Heat & Glo LifeStyle 6000XLSB, 7000XLS manual Positioning, Leveling, and Securing the Fireplace

Page 19

Step 4. Positioning, Leveling, and Securing the Fireplace

The diagram below shows how to properly position, level, and secure the fireplace.

Figure 23. Proper Positioning, Leveling, and

Securing of a Fireplace

Place the fireplace into position.

Level the fireplace from side to side and from front to back.

Shim the fireplace with non-combustible material, such as sheet metal, as necessary.

Secure the fireplace to the framing by nailing or screwing.

Step 5. The Gas Control System

!WARNING: THIS UNIT IS NOT FOR USE WITH SOLID FUEL.

The type of gas control system used with this model is Stand- ing Pilot Ignition.

Standing Pilot Ignition System

This system includes millivolt control valve, standing pilot, thermopile/thermocouple flame sensor, and piezo ignitor.

!WARNING: 110-120 VAC MUST NEVER BE CONNECTED TO A CONTROL VALVE IN A MILLIVOLT SYSTEM.

 

STANDING PILOT

Figure 24.

Gas Control System

23

Image 19
Contents What to do if you smell gas Installers GuideSafety and Warning Information Table of Contents Certification High Altitude InstallationsInstallation Codes Appliance CertificationIntroducing the Heat-N-Glo Gas Fireplaces Pre-install PreparationANY Such Action MAY Possibly Cause a Fire Hazard Diagram of the 7000XLS and 6000XLSB Space Requirements Clearance Requirements Fireplace Dimensions, LocationsLocating the Fireplace Framing the Fireplace32 156mm Vent System Components and Termination Kits Installing the Vent SystemIdentifying Vent Components Vent System ApprovalsVenting with ONE 1 90 Elbow Venting with three 90 elbows Venting with Three 3 90 ElbowsAttach the First Vent Component to the Starting Collars Installing Vent ComponentsContinue Adding Vent Components To Install the Heat ShieldInstall Support Brackets To install support brackets for horizontal runs12 Hole and Vent Pipe Attic Firestop Ceiling Firestop Ceiling Side Pointing UP Vent TerminationMinimum for vinyl clad soffits =VENT Terminal =AIR Supply InletMinimum Height from Roof to Lowest Discharge Opening Standing Pilot Ignition System Positioning, Leveling, and Securing the FireplaceGas Control System Securing of a FireplaceGas Pressure Requirements Gas Supply LineTo Check for GAS Leaks Remote Wall Switch Wiring the FireplaceFor Standing Pilot Ignition Wiring Appliance Requirements Optional AccessoriesHearth Extensions FinishingCeramic Installing Trim, Logs, and Ember MaterialLighting the Fireplace After the InstallationDouble-check for faulty components Before Lighting the FireplaceImportant Turn OFF the GAS Before Servicing Your Fireplace Fireplace Maintenance