Heat & Glo LifeStyle 6000XLSB manual Continue Adding Vent Components, To Install the Heat Shield

Page 13

2. Continue Adding Vent Components

!WARNING: INSTALLATION OF THE 7000XLS FIREPLACE REQUIRES THE USE OF HEAT

SHIELD 570-290 ABOVE THE FIRST 900 ELBOW IN THE VENTING SYSTEM THAT MAKES A TRANSI- TION FROM VERTICAL TO HORIZONTAL. (HEAT SHIELD NOT REQUIRED FOR 6000XLSB).

To Install the Heat Shield:

1.Determine if the heat shield is required. Do so by mea- suring the vertical distance between the top horizontal surface of the elbow to any combustible surface above. If the distance is more than 4 inches, the heat shield is NOT required. If it is 4 inches or less, the heat shield IS REQUIRED. Install per the following steps. See Figure 11.

2.Fasten the shield in place using the four pilot holes pro- vided in the part. The shield should be oriented such that the 13 1/8 inch dimension (longest dimension) is run- ning in the same direction the elbow is pointing. The shield should be centered directly above the elbow, and positioned so that it creates a 1/2 inch airspace between the shield and the combustible surface. See Figure 12.

Continue adding vent components, locking each succeed- ing component into place.

Ensure that each succeeding vent component is secure- ly fitted and locked into the preceding component in the vent system.

90° elbows may be installed and rotated to any point around the preceding component’s vertical axis. If an el- bow does not end up in a locked position with the pre- ceding component, attach with a minimum of two (2) sheet metal screws.

 

Figure 13. Adding Venting Components

 

3. Install Support Brackets

 

For Horizontal Runs - The vent system must be supported

 

every five (5) feet of horizontal run by a horizontal pipe support.

 

To install support brackets for horizontal runs:

 

• Place the pipe supports around the vent pipe.

Figure 11

• Nail the pipe supports to the framing members.

 

CORRECT

INCORRECT

Figure 12

17

Image 13
Contents What to do if you smell gas Installers GuideSafety and Warning Information Table of Contents Installation Codes High Altitude InstallationsAppliance Certification CertificationIntroducing the Heat-N-Glo Gas Fireplaces Pre-install PreparationANY Such Action MAY Possibly Cause a Fire Hazard Diagram of the 7000XLS and 6000XLSB Locating the Fireplace Fireplace Dimensions, LocationsFraming the Fireplace Space Requirements Clearance Requirements32 156mm Identifying Vent Components Installing the Vent SystemVent System Approvals Vent System Components and Termination Kits Venting with ONE 1 90 Elbow Venting with three 90 elbows Venting with Three 3 90 ElbowsAttach the First Vent Component to the Starting Collars Installing Vent ComponentsInstall Support Brackets To Install the Heat ShieldTo install support brackets for horizontal runs Continue Adding Vent Components12 Hole and Vent Pipe Attic Firestop Ceiling Firestop Ceiling SidePointing UP Vent TerminationMinimum for vinyl clad soffits =VENT Terminal =AIR Supply InletMinimum Height from Roof to Lowest Discharge Opening Gas Control System Positioning, Leveling, and Securing the FireplaceSecuring of a Fireplace Standing Pilot Ignition SystemGas Pressure Requirements Gas Supply LineTo Check for GAS Leaks For Standing Pilot Ignition Wiring Appliance Requirements Wiring the FireplaceOptional Accessories Remote Wall SwitchHearth Extensions FinishingCeramic Installing Trim, Logs, and Ember MaterialDouble-check for faulty components After the InstallationBefore Lighting the Fireplace Lighting the FireplaceImportant Turn OFF the GAS Before Servicing Your Fireplace Fireplace Maintenance