Honeywell IFS-2600 installation manual Program Mode, Previous →, Select →

Page 33

IFS-2600Installation & Programming Manual

Page 29

PROGRAM MODE

Press the following buttons in order shown to enter programming mode.

PREVIOUS

NEXT

SELECT

EXIT

ENTER

PROGRAMMING MODE

The liquid crystal display will display all messages and prompts required to program the 2600.

ONLY the "PREVIOUS","NEXT","SELECT","EXIT" AND "ENTER" keys are used in programming mode. All other keys will give an error beep and are ignored.

Alarm detection is not affected during the programming function but you must exit programming mode if any other panel functions are to be performed including acknowledge and reset of alarms.

Note: Refer to appendices for detailed explanation of functions

PROGRAMMING HIERARCHY

EXIT

SAVE CHANGES

YES

NO

ZONESRELAY

GLOBALPRINT

ZONES

TYPE

STD LATCHING

STANDARD LATCHING AVF

NON LATCH

NON LATCH 20S

TIME DELAY 10S

TIME DELAY 20S

TIME DELAY 30S

TIME DELAY 40S

TIME DELAY 50S

TIME DELAY 60S

OUTPUT

INDICATE

I BELL

IB GENERAL

IBG ACF OUT

IBGA BRIGADE 1

IBGA BRIGADE 2

IBGA BRIGADE 1 & 2

P/N 10069 ECN08-0066

Image 33
Contents IFS-2600 Page Installation Precautions Documentation Feedback Table of Contents Placing Into Operation Instructions to OperatorsProgramming Appendix B Appendix aAppendix C Appendix DAppendix G Appendix FAppendix H AppendixCompatible Detectors Overview Approvals SpecificationEnvironmental Limits VDCAdditional relay outputs Internal 24 VDC nom 3.0A Main Power Supply Power Supply Ratings and SettingsInternal 27.3V DC 1.5A Battery Charger Internal 5VDC 2A Power SupplyExternal 27VDC Power Supply Battery Type and CapacitiesGeneral Technical DescriptionTransient Suppression Current ConsumptionAZF Description Zone Overload Self ResetAZF Supervisory Current Overload ProtectionCable Connection Printer OutputProgramming by Computer DB9 Female DB25 Male DB9 MalePCB2006 Power Supply Board Alignment and AdjustmentNON Adjustable Test Points PCB2005 Termination BoardFault Threshold Comparator TP6 Alarm Threshold Comparator TP7Configuration Jumpers Initial Checklist Placing Into OperationEquipment AS Fitted Functional Testing Power UP ChecklistFault Record Fault Correction DateTests Satisfactorily Completed Instructions to Operators IndicatorsReset Suggested Alarm ProcedureOperator Instructions Acknowledge ACKAuto Test Mode Battery Test Batt TestBell Isolate EXT Bell Warn SYS IsolateWalk Test Mode ACF ResetACF Isolate Zone Functions Alarm Test ENTFault Test Enter Isolate Enter Reset EnterProgramming Global OptionsZone Options Output Relay Options Program Mode Previous →Select → Relays Main MenuGlobal PrintZone Programming Exit Programming ModeSelect Zone # Zone SelectedZone Output Configuration Relay Programming ModeSelect Relay # Relay SelectedRelay Type Global ProgrammingRelay Mapping Relay #ALL Type GeneralACF Output AVFRelay Global Relay Unity MAP Time Date & Time Print Programming DataAppendix a Description of Alarm Zone TypesLatching Type NON Latching TypeTime Delay AZF Appendix B Zone Output ConfigurationsAVF Timeout Alarm Verification Facility AVFAppendix C Global Programmable OptionsAncillary Trip ACF Appendix DAncillary Trip ACF NON-LATCHING ND Latching ND NON-LATCHING NE LatchingneAppendix E Fault MappingRelay Output Mapping MappingIsolate Mapping FAULT/ISOLATE MappingGlossary of Terms Appendix FSummary of Terminations and Cautions Appendix GBattery Door Holder AC InputOutput Relays IFS-2600 Programmed Options Appendix HZone Type Programming 48IFS-2600Installation & Programming Manual Zone Output Programming Indicate IBG Ibga Bell General ACF BR1 BR2 BR1&BR2 Relay Output Mapping Mapping RLY ISO ACF BR1 BR2 FLT Mains GEN Bell Appendix Technical DrawingsMain Keypad and Display Expansion Display 12V Battery Block Connection DiagramSystem Sensor Conventional Detector Connection Diagram DET a Hochiki Conventional Detector Connection DiagramDET B DET C RIP DET a DET B DET CStrobe Used Ancillary Connection DiagramASE Connection Diagram TerminationASE Bracket Changeover from Alert to Evac Auto Changeover Dual Sounder Connection DiagramManual Changeover Auto Change Over Dual Sounder Connection DiagramZones Mimic Connection DiagramFitted with IFS2600 Mimic Driver MIM/EXT/26Single Fan Connection Diagram FAN Termination Board AUX PowerFront Panel Control FAN Dual Fan Connection DiagramStops the FAN From FIP Exhaust Fan Connection DiagramFAN Termination Board Supply Fan Connection DiagramFrom FIP Front Panel Control Smoke Spill Fan Connection DiagramSound 10W Evac Connection DiagramFrom Slave 10W Evac Slave Connection DiagramAC2 30W Evac Connection DiagramAcinput 30W Evac Slave Connection Diagram50W Evac Connection Diagram 50W EvacPCB FAN 50W Evac 50W Evac Slave Connection DiagramPage Page Page New South Wales Queensland Victoria Head Office

IFS-2600 specifications

The Honeywell IFS-2600 is a cutting-edge portable data collection device that has gained recognition for its robustness and efficiency in various industrial settings. Designed to enhance productivity in rugged environments, the IFS-2600 is a powerful tool for data acquisition and operational optimization.

One of the key features of the Honeywell IFS-2600 is its advanced scanning technology. It is equipped with a superior imaging engine that provides high-speed scanning capabilities. This makes it ideal for scanning barcodes, even in challenging conditions. The ability to read both 1D and 2D barcodes ensures versatility in applications ranging from inventory management to shipping and receiving.

Another significant characteristic of the IFS-2600 is its rugged design. Built to withstand harsh conditions, this device is compliant with military-grade specifications and offers an impressive drop resistance. It is capable of enduring extreme temperatures, humidity, and dust, making it suitable for use in warehouses, manufacturing plants, and outdoor environments.

The IFS-2600 also boasts a user-friendly interface. Featuring a high-resolution display with touchscreen capabilities, users can easily navigate through applications and access necessary data. The device is designed for efficiency, allowing users to efficiently input information and manage tasks.

Connectivity is another prominent aspect of the Honeywell IFS-2600. With support for multiple communication protocols, including Wi-Fi, Bluetooth, and cellular options, the device ensures seamless integration into existing workflows. This connectivity allows real-time data transmission to central systems, enhancing decision-making capabilities and operational oversight.

Battery life is crucial for a portable device, and the IFS-2600 does not disappoint. It is equipped with a high-capacity battery that supports prolonged usage without frequent recharging. This makes the device perfect for long shifts, ensuring that employees can continue working without interruptions.

In summary, the Honeywell IFS-2600 is a formidable solution for businesses aiming to improve their operational efficiency through advanced data collection. With its robust scanning technology, rugged design, user-friendly interface, versatile connectivity options, and long-lasting battery life, it equips organizations with the tools necessary to thrive in an increasingly competitive market. This makes it an invaluable asset for industries such as logistics, manufacturing, and retail.