetting Started Selecting Appliance Location Framing and ClearancesClearance to Combustibles Constructing the Appliance ChaseClearances Clearances to Mantels or Combustibles above Appliance Mantel ProjectionsVent Termination Minimum Clearances Termination LocationsAlcove Applications Vent Table Key Vent Information and DiagramsUse of Elbows Measuring StandardsTop Vent Horizontal Termination One Elbow Vent DiagramsMinimum Maximum V1 Minimum H1 + H2 MaximumV1 + V2 Minimum H1 + H2 Maximum Top Vent Horizontal Termination Three ElbowsFlue Outlet Top Vent Vertical Termination No Elbow V1 = 46 ft. Max .0 mV1 Minimum H1 Maximum H1 + H2 Top Vent Vertical TerminationPipe Clearances to Combustibles Vent Clearances and FramingWall Penetration Framing Combustible Wall PenetrationVertical Penetration Framing Installing the Ceiling FirestopInstalling Attic Shield Securing and Leveling the Appliance Appliance PreparationAssembly of Vent Sections DVP Pipe Installing Vent PipeAttaching Vent to the Firebox Assembly Assembling Pipe SectionsAssembling DVP-12A Slip Sections Assembling Minimum Installations MI SectionsHorizontal Sections Disassembly of Vent SectionsSecuring the Vent Sections Vertical Sections Heat Shield Requirements for Horizontal Termination Installing Heat Shield and Horizontal Termination CapInstalling the Horizontal Termination Cap 13 Minimum Height from Roof to Lowest Installing Roof Flashing and Vertical Ter- mination Cap17 Assembling the Storm Collar Around the Pipe Assembling and Installing Storm CollarGas Pressures Gas InformationFuel Conversions Gas Connection High Altitude Installations Connecting to the Appliance Recommendation for WireIntellifire Ignition System Wiring Wall Switch RequiredLOW Voltage See Note GRN wire Ground attached To GRN screw with Inside box Junction Box InstallationFacing Material FinishingOption B Kiva-style Arch Finishing StylesOption a Flush Wall Finish Option C Southwestern kiva-style Option D Flush Wall Finish with Luxor Surround Flush wall installation with Luxor SurroundClean the Appliance Appliance SetupAccessories Lava Rock and Ember PlacementPositioning the Logs Log Assembly LOGS-BRAVORight Grate Tine LOG #6 Air Shutter Settings Glass AssemblyRemoving Glass Assembly Replacing Glass AssemblyBefore Lighting Appliance Operating InstructionsIntellifire Ignition Lighting ApplianceAfter Appliance is Lit Frequently Asked QuestionsInitial Break-in Procedure Sympton Possible Cause Corrective Action TroubleshootingIntellifire Ignition System Symptom Possible Cause Corrective Action Maintaining and Servicing Appliance Maintenance TasksRecommend addition of screen if one is not present Inspect Maintenance TasksReference Materials Appliance Dimension DiagramP 4 5 4 5 E lb o w Vent Components DiagramsDVP-TRAP1 DVP-TRAPK2 DVP-TRAP2 DVP-TRAPK1 DVP-HSM-B DVP and SL Series ComponentsDVP-HRC, DVP-HRC-SS Not Approved for ALL Units Service Parts List Log Set AssemblyAt Depot StockedIntermittent Pilot Ignition Limited Lifetime Warranty Heat & GLO GAS Appliance Products Limited Lifetime WarrantyDo not Discard this Manual Contact Information

704-902 specifications

The Heat & Glo LifeStyle 704-902 is a modern gas fireplace that exemplifies the marriage of cutting-edge technology and aesthetic design, making it a popular choice for homeowners looking to enhance their living spaces with warmth and style. This fireplace is particularly noted for its versatility and the ambiance it creates, turning any room into a cozy retreat.

One of the standout features of the LifeStyle 704-902 is its contemporary design, which often includes a clean and sleek look that can fit seamlessly into various home décor styles. It offers customizable trim options, allowing homeowners to personalize the fireplace to match their interiors perfectly. The large viewing area permits a panoramic view of the flame, creating an inviting focal point in the room.

Equipped with innovative technologies, the LifeStyle 704-902 ensures efficient heat distribution and energy consumption. The fireplace features a direct vent system, which uses outside air for combustion and expels exhaust gases outside, making it a safe and efficient option for heating. This system not only enhances safety but also provides improved indoor air quality.

The product is designed for user convenience, featuring easy-to-use controls, allowing homeowners to adjust the flame height and heat output effortlessly. The IntelliFire® ignition system is particularly noteworthy, as it provides reliable start-ups and can be operated with a remote control or mobile app, offering flexibility and ease of use.

In terms of efficiency, the Heat & Glo LifeStyle 704-902 excels with high Annual Fuel Utilization Efficiency (AFUE) ratings. This means that it converts a significant portion of the fuel it uses into usable heat, delivering optimal performance while keeping utility costs in check. Additionally, the fireplace can be equipped with optional fan kits that enhance air circulation, further increasing its heating capabilities.

Another characteristic of the LifeStyle 704-902 is its variety of decorative media options, such as logs, stones, and glass, which allow owners to customize the look of the firebox. This versatility ensures that the fireplace can adapt to individual tastes, making it a perfect addition to any home.

In summary, the Heat & Glo LifeStyle 704-902 combines modern aesthetics, innovative technologies, and customizable features to deliver an exceptional heating solution. Its efficiency, ease of use, and design flexibility make it a leading choice for those seeking comfort and style in their homes.