Honeywell Complete IFS Diagram for Auto Changeover and Dual Sounder Connections

Page 63

IFS-2600Installation & Programming Manual

Page 59

Auto Changeover Dual Sounder Connection Diagram

1

2

3

4

A

NOTE:

NOTE:

Maximum capacity is 10 sounders

 

INSTALL LINK JP1 FOR AUTO

or 4 strobes

CHANGEOVER FROM ALERT TO EVAC

 

A

B

C

 

 

 

 

 

 

 

 

 

 

MONITORED DRIVER BOARD

 

 

 

 

 

 

 

 

 

 

 

 

IFS 993

 

 

 

 

IFS2600

 

IFS958 RELAY BOARD

 

FAULT COM

FAULT N/O

 

 

 

 

 

 

TERMINATION

 

 

 

 

 

 

 

 

 

 

 

TERM A

TERM B

PCB2004

+24V

 

 

COM

 

 

COM

 

EVAC

 

 

 

 

0V

NO

NC

NO

NC

AL

0V

+24

 

N/O

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WARN

+24

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0V

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BELL

+24

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0V

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WARN SYS EOL

 

 

 

 

 

 

 

 

 

+24

 

 

 

 

 

 

 

 

 

 

 

 

 

ACF

 

 

 

 

 

 

4K7

 

 

 

 

 

 

 

 

0V

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AUX

+24

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0V

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ALERT STROBE

EVAC STROBE

(AMBER)

(RED)

+24V

0V

+24V

0V

RED

BLACK

RED

BLACK

1K8

EOL

4

3

2

1

4

3

2

1

B

C

D

 

 

 

 

 

 

 

 

 

 

DUAL TONE AS2220

 

DUAL TONE AS2220

 

 

 

 

 

 

 

 

 

 

 

 

SOUNDER

 

 

SOUNDER

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Copyright

 

 

 

7 Columbia Court,

Sheet:

1 Of:

1

 

 

Title

IFS2600 MONITORED

 

 

 

 

 

 

This document is & shall

 

 

 

Norwest Business Park

 

 

 

 

 

 

 

 

 

Notifier Inertia Fire Systems

C

 

 

Baulkham Hills NSW 2153

Traced

23/8/05

 

Design I PERRY

 

DUAL SOUNDER

 

 

 

 

 

 

remain the property of

O

 

 

AUSTRALIA

Drawn/

 

 

Engineer

 

AUTO CHANGEOVER

 

 

 

 

 

 

Unauthorised use of this

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

document in any way is

 

 

 

Tel 61 2 9894 1444

 

I PERRY

 

 

 

 

 

 

 

 

 

 

 

Drawing File No.

 

 

 

Approved

 

 

 

 

Size

 

Drg.

2600-DUAL

Rev

B

ADDED RELAY

 

G.W.

G.W.23/1/04

prohibited.

 

 

Fax 61 2 9899 4156

This Drawing must not be used for Construction

A4

 

No.

Revision - revise on CAD. Do not amend by hand

Eng.

App. Date

=DocumentFullPathAndName

 

 

Email: support@inertia.com.au

unless signed as approved

No.

AUTO-SNDR

A

 

 

1

 

 

 

2

 

3

 

 

 

 

 

 

 

 

4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

D

P/N 10069 ECN08-0066

Image 63
Contents IFS-2600 Page Installation Precautions Documentation Feedback Table of Contents Placing Into Operation Instructions to OperatorsProgramming Appendix D Appendix aAppendix B Appendix CAppendix Appendix FAppendix G Appendix HCompatible Detectors Overview VDC SpecificationApprovals Environmental LimitsAdditional relay outputs Internal 5VDC 2A Power Supply Power Supply Ratings and SettingsInternal 24 VDC nom 3.0A Main Power Supply Internal 27.3V DC 1.5A Battery ChargerExternal 27VDC Power Supply Battery Type and CapacitiesCurrent Consumption Technical DescriptionGeneral Transient SuppressionOverload Protection Zone Overload Self ResetAZF Description AZF Supervisory CurrentDB9 Female DB25 Male DB9 Male Printer OutputCable Connection Programming by ComputerPCB2005 Termination Board Alignment and AdjustmentPCB2006 Power Supply Board NON Adjustable Test PointsFault Threshold Comparator TP6 Alarm Threshold Comparator TP7Configuration Jumpers Initial Checklist Placing Into OperationEquipment AS Fitted Functional Testing Power UP ChecklistFault Record Fault Correction DateTests Satisfactorily Completed Instructions to Operators IndicatorsAcknowledge ACK Suggested Alarm ProcedureReset Operator InstructionsWarn SYS Isolate Battery Test Batt TestAuto Test Mode Bell Isolate EXT BellWalk Test Mode ACF ResetACF Isolate Zone Functions Alarm Test ENTFault Test Enter Isolate Enter Reset EnterProgramming Global OptionsZone Options Output Relay Options Program Mode Previous →Select → Print Main MenuRelays GlobalZone Selected Exit Programming ModeZone Programming Select Zone #Relay Selected Relay Programming ModeZone Output Configuration Select Relay #Relay #ALL Type General Global ProgrammingRelay Type Relay MappingACF Output AVFRelay Global Relay Unity MAP Time Date & Time Print Programming DataNON Latching Type Description of Alarm Zone TypesAppendix a Latching TypeTime Delay AZF Appendix B Zone Output ConfigurationsGlobal Programmable Options Alarm Verification Facility AVFAVF Timeout Appendix CNON-LATCHING ND Latching ND NON-LATCHING NE Latchingne Appendix DAncillary Trip ACF Ancillary Trip ACFMapping Fault MappingAppendix E Relay Output MappingIsolate Mapping FAULT/ISOLATE MappingGlossary of Terms Appendix FSummary of Terminations and Cautions Appendix GBattery Door Holder AC InputOutput Relays IFS-2600 Programmed Options Appendix HZone Type Programming 48IFS-2600Installation & Programming Manual Zone Output Programming Indicate IBG Ibga Bell General ACF BR1 BR2 BR1&BR2 Relay Output Mapping Mapping RLY ISO ACF BR1 BR2 FLT Mains GEN Bell Appendix Technical DrawingsMain Keypad and Display Expansion Display 12V Battery Block Connection DiagramSystem Sensor Conventional Detector Connection Diagram DET a DET B DET C Hochiki Conventional Detector Connection DiagramDET a DET B DET C RIPStrobe Used Ancillary Connection DiagramASE Connection Diagram TerminationASE Bracket Changeover from Alert to Evac Auto Changeover Dual Sounder Connection DiagramManual Changeover Auto Change Over Dual Sounder Connection DiagramMIM/EXT/26 Mimic Connection DiagramZones Fitted with IFS2600 Mimic DriverSingle Fan Connection Diagram FAN Termination Board AUX PowerFront Panel Control FAN Dual Fan Connection DiagramStops the FAN From FIP Exhaust Fan Connection DiagramFAN Termination Board Supply Fan Connection DiagramFrom FIP Front Panel Control Smoke Spill Fan Connection DiagramSound 10W Evac Connection DiagramFrom Slave 10W Evac Slave Connection DiagramAC2 30W Evac Connection DiagramAcinput 30W Evac Slave Connection Diagram50W Evac Connection Diagram 50W EvacPCB FAN 50W Evac 50W Evac Slave Connection DiagramPage Page Page New South Wales Queensland Victoria Head Office

IFS-2600 specifications

The Honeywell IFS-2600 is a cutting-edge portable data collection device that has gained recognition for its robustness and efficiency in various industrial settings. Designed to enhance productivity in rugged environments, the IFS-2600 is a powerful tool for data acquisition and operational optimization.

One of the key features of the Honeywell IFS-2600 is its advanced scanning technology. It is equipped with a superior imaging engine that provides high-speed scanning capabilities. This makes it ideal for scanning barcodes, even in challenging conditions. The ability to read both 1D and 2D barcodes ensures versatility in applications ranging from inventory management to shipping and receiving.

Another significant characteristic of the IFS-2600 is its rugged design. Built to withstand harsh conditions, this device is compliant with military-grade specifications and offers an impressive drop resistance. It is capable of enduring extreme temperatures, humidity, and dust, making it suitable for use in warehouses, manufacturing plants, and outdoor environments.

The IFS-2600 also boasts a user-friendly interface. Featuring a high-resolution display with touchscreen capabilities, users can easily navigate through applications and access necessary data. The device is designed for efficiency, allowing users to efficiently input information and manage tasks.

Connectivity is another prominent aspect of the Honeywell IFS-2600. With support for multiple communication protocols, including Wi-Fi, Bluetooth, and cellular options, the device ensures seamless integration into existing workflows. This connectivity allows real-time data transmission to central systems, enhancing decision-making capabilities and operational oversight.

Battery life is crucial for a portable device, and the IFS-2600 does not disappoint. It is equipped with a high-capacity battery that supports prolonged usage without frequent recharging. This makes the device perfect for long shifts, ensuring that employees can continue working without interruptions.

In summary, the Honeywell IFS-2600 is a formidable solution for businesses aiming to improve their operational efficiency through advanced data collection. With its robust scanning technology, rugged design, user-friendly interface, versatile connectivity options, and long-lasting battery life, it equips organizations with the tools necessary to thrive in an increasingly competitive market. This makes it an invaluable asset for industries such as logistics, manufacturing, and retail.