Heat & Glo LifeStyle 704-902 owner manual After Appliance is Lit, Frequently Asked Questions

Page 43

C. After Appliance is Lit

Initial Break-in Procedure

When you light the appliance, you may notice that it pro- duces heat which does have an associated odor or smell. If you feel this odor is excessive it may require the initial three to four hour continuous burn on high followed by a second burn up to 12 hours to fully drive off any odor from paint and lubricants used in the manufacturing process. Condensation of the glass is normal.

Note: The appliance should be run three to four hours on the initial start-up. Turn it off and let it cool completely. Remove and clean the glass. Replace the glass and run the appliance for an additional 12 hours. This will help to cure the products used in the paint and logs.

During this break-in period it is recommended that some windows in the house be opened for air circulation. This will help avoid setting off smoke detectors, and help eliminate any odors associated with the appliance’s initial burning.

WARNING

Fire Risk.

High Temperatures.

Keep combustible household items away from appliance. Do NOT obstruct combustion and ventilation air.

Do NOT place combustible items on top of or in front of appliance.

Keep furniture, draperies away from appliance.

CAUTION

Prevent accidental appliance operation when not attended.

Unplug or remove batteries from remote control if absent or if appliance will not be used for an extended period of time.

Property damage possible from elevated temperatures.

CAUTION

Smoke and odors released during initial operation.

Open windows for air circulation.

Leave room during initial operation.

Smoke may set off smoke detectors.

Smoke and odors may be irritating to sensitive individuals.

WARNING

Fire Hazard.

Keep combustible materials, gasoline and other flammable vapors and liquids clear of appliance.

Do NOT store flammable materials in the appliance’s vicinity.

Do NOT use gasoline, lantern fuel, kerosene, charcoal lighter fluid or similar liquids in this appliance.

Combustible materials may ignite.

D. Frequently Asked Questions

ISSUE

SOLUTIONS

 

 

Condensation of the glass

This is a result of gas combustion and temperature variations. As the appliance warms, this

condensation will disappear.

 

 

 

Blue flames

This is a result of normal operation and the flames will begin to yellow as the appliance is al-

lowed to burn for 20 to 40 minutes.

 

 

 

 

When first operated, this appliance may release an odor for the first several hours. This is

Odor from appliance

caused by the curing of the paint and the burning off of any oils remaining from manufactur-

ing. Odor may also be released from finishing materials and adhesives used around the

 

 

appliance.

 

 

Film on the glass

This is a normal result of the curing process of the paint and logs. Glass should be cleaned

within 3 to 4 hours of initial burning to remove deposits left by oils from the manufacturing

 

process. A non-abrasive cleaner such as gas fireplace glass cleaner may be necessary. See

 

your dealer.

 

 

 

Noise is caused by metal expanding and contracting as it heats up and cools down, similar to

Metallic noise

the sound produced by a furnace or heating duct. This noise does not affect the operation or

 

longevity of the appliance.

 

 

Is it normal to see the pilot flame burn

In an Intellifire ignition system it is normal to see the pilot flame, but it should turn off when

continually?

ON/OFF is turned off. In a standing pilot system the pilot will always stay on.

 

 

Heat & Glo • Bravo • 704-902 Rev. E • 7/08

43

Image 43
Contents What to do if you smell gas Model BravoHomeowner Reference Information CongratulationsTable of Contents Listing and Code Approvals Requirements for the Commonwealth of Massachusetts Installation of Carbon Monoxide DetectorsGetting Started Installation to ensure maximum safety and benefitTools and Supplies Needed Selecting Appliance Location Framing and ClearancesClearances Constructing the Appliance ChaseClearance to Combustibles Clearances to Mantels or Combustibles above Appliance Mantel ProjectionsVent Termination Minimum Clearances Termination LocationsAlcove Applications Measuring Standards Vent Information and DiagramsVent Table Key Use of ElbowsV1 Minimum H1 + H2 Maximum Vent DiagramsTop Vent Horizontal Termination One Elbow Minimum MaximumV1 + V2 Minimum H1 + H2 Maximum Top Vent Horizontal Termination Three ElbowsFlue Outlet Top Vent Vertical Termination No Elbow V1 = 46 ft. Max .0 mV1 Minimum H1 Maximum H1 + H2 Top Vent Vertical TerminationCombustible Wall Penetration Vent Clearances and FramingPipe Clearances to Combustibles Wall Penetration FramingInstalling Attic Shield Installing the Ceiling FirestopVertical Penetration Framing Securing and Leveling the Appliance Appliance PreparationAssembling Pipe Sections Installing Vent PipeAssembly of Vent Sections DVP Pipe Attaching Vent to the Firebox AssemblyAssembling DVP-12A Slip Sections Assembling Minimum Installations MI SectionsSecuring the Vent Sections Vertical Sections Disassembly of Vent SectionsHorizontal Sections Installing the Horizontal Termination Cap Installing Heat Shield and Horizontal Termination CapHeat Shield Requirements for Horizontal Termination 13 Minimum Height from Roof to Lowest Installing Roof Flashing and Vertical Ter- mination Cap17 Assembling the Storm Collar Around the Pipe Assembling and Installing Storm CollarFuel Conversions Gas Connection Gas InformationGas Pressures High Altitude Installations Wall Switch Required Recommendation for WireConnecting to the Appliance Intellifire Ignition System WiringLOW Voltage See Note GRN wire Ground attached To GRN screw with Inside box Junction Box InstallationFacing Material FinishingOption a Flush Wall Finish Finishing StylesOption B Kiva-style Arch Option C Southwestern kiva-style Option D Flush Wall Finish with Luxor Surround Flush wall installation with Luxor SurroundLava Rock and Ember Placement Appliance SetupClean the Appliance AccessoriesPositioning the Logs Log Assembly LOGS-BRAVORight Grate Tine LOG #6 Replacing Glass Assembly Glass AssemblyAir Shutter Settings Removing Glass AssemblyBefore Lighting Appliance Operating InstructionsIntellifire Ignition Lighting ApplianceInitial Break-in Procedure Frequently Asked QuestionsAfter Appliance is Lit Intellifire Ignition System TroubleshootingSympton Possible Cause Corrective Action Symptom Possible Cause Corrective Action Maintaining and Servicing Appliance Maintenance TasksRecommend addition of screen if one is not present Inspect Maintenance TasksReference Materials Appliance Dimension DiagramP 4 5 4 5 E lb o w Vent Components DiagramsDVP-TRAP1 DVP-TRAPK2 DVP-TRAP2 DVP-TRAPK1 DVP-HSM-B DVP and SL Series ComponentsDVP-HRC, DVP-HRC-SS Not Approved for ALL Units Service Parts List Log Set AssemblyAt Depot StockedIntermittent Pilot Ignition Limited Lifetime Warranty Heat & GLO GAS Appliance Products Limited Lifetime WarrantyDo not Discard this Manual Contact Information

704-902 specifications

The Heat & Glo LifeStyle 704-902 is a modern gas fireplace that exemplifies the marriage of cutting-edge technology and aesthetic design, making it a popular choice for homeowners looking to enhance their living spaces with warmth and style. This fireplace is particularly noted for its versatility and the ambiance it creates, turning any room into a cozy retreat.

One of the standout features of the LifeStyle 704-902 is its contemporary design, which often includes a clean and sleek look that can fit seamlessly into various home décor styles. It offers customizable trim options, allowing homeowners to personalize the fireplace to match their interiors perfectly. The large viewing area permits a panoramic view of the flame, creating an inviting focal point in the room.

Equipped with innovative technologies, the LifeStyle 704-902 ensures efficient heat distribution and energy consumption. The fireplace features a direct vent system, which uses outside air for combustion and expels exhaust gases outside, making it a safe and efficient option for heating. This system not only enhances safety but also provides improved indoor air quality.

The product is designed for user convenience, featuring easy-to-use controls, allowing homeowners to adjust the flame height and heat output effortlessly. The IntelliFire® ignition system is particularly noteworthy, as it provides reliable start-ups and can be operated with a remote control or mobile app, offering flexibility and ease of use.

In terms of efficiency, the Heat & Glo LifeStyle 704-902 excels with high Annual Fuel Utilization Efficiency (AFUE) ratings. This means that it converts a significant portion of the fuel it uses into usable heat, delivering optimal performance while keeping utility costs in check. Additionally, the fireplace can be equipped with optional fan kits that enhance air circulation, further increasing its heating capabilities.

Another characteristic of the LifeStyle 704-902 is its variety of decorative media options, such as logs, stones, and glass, which allow owners to customize the look of the firebox. This versatility ensures that the fireplace can adapt to individual tastes, making it a perfect addition to any home.

In summary, the Heat & Glo LifeStyle 704-902 combines modern aesthetics, innovative technologies, and customizable features to deliver an exceptional heating solution. Its efficiency, ease of use, and design flexibility make it a leading choice for those seeking comfort and style in their homes.