Honeywell IFS-2600 installation manual Overview

Page 10

Page 6

IFS-2600Installation & Programming Manual

OVERVIEW

IFS-2600 Fire Indicator Panel (FIP) is designed to provide simplicity to the end user. The FIP uses both a liquid crystal display and conventional LED displays for fast and accurate display of system status and changing events.

A custom designed membrane keypad is used together with the liquid crystal display and LED indicators to provide fast, efficient and simple modes of operation. The keypad also provides the required flexibility for the programming of the many user configurable options of this FIP. The FIP can be configured on-site without the need of expensive programmers or components.

A serial printer can also be connected if required. The printer can be used to output programming information for ease of modification, for safekeeping and to assist in the commissioning of the installation.

IFS-2600 uses serial chain mimic outputs which significantly saves time and costs of cabling to mimic panels.

A door holder power supply (using optional transformer) is incorporated into the system for the release of smoke and fire doors on alarm.

IFS-2600 is available in a standard 8-zone configuration and can be expandable to its fully expanded state as required. The IFS-2600 in its fully expanded state can;

Monitor 64 detection zones

Control 64 optional "mapped" relay outputs

Output to a serial printer

Output serially to a mimic panel

Control to door holders

Interface as required to any Australian Fire Brigade

IFS-2600 has been designed to be functional, flexible and reliable whilst maintaining a user-friendly interface.

CAUTION

IFS-2600 FIP has been tested and approved to AS4428.1 and meets the requirements of AS1670 and AS1668 Parts 1 & 2.

However, the equipment must be correctly programmed and installed to suit the specific application. Please ensure correct operational parameters are set prior to commissioning. If further details on programming options are required, please consult the programming manual or contact our helpful technical support personnel.

WARNING:

This equipment may radiate radio frequency energy. It may also be affected by radio frequency energy and, if not installed and operated in accordance with the manufacturers instructions, may cause interference to radio communications. It has been tested and found to comply with the Class A radiated and conducted EMI requirements of AS/NZ 3548:1995 (including Amendments 1 & 2) as well as the EMI susceptibility requirements of Clause C3.5 in AS4428.0:1997

CAUTION: Radio communication devices should not be used in the vicinity of fire panels or associated ancillary devices and systems

P/N 10069 ECN08-0066

Image 10
Contents IFS-2600 Page Installation Precautions Documentation Feedback Table of Contents Instructions to Operators Placing Into OperationProgramming Appendix C Appendix aAppendix B Appendix DAppendix H Appendix FAppendix G AppendixCompatible Detectors Overview Environmental Limits SpecificationApprovals VDCAdditional relay outputs Internal 27.3V DC 1.5A Battery Charger Power Supply Ratings and SettingsInternal 24 VDC nom 3.0A Main Power Supply Internal 5VDC 2A Power SupplyBattery Type and Capacities External 27VDC Power SupplyTransient Suppression Technical DescriptionGeneral Current ConsumptionAZF Supervisory Current Zone Overload Self ResetAZF Description Overload ProtectionProgramming by Computer Printer OutputCable Connection DB9 Female DB25 Male DB9 MaleNON Adjustable Test Points Alignment and AdjustmentPCB2006 Power Supply Board PCB2005 Termination BoardAlarm Threshold Comparator TP7 Fault Threshold Comparator TP6Configuration Jumpers Placing Into Operation Initial ChecklistEquipment AS Fitted Power UP Checklist Functional TestingFault Correction Date Fault RecordTests Satisfactorily Completed Indicators Instructions to OperatorsOperator Instructions Suggested Alarm ProcedureReset Acknowledge ACKBell Isolate EXT Bell Battery Test Batt TestAuto Test Mode Warn SYS IsolateACF Reset Walk Test ModeACF Isolate Alarm Test ENT Zone FunctionsFault Test Enter Reset Enter Isolate EnterGlobal Options ProgrammingZone Options Output Relay Options Previous → Program ModeSelect → Global Main MenuRelays PrintSelect Zone # Exit Programming ModeZone Programming Zone SelectedSelect Relay # Relay Programming ModeZone Output Configuration Relay SelectedRelay Mapping Global ProgrammingRelay Type Relay #ALL Type GeneralAVF ACF OutputRelay Global Relay Unity MAP Print Programming Data Time Date & TimeLatching Type Description of Alarm Zone TypesAppendix a NON Latching TypeTime Delay AZF Zone Output Configurations Appendix BAppendix C Alarm Verification Facility AVFAVF Timeout Global Programmable OptionsAncillary Trip ACF Appendix DAncillary Trip ACF NON-LATCHING ND Latching ND NON-LATCHING NE LatchingneRelay Output Mapping Fault MappingAppendix E MappingFAULT/ISOLATE Mapping Isolate MappingAppendix F Glossary of TermsAppendix G Summary of Terminations and CautionsDoor Holder AC Input BatteryOutput Relays Appendix H IFS-2600 Programmed OptionsZone Type Programming 48IFS-2600Installation & Programming Manual Zone Output Programming Indicate IBG Ibga Bell General ACF BR1 BR2 BR1&BR2 Relay Output Mapping Mapping RLY ISO ACF BR1 BR2 FLT Mains GEN Bell Technical Drawings AppendixMain Keypad and Display Expansion Display Block Connection Diagram 12V BatterySystem Sensor Conventional Detector Connection Diagram DET B DET C RIP Hochiki Conventional Detector Connection DiagramDET a DET a DET B DET CAncillary Connection Diagram Strobe UsedTermination ASE Connection DiagramASE Bracket Auto Changeover Dual Sounder Connection Diagram Changeover from Alert to EvacAuto Change Over Dual Sounder Connection Diagram Manual ChangeoverFitted with IFS2600 Mimic Driver Mimic Connection DiagramZones MIM/EXT/26FAN Termination Board AUX Power Single Fan Connection DiagramFront Panel Control Dual Fan Connection Diagram FANExhaust Fan Connection Diagram Stops the FAN From FIPSupply Fan Connection Diagram FAN Termination BoardSmoke Spill Fan Connection Diagram From FIP Front Panel Control10W Evac Connection Diagram Sound10W Evac Slave Connection Diagram From Slave30W Evac Connection Diagram AC230W Evac Slave Connection Diagram Acinput50W Evac 50W Evac Connection DiagramPCB 50W Evac Slave Connection Diagram FAN 50W EvacPage Page Page New South Wales Queensland Victoria Head Office

IFS-2600 specifications

The Honeywell IFS-2600 is a cutting-edge portable data collection device that has gained recognition for its robustness and efficiency in various industrial settings. Designed to enhance productivity in rugged environments, the IFS-2600 is a powerful tool for data acquisition and operational optimization.

One of the key features of the Honeywell IFS-2600 is its advanced scanning technology. It is equipped with a superior imaging engine that provides high-speed scanning capabilities. This makes it ideal for scanning barcodes, even in challenging conditions. The ability to read both 1D and 2D barcodes ensures versatility in applications ranging from inventory management to shipping and receiving.

Another significant characteristic of the IFS-2600 is its rugged design. Built to withstand harsh conditions, this device is compliant with military-grade specifications and offers an impressive drop resistance. It is capable of enduring extreme temperatures, humidity, and dust, making it suitable for use in warehouses, manufacturing plants, and outdoor environments.

The IFS-2600 also boasts a user-friendly interface. Featuring a high-resolution display with touchscreen capabilities, users can easily navigate through applications and access necessary data. The device is designed for efficiency, allowing users to efficiently input information and manage tasks.

Connectivity is another prominent aspect of the Honeywell IFS-2600. With support for multiple communication protocols, including Wi-Fi, Bluetooth, and cellular options, the device ensures seamless integration into existing workflows. This connectivity allows real-time data transmission to central systems, enhancing decision-making capabilities and operational oversight.

Battery life is crucial for a portable device, and the IFS-2600 does not disappoint. It is equipped with a high-capacity battery that supports prolonged usage without frequent recharging. This makes the device perfect for long shifts, ensuring that employees can continue working without interruptions.

In summary, the Honeywell IFS-2600 is a formidable solution for businesses aiming to improve their operational efficiency through advanced data collection. With its robust scanning technology, rugged design, user-friendly interface, versatile connectivity options, and long-lasting battery life, it equips organizations with the tools necessary to thrive in an increasingly competitive market. This makes it an invaluable asset for industries such as logistics, manufacturing, and retail.