Hearth and Home Technologies CB4236MIR, CB4842MIR Installing Vent Pipe, Assembly of Vent Sections

Page 25

10 Installing Vent Pipe

A. Assembly of Vent Sections

This B-Vent appliance requires 5 in. B-vent double-wall pipe. Follow the pipe manufacturer’s installation guide- lines when installing the unit. This will ensure proper operation and prevent safety hazards.

WARNING! Risk of Fire/Exhaust Fumes! Assemble pipe sections per B-vent manufacturer’s instructions. Use support tabs for screws. Pipe may separate if not prop- erly joined.

C. Secure Vent Sections

Secure vent sections with vent supports following B-vent manufacturer’s instructions.

WARNING! Risk of Fire or Explosion! Use vent run supports per vent manufacturer’s installation instructions.

Connect vent sections per vent manufacturer’s installation instructions.

Maintain all clearances to combustibles. Maintain specified slope (if required).

Improper support may allow vent to sag or separate.

B. Attach Vent to Firebox

Three tabs extend from appliance collar shield. Attach tabs to first section of B-vent pipe using self-tapping 1/4 in. screws supplied with appliance. See Figure 10.1.

Tabs

D. Install Attic Insulation Shield

WARNING! Fire Risk. DO NOT allow loose materials or insulation to touch vent. Hearth & Home Technologies Inc. requires the use of an attic shield.

The National Fuel Gas Code ANSI Z223.1 and NFPA 54 requires an attic shield constructed of 26 gauge minimum metal that extends at least 2 in. (51 mm) above insulation.

Attic shields must meet vent manufacturer’s specified clearance and be secured in place per vent manufactur- er’s instructions.

Figure 10.1 Attach Vent to Firebox

Heatilator • Caliber Mesh BV Series • 4040-848 Rev G • 10/08

25

Image 25
Contents Models Installation and OperationVent Gas Appliance What to do if you smell gasHomeowner Reference Information CongratulationsInstaller Guide Table of ContentsUser Guide Troubleshooting Appliance SetupReference Materials CONDITIONS, Exclusions & Limitation of Liability Warranty Hearth & Home Technologies Limited WarrantyWarranty Listing and Code Approvals Operating Instructions Gas Fireplace SafetyYour Fireplace Remote Controls, Wall Controls and Wall Switches Fixed Glass AssemblyFan Kit optional Clear SpaceLighting Instructions IPI For Your Safety Read Before LightingInitial Break-in Procedure Frequently Asked QuestionsAfter Fireplace is Lit Maintenance Tasks-Homeowner Maintenance and ServiceMaintenance Tasks-Qualified Service Technician Typical Appliance System Getting StartedTools and Supplies Needed Design and Installation ConsiderationsInspect Appliance and Components Negative Pressure Selecting Appliance Location Framing and ClearancesModel # Constructing the Appliance Chase Rough Opening Model Width Height Depth ClearancesMantels Mantel and Wall ProjectionsMantel Legs or Wall Projections Vent Termination Minimum Clearances Termination LocationsGas Termination Vent Guidelines Vent Information and DiagramsVent System Configuration Pipe Clearances to Combustibles Vent Clearances and FramingWall and Ceiling Penetration Framing Vertical Penetration FramingAppliance Preparation Install Outside Air Kit Damper AssemblyGas and Electrical Connections Secure and Level the ApplianceAssembly of Vent Sections Installing Vent PipeInstall Attic Insulation Shield Secure Vent SectionsFuel Conversion Gas InformationGas Pressure Gas ConnectionOptional Accessories Requirements Wiring RequirementsElectrical Information Wall Switch Installation for Fan Optional Junction Box InstallationFacing Material FinishingAppliance Setup Glass Assembly Install the Log AssemblyRemoving Glass Assembly Replacing Glass AssemblyInstall Clean Face Components Install TrimInstall Hood Install Top Latch CoverInstall Floor Cover Air Shutter SettingInstall Bottom Latch Cover Install Firescreen AssemblyIntellifire Ignition System TroubleshootingRange. Replace pilot if any damage is detected Reference Materials Appliance Dimension DiagramCB4236MIR Service Parts ListCB4842MIR IPI Valve Assembly Optional Components Model # Description This page intentionally left blank This page intentionally left blank Contact Information