Hearth and Home Technologies CB4842MIR, CB4236MIR owner manual For Your Safety Read Before Lighting

Page 10

J. Lighting Instructions (IPI)

For normal use, activate/deactivate your fireplace with the wall switch or remote control.

The IPI system may be operated with two D-cell batteries. When using batteries, unplug the transformer. To prolong battery life, remove them when using the transformer.

If your fireplace must be deactivated for serviced or an extended period of time, follow the instructions below.

FOR YOUR SAFETY READ BEFORE LIGHTING

 

WARNING:

If you do not follow these instructions exactly, a fire

 

 

 

 

 

or explosion may result causing property damage,

 

 

 

personal injury or loss of life.

 

This appliance needs fresh air for safe operation and must be installed so there are provisions for adequate combustion and ventilation air.

This appliance must be installed in accordance with local codes, if any; if not, follow ANSI Z223.1 or, in Canada, current CAN/CGA-B149.

A.This appliance is equipped with an ignition device which automatically lights the pilot. Do not try to light the pilot by hand.

B.BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS

Do not try to light any appliance.

Do not touch any electric switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions.

If you cannot reach your gas supplier, call the fire department.

C.Use only your hand to push in and move the gas control valve or turn the gas control knob. Never use tools. If the lever or knob will not move by hand, don't try to repair it, call a qualified service technician. Force or attempted repair may result in a fire or explosion.

D.Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.

This appliance must be properly connected to a venting system in accordance with the manufacturer's installation instructions.

WARNING: Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. Refer to the owner's information manual provided with the appliance. For assistance or additional information consult a qualified installer, service agency or the gas supplier.

CAUTION:

LIGHTING INSTRUCTIONS

1.

STOP! Read the safety information above on this label.

5.

Wait five minutes to clear out any gas. If you then smell gas, STOP!

2.

Turn wall switch to the "OFF" position or thermostat to the

 

Follow "B" in the safety information above on this label. If you don't

 

lowest setting.

 

smell gas, go to the next step.

3.

Turn off all electric power to the appliance.

6.

To turn on the burner, turn on all electric power to this appliance and

4.

This appliance is equipped with an ignition device which

 

turn on the wall switch or set the thermostat to the desired setting.

 

automatically lights the pilot. Do NOT try to light the pilot by

7.

If the appliance will not operate, follow the instructions "TO TURN OFF

 

hand.

 

GAS TO APPLIANCE" and call your service technician or gas supplier.

TO TURN OFF GAS TO APPLIANCE

1.

Turn off wall switch or set thermostat to lowest setting.

3.

Push the gas control lever in and move to the "OFF" position

2.

Turn off all electric power to the appliance if service is to be

 

or push the gas control lever to the "OFF" position. Do not

 

performed.

 

force.

 

 

4.

Replace the control access panel.

Due to high surface temperatures, keep children, clothing and furniture away.

Keep burner and control compartment clean. See installation and operating instructions accompanying the appliance.

33631D

Hot while in operation. Do

not touch. Keep children, clothing, furniture, gasoline and other liquids having flammable vapors away.

WARNING RISK OF FIRE

This appliance is intended to burn a specified gas fuel only. Do not attempt to use with solid wood fuel or another type of fuel. Do not attempt to modify or use any other type of gas burner system.

WARNING: Disconnect the electric power before servicing. If for any reason the original wire supplied with the appliance must be replaced, it must be replaced with 105° C or its equivalent.

For use with natural gas or propane. A conversion kit as supplied by the manufacturer shall be used to convert this appliance to the alternative fuel.

*Also certified for installation in a bedroom or a bed-sitting room.

*For U.S. only!

NATURAL GAS

10

Heatilator • Caliber Mesh BV Series • 4040-848 Rev G • 10/08

Image 10
Contents Vent Gas Appliance Installation and OperationModels What to do if you smell gasCongratulations Homeowner Reference InformationInstaller Guide Table of ContentsUser Guide Troubleshooting Appliance SetupReference Materials Warranty Hearth & Home Technologies Limited Warranty CONDITIONS, Exclusions & Limitation of LiabilityWarranty Listing and Code Approvals Operating Instructions Gas Fireplace SafetyYour Fireplace Fan Kit optional Fixed Glass AssemblyRemote Controls, Wall Controls and Wall Switches Clear SpaceFor Your Safety Read Before Lighting Lighting Instructions IPIInitial Break-in Procedure Frequently Asked QuestionsAfter Fireplace is Lit Maintenance and Service Maintenance Tasks-HomeownerMaintenance Tasks-Qualified Service Technician Getting Started Typical Appliance SystemTools and Supplies Needed Design and Installation ConsiderationsInspect Appliance and Components Negative Pressure Selecting Appliance Location Framing and ClearancesModel # Constructing the Appliance Chase Clearances Rough Opening Model Width Height DepthMantels Mantel and Wall ProjectionsMantel Legs or Wall Projections Vent Termination Minimum Clearances Termination LocationsGas Termination Vent Guidelines Vent Information and DiagramsVent System Configuration Wall and Ceiling Penetration Framing Vent Clearances and FramingPipe Clearances to Combustibles Vertical Penetration FramingGas and Electrical Connections Install Outside Air Kit Damper AssemblyAppliance Preparation Secure and Level the ApplianceInstall Attic Insulation Shield Installing Vent PipeAssembly of Vent Sections Secure Vent SectionsGas Pressure Gas InformationFuel Conversion Gas ConnectionOptional Accessories Requirements Wiring RequirementsElectrical Information Junction Box Installation Wall Switch Installation for Fan OptionalFinishing Facing MaterialAppliance Setup Removing Glass Assembly Install the Log AssemblyGlass Assembly Replacing Glass AssemblyInstall Hood Install TrimInstall Clean Face Components Install Top Latch CoverInstall Bottom Latch Cover Air Shutter SettingInstall Floor Cover Install Firescreen AssemblyTroubleshooting Intellifire Ignition SystemRange. Replace pilot if any damage is detected Appliance Dimension Diagram Reference MaterialsService Parts List CB4236MIRCB4842MIR IPI Valve Assembly Optional Components Model # Description This page intentionally left blank This page intentionally left blank Contact Information