Heat & Glo LifeStyle 704-902 owner manual Reference Materials, Appliance Dimension Diagram

Page 48

16 Reference Materials

A. Appliance Dimension Diagram

Dimensions are actual appliance dimensions. Use for reference only. For framing dimensions and clearances refer to Section 3.

M

N

GAS LINE

ACCESS

O

P

K

L

Ø J

I

A

ELECTRICAL

H

 

ACCESS

B CG

D

E

F

Location

Inches

Millimeters

A

34-3/8

875

B

43-1/2

1104

C

6-1/8

157

D

3

77

E*

9-3/8

237

F*

27-3/4

706

G

40

1015

H*

24-3/4

628

Location

Inches

Millimeters

I*

8-1/4

209

J

8

203

K

12-1/8

308

L

6

154

M

46-3/4

187

N

86-3/4

2203

O

2-7/8

74

P*

7-3/8

188

*All dimensions in the front to back direction are taken from the 1/2 inch standoffs on the front face of the unit.

Figure 16.1 Appliance Dimensions

48

Heat & Glo • Bravo • 704-902 Rev. E • 7/08

Image 48
Contents Model Bravo What to do if you smell gasCongratulations Homeowner Reference InformationTable of Contents Listing and Code Approvals Installation of Carbon Monoxide Detectors Requirements for the Commonwealth of MassachusettsInstallation to ensure maximum safety and benefit Getting StartedTools and Supplies Needed Framing and Clearances Selecting Appliance LocationConstructing the Appliance Chase ClearancesClearance to Combustibles Mantel Projections Clearances to Mantels or Combustibles above ApplianceTermination Locations Vent Termination Minimum ClearancesAlcove Applications Vent Information and Diagrams Vent Table KeyUse of Elbows Measuring StandardsVent Diagrams Top Vent Horizontal Termination One ElbowMinimum Maximum V1 Minimum H1 + H2 MaximumTop Vent Horizontal Termination Three Elbows V1 + V2 Minimum H1 + H2 MaximumTop Vent Vertical Termination No Elbow V1 = 46 ft. Max .0 m Flue OutletV1 Minimum H1 Maximum Top Vent Vertical Termination H1 + H2Vent Clearances and Framing Pipe Clearances to CombustiblesWall Penetration Framing Combustible Wall PenetrationInstalling the Ceiling Firestop Installing Attic ShieldVertical Penetration Framing Appliance Preparation Securing and Leveling the ApplianceInstalling Vent Pipe Assembly of Vent Sections DVP PipeAttaching Vent to the Firebox Assembly Assembling Pipe SectionsAssembling Minimum Installations MI Sections Assembling DVP-12A Slip SectionsDisassembly of Vent Sections Securing the Vent Sections Vertical SectionsHorizontal Sections Installing Heat Shield and Horizontal Termination Cap Installing the Horizontal Termination CapHeat Shield Requirements for Horizontal Termination Installing Roof Flashing and Vertical Ter- mination Cap 13 Minimum Height from Roof to LowestAssembling and Installing Storm Collar 17 Assembling the Storm Collar Around the PipeGas Information Fuel Conversions Gas ConnectionGas Pressures High Altitude Installations Recommendation for Wire Connecting to the ApplianceIntellifire Ignition System Wiring Wall Switch RequiredLOW Voltage See Note Junction Box Installation GRN wire Ground attached To GRN screw with Inside boxFinishing Facing MaterialFinishing Styles Option a Flush Wall FinishOption B Kiva-style Arch Option C Southwestern kiva-style Flush wall installation with Luxor Surround Option D Flush Wall Finish with Luxor SurroundAppliance Setup Clean the ApplianceAccessories Lava Rock and Ember PlacementLog Assembly LOGS-BRAVO Positioning the LogsRight Grate Tine LOG #6 Glass Assembly Air Shutter SettingsRemoving Glass Assembly Replacing Glass AssemblyOperating Instructions Before Lighting ApplianceLighting Appliance Intellifire IgnitionFrequently Asked Questions Initial Break-in ProcedureAfter Appliance is Lit Troubleshooting Intellifire Ignition SystemSympton Possible Cause Corrective Action Symptom Possible Cause Corrective Action Maintenance Tasks Maintaining and Servicing ApplianceInspect Maintenance Tasks Recommend addition of screen if one is not presentAppliance Dimension Diagram Reference MaterialsVent Components Diagrams P 4 5 4 5 E lb o wDVP-TRAP1 DVP-TRAPK2 DVP-TRAP2 DVP-TRAPK1 DVP and SL Series Components DVP-HSM-BDVP-HRC, DVP-HRC-SS Not Approved for ALL Units Log Set Assembly Service Parts ListStocked At DepotIntermittent Pilot Ignition Limited Lifetime Warranty Limited Lifetime Warranty Heat & GLO GAS Appliance ProductsContact Information Do not Discard this Manual