J. Install Trim

Install optional trim kits and/or surrounds using the instructions included with the accessory.

Use non-combustible materials to cover the gap between the sheet rock and the appliance (if desired).

Do not obstruct or modify the air inlet/outlet grilles.

Leave space to lower the bottom grille and remove the trim door.

K. Install Clean Face Components

Carefully remove components from skin pack. See Fig- ure 14.9 for identification of components.

Figure 14.9 Clean Face Components/Skin Pack

Install Hood

Bend screen rod tabs down at a 90-deg. angle. See Figure 14.10.

Figure 14.10 Screen Rod Tab

Install above the glass panel.

Hood must be attached or a fire hazard may result.

Locate the four screws (for 4236) or five screws (for 4842) just inside the upper section of the appliance.

Loosen the screws, but do NOT remove.

Position hood and slide notches over screw heads, ensuring hood also slips into the clips.

Tighten the screws to hold hood firmly in place.

See Figure 14.11.

Figure 14.11 Installing the Hood

Install Top Latch Cover

Insert top latch cover over existing shoulder screws. See Figure 14.12.

Push down until the tabs lock in place.

Figure 14.12 Installing Top Latch Cover

32

Heatilator • Caliber Mesh BV Series • 4040-848 Rev G • 10/08

Image 32
Contents Installation and Operation ModelsVent Gas Appliance What to do if you smell gasCongratulations Homeowner Reference InformationUser Guide Table of ContentsInstaller Guide Reference Materials Appliance SetupTroubleshooting Warranty Hearth & Home Technologies Limited Warranty CONDITIONS, Exclusions & Limitation of LiabilityWarranty Listing and Code Approvals Your Fireplace Gas Fireplace SafetyOperating Instructions Fixed Glass Assembly Remote Controls, Wall Controls and Wall SwitchesFan Kit optional Clear SpaceFor Your Safety Read Before Lighting Lighting Instructions IPIAfter Fireplace is Lit Frequently Asked QuestionsInitial Break-in Procedure Maintenance and Service Maintenance Tasks-HomeownerMaintenance Tasks-Qualified Service Technician Getting Started Typical Appliance SystemInspect Appliance and Components Design and Installation ConsiderationsTools and Supplies Needed Negative Pressure Model # Framing and ClearancesSelecting Appliance Location Constructing the Appliance Chase Clearances Rough Opening Model Width Height DepthMantel Legs or Wall Projections Mantel and Wall ProjectionsMantels Gas Termination Termination LocationsVent Termination Minimum Clearances Vent System Configuration Vent Information and DiagramsVent Guidelines Vent Clearances and Framing Pipe Clearances to CombustiblesWall and Ceiling Penetration Framing Vertical Penetration FramingInstall Outside Air Kit Damper Assembly Appliance PreparationGas and Electrical Connections Secure and Level the ApplianceInstalling Vent Pipe Assembly of Vent SectionsInstall Attic Insulation Shield Secure Vent SectionsGas Information Fuel ConversionGas Pressure Gas ConnectionElectrical Information Wiring RequirementsOptional Accessories Requirements Junction Box Installation Wall Switch Installation for Fan OptionalFinishing Facing MaterialAppliance Setup Install the Log Assembly Glass AssemblyRemoving Glass Assembly Replacing Glass AssemblyInstall Trim Install Clean Face ComponentsInstall Hood Install Top Latch CoverAir Shutter Setting Install Floor CoverInstall Bottom Latch Cover Install Firescreen AssemblyTroubleshooting Intellifire Ignition SystemRange. Replace pilot if any damage is detected Appliance Dimension Diagram Reference MaterialsService Parts List CB4236MIRCB4842MIR IPI Valve Assembly Optional Components Model # Description This page intentionally left blank This page intentionally left blank Contact Information