Hearth and Home Technologies CB4236MIR, CB4842MIR owner manual Models, Vent Gas Appliance

Page 1

Owner’s Manual

Installation and Operation

Model(s):

CB4236MIR

CB4842MIR

B-Vent Gas Appliance

NOTICE

DO NOT DISCARD THIS MANUAL

• Important operating

• Read, understand and follow

• Leave this manual with

and maintenance

these instructions for safe

party responsible for use

instructions included.

installation and operation.

and operation.

D DO

NO

S

 

I

C

T

 

 

ARD

WARNING: If the information in these instructions is not followed exactly, a fire or explosion may result causing property damage, personal injury, or death.

DO NOT store or use gasoline or other flam- mable vapors and liquids in the vicinity of this or any other appliance.

What to do if you smell gas

-DO NOT try to light any appliance.

-DO NOT touch any electrical switch. DO NOT use any phone in your building.

-Immediately call your gas supplier from a neighbor’s phone. Follow the gas suppli- er’s instructions.

-If you cannot reach your gas supplier, call the fire department.

Installation and service must be performed by a qualified installer, service agency, or the gas supplier.

This appliance may be installed as an OEM installation in manufactured home (USA only) or mobile home and must be installed in accordance with the manufacturer’s instructions and the manufactured home construction and safety standard, Title 24 CFR, Part 3280 or Standard for

Installation in Mobile Homes, CAN/CSA Z240MH.

This appliance is only for use with the type(s) of gas indicated on the rating plate.

WARNING

HOT SURFACES!

Glass and other surfaces are hot during operation AND cool down.

Hot glass will cause burns.

DO NOT touch glass until it is cooled

• NEVER allow children to touch glass

Keep children away

CAREFULLY SUPERVISE children in same room as fireplace.

Alert children and adults to hazards of high temperatures.

High temperatures may ignite clothing or other flammable materials.

Keep clothing, furniture, draperies and other flammable materials away.

This appliance has been supplied with an integral barrier to prevent direct contact with the fixed glass panel. DO NOT operate the appliance with the barrier removed.

Contact your dealer or Hearth & Home Technologies if the barrier is not present or help is needed to properly install one.

In the Commonwealth of Massachusetts installation must be performed by a licensed plumber or gas fitter.

A CO detector shall be installed in the room where the appliance in installed.

Installation and service of this appliance should be performed by qualified personnel. Hearth & Home Technologies suggests NFI certified or factory trained professionals, or technicians supervised by an NFI certified professional.

Heatilator • Caliber Mesh BV Series • 4040-848 Rev G • 10/08

1

Image 1
Contents Models Installation and OperationVent Gas Appliance What to do if you smell gasHomeowner Reference Information CongratulationsInstaller Guide Table of ContentsUser Guide Troubleshooting Appliance SetupReference Materials CONDITIONS, Exclusions & Limitation of Liability Warranty Hearth & Home Technologies Limited WarrantyWarranty Listing and Code Approvals Operating Instructions Gas Fireplace SafetyYour Fireplace Remote Controls, Wall Controls and Wall Switches Fixed Glass AssemblyFan Kit optional Clear SpaceLighting Instructions IPI For Your Safety Read Before LightingInitial Break-in Procedure Frequently Asked QuestionsAfter Fireplace is Lit Maintenance Tasks-Homeowner Maintenance and ServiceMaintenance Tasks-Qualified Service Technician Typical Appliance System Getting StartedTools and Supplies Needed Design and Installation ConsiderationsInspect Appliance and Components Negative Pressure Selecting Appliance Location Framing and ClearancesModel # Constructing the Appliance Chase Rough Opening Model Width Height Depth ClearancesMantels Mantel and Wall ProjectionsMantel Legs or Wall Projections Vent Termination Minimum Clearances Termination LocationsGas Termination Vent Guidelines Vent Information and DiagramsVent System Configuration Pipe Clearances to Combustibles Vent Clearances and FramingWall and Ceiling Penetration Framing Vertical Penetration FramingAppliance Preparation Install Outside Air Kit Damper AssemblyGas and Electrical Connections Secure and Level the ApplianceAssembly of Vent Sections Installing Vent PipeInstall Attic Insulation Shield Secure Vent SectionsFuel Conversion Gas InformationGas Pressure Gas ConnectionOptional Accessories Requirements Wiring RequirementsElectrical Information Wall Switch Installation for Fan Optional Junction Box InstallationFacing Material FinishingAppliance Setup Glass Assembly Install the Log AssemblyRemoving Glass Assembly Replacing Glass AssemblyInstall Clean Face Components Install TrimInstall Hood Install Top Latch CoverInstall Floor Cover Air Shutter SettingInstall Bottom Latch Cover Install Firescreen AssemblyIntellifire Ignition System TroubleshootingRange. Replace pilot if any damage is detected Reference Materials Appliance Dimension DiagramCB4236MIR Service Parts ListCB4842MIR IPI Valve Assembly Optional Components Model # Description This page intentionally left blank This page intentionally left blank Contact Information