Heat & Glo LifeStyle 704-902 owner manual Getting Started, Tools and Supplies Needed

Page 6

2 Getting Started

A. Design and Installation Considerations

C. Inspect Appliance and Components

Heat & Glo direct vent gas appliances are designed to

WARNING

operate with all combustion air siphoned from outside of

the building and all exhaust gases expelled to the outside.

Inspect appliance and components for damage.

No additional outside air source is required.

 

Damaged parts may impair safe operation.

CAUTION

• Do NOT install damaged components.

• Do NOT install incomplete components.

 

 

• Do NOT install substitute components.

Check building codes prior to installation.

Report damaged parts to dealer.

Installation MUST comply with local, regional, state and national codes and regulations.

 

• Consult local building, fire officials or authorities having jurisdic-

Carefully remove the appliance and components from

 

tion about restrictions, installation inspection, and permits.

 

the packaging.

 

 

 

 

• The vent system components and trim doors are shipped

When planning an appliance installation, it’s necessary to

 

in separate packages.

determine the following information before installing:

The gas logs may be packaged separately and must be

Where the appliance is to be installed.

 

field installed.

The vent system configuration to be used.

Report to your dealer any parts damaged in shipment,

Gas supply piping.

 

 

particularly the condition of the glass.

 

Read all of the instructions before starting the insta-

Electrical wiring.

 

 

 

llation. Follow these instructions carefully during the

Framing and finishing details.

 

 

installation to ensure maximum safety and benefit.

Whether optional accessories—devices such as a wall

 

 

 

 

switch, or remote control—are desired.

 

 

WARNING

 

 

 

 

 

 

 

 

 

WARNING

 

 

Hearth & Home Technologies disclaims any

 

 

 

 

 

responsibility for, and the warranty will be voided

 

Keep appliance dry.

 

 

by, the following actions:

 

 

Installation and use of any damaged appliance or vent

 

Mold or rust may cause odors.

 

 

 

 

system component.

 

Water may damage controls.

 

 

 

 

Modification of the appliance or vent system.

 

 

 

 

 

 

 

 

 

 

Installation other than as instructed by Hearth & Home

B. Tools and Supplies Needed

 

 

Technologies.

Before beginning the installation be sure that the following

 

• Improper positioning of the gas logs or the glass door.

 

• Installation and/or use of any component part not approved

tools and building supplies are available.

 

 

 

by Hearth & Home Technologies.

 

 

 

 

 

 

Reciprocating saw

Framing material

 

Any such action may cause a fire hazard.

Pliers

 

Hi temp caulking material

 

 

 

Hammer

 

Gloves

 

 

 

Phillips screwdriver

Framing square

 

 

 

Flat blade screwdriver

Electric drill and bits (1/4 in.)

 

 

 

Plumb line

 

Safety glasses

 

 

 

Level

 

1/2 - 3/4 inch length, #6 or #8 Self-drilling screws

Manometer

 

Voltmeter

 

 

 

Tape measure

 

Noncorrosive leak check solution

 

 

 

6

Heat & Glo • Bravo • 704-902 Rev. E • 7/08

Image 6
Contents Model Bravo What to do if you smell gasCongratulations Homeowner Reference InformationTable of Contents Listing and Code Approvals Installation of Carbon Monoxide Detectors Requirements for the Commonwealth of MassachusettsInstallation to ensure maximum safety and benefit Getting StartedTools and Supplies Needed Framing and Clearances Selecting Appliance LocationConstructing the Appliance Chase ClearancesClearance to Combustibles Mantel Projections Clearances to Mantels or Combustibles above ApplianceTermination Locations Vent Termination Minimum ClearancesAlcove Applications Use of Elbows Vent Information and DiagramsVent Table Key Measuring StandardsMinimum Maximum Vent DiagramsTop Vent Horizontal Termination One Elbow V1 Minimum H1 + H2 MaximumTop Vent Horizontal Termination Three Elbows V1 + V2 Minimum H1 + H2 MaximumTop Vent Vertical Termination No Elbow V1 = 46 ft. Max .0 m Flue OutletV1 Minimum H1 Maximum Top Vent Vertical Termination H1 + H2Wall Penetration Framing Vent Clearances and FramingPipe Clearances to Combustibles Combustible Wall PenetrationInstalling the Ceiling Firestop Installing Attic ShieldVertical Penetration Framing Appliance Preparation Securing and Leveling the ApplianceAttaching Vent to the Firebox Assembly Installing Vent PipeAssembly of Vent Sections DVP Pipe Assembling Pipe SectionsAssembling Minimum Installations MI Sections Assembling DVP-12A Slip SectionsDisassembly of Vent Sections Securing the Vent Sections Vertical SectionsHorizontal Sections Installing Heat Shield and Horizontal Termination Cap Installing the Horizontal Termination CapHeat Shield Requirements for Horizontal Termination Installing Roof Flashing and Vertical Ter- mination Cap 13 Minimum Height from Roof to LowestAssembling and Installing Storm Collar 17 Assembling the Storm Collar Around the PipeGas Information Fuel Conversions Gas ConnectionGas Pressures High Altitude Installations Intellifire Ignition System Wiring Recommendation for WireConnecting to the Appliance Wall Switch RequiredLOW Voltage See Note Junction Box Installation GRN wire Ground attached To GRN screw with Inside boxFinishing Facing MaterialFinishing Styles Option a Flush Wall FinishOption B Kiva-style Arch Option C Southwestern kiva-style Flush wall installation with Luxor Surround Option D Flush Wall Finish with Luxor SurroundAccessories Appliance SetupClean the Appliance Lava Rock and Ember PlacementLog Assembly LOGS-BRAVO Positioning the LogsRight Grate Tine LOG #6 Removing Glass Assembly Glass AssemblyAir Shutter Settings Replacing Glass AssemblyOperating Instructions Before Lighting ApplianceLighting Appliance Intellifire IgnitionFrequently Asked Questions Initial Break-in ProcedureAfter Appliance is Lit Troubleshooting Intellifire Ignition SystemSympton Possible Cause Corrective Action Symptom Possible Cause Corrective Action Maintenance Tasks Maintaining and Servicing ApplianceInspect Maintenance Tasks Recommend addition of screen if one is not presentAppliance Dimension Diagram Reference MaterialsVent Components Diagrams P 4 5 4 5 E lb o wDVP-TRAP1 DVP-TRAPK2 DVP-TRAP2 DVP-TRAPK1 DVP and SL Series Components DVP-HSM-BDVP-HRC, DVP-HRC-SS Not Approved for ALL Units Log Set Assembly Service Parts ListStocked At DepotIntermittent Pilot Ignition Limited Lifetime Warranty Limited Lifetime Warranty Heat & GLO GAS Appliance ProductsContact Information Do not Discard this Manual

704-902 specifications

The Heat & Glo LifeStyle 704-902 is a modern gas fireplace that exemplifies the marriage of cutting-edge technology and aesthetic design, making it a popular choice for homeowners looking to enhance their living spaces with warmth and style. This fireplace is particularly noted for its versatility and the ambiance it creates, turning any room into a cozy retreat.

One of the standout features of the LifeStyle 704-902 is its contemporary design, which often includes a clean and sleek look that can fit seamlessly into various home décor styles. It offers customizable trim options, allowing homeowners to personalize the fireplace to match their interiors perfectly. The large viewing area permits a panoramic view of the flame, creating an inviting focal point in the room.

Equipped with innovative technologies, the LifeStyle 704-902 ensures efficient heat distribution and energy consumption. The fireplace features a direct vent system, which uses outside air for combustion and expels exhaust gases outside, making it a safe and efficient option for heating. This system not only enhances safety but also provides improved indoor air quality.

The product is designed for user convenience, featuring easy-to-use controls, allowing homeowners to adjust the flame height and heat output effortlessly. The IntelliFire® ignition system is particularly noteworthy, as it provides reliable start-ups and can be operated with a remote control or mobile app, offering flexibility and ease of use.

In terms of efficiency, the Heat & Glo LifeStyle 704-902 excels with high Annual Fuel Utilization Efficiency (AFUE) ratings. This means that it converts a significant portion of the fuel it uses into usable heat, delivering optimal performance while keeping utility costs in check. Additionally, the fireplace can be equipped with optional fan kits that enhance air circulation, further increasing its heating capabilities.

Another characteristic of the LifeStyle 704-902 is its variety of decorative media options, such as logs, stones, and glass, which allow owners to customize the look of the firebox. This versatility ensures that the fireplace can adapt to individual tastes, making it a perfect addition to any home.

In summary, the Heat & Glo LifeStyle 704-902 combines modern aesthetics, innovative technologies, and customizable features to deliver an exceptional heating solution. Its efficiency, ease of use, and design flexibility make it a leading choice for those seeking comfort and style in their homes.