H. Install the Log Assembly

Base logs have been permanently mounted on the grate assembly and should not be moved. See Figure 14.5.

Figure 14.5 Base Logs

Install “Y” log on left hand side of grate using locating pins to position. See Figure 14.6.

Figure 14.6 Placing Left Top Log

Install right top log as shown in Figure 14.7 using locating pins to position log properly.

Figure 14.7 Placing Right Top Log

I. Glass Assembly

WARNING! Risk of Asphyxiation! Handle fixed glass assembly with care. Inspect the gasket to ensure it is undamaged and inspect the glass for cracks, chips or scratches.

DO NOT strike, slam or scratch glass.

DO NOT operate fireplace with glass removed, cracked, broken or scratched.

Replace as a complete assembly.

Removing Glass Assembly

Remove mesh firescreen (refer to Figure 14.15).

Lift and pull the upper latch cover towards you to expose the two (36 in. model) or three (42 in. model) glass latches.

Lift and pull lower latch cover to expose the two (36 in. model) or three (42 in. model) glass latches.

Rotate the bottom of the screen assembly away from the appliance and lower out of the top retainers.

Release the top and bottom access latches and rotate the top of the glass assembly away from the top of the appliance.

Place the glass assembly on a surface that will not scratch the surface of the glass assembly.

Latches

(both bottom

and top)

Glass

Assembly

Figure 14.8 Fixed Glass Assembly

Replacing Glass Assembly

Replace the glass assembly on the lower access latches.

Rotate the upper portion of the glass assembly into place.

Engage the top access latches.

Engage the lower access latches.

Reinstall upper latch cover (see Figure 14.12).

Reinstall lower latch cover (see Figure 14.14).

Reinstall mesh firescreen (see Figure 14.15).

Heatilator • Caliber Mesh BV Series • 4040-848 Rev G • 10/08

31

Image 31
Contents What to do if you smell gas Installation and OperationModels Vent Gas ApplianceHomeowner Reference Information CongratulationsInstaller Guide Table of ContentsUser Guide Troubleshooting Appliance SetupReference Materials CONDITIONS, Exclusions & Limitation of Liability Warranty Hearth & Home Technologies Limited WarrantyWarranty Listing and Code Approvals Operating Instructions Gas Fireplace SafetyYour Fireplace Clear Space Fixed Glass AssemblyRemote Controls, Wall Controls and Wall Switches Fan Kit optionalLighting Instructions IPI For Your Safety Read Before LightingInitial Break-in Procedure Frequently Asked QuestionsAfter Fireplace is Lit Maintenance Tasks-Homeowner Maintenance and ServiceMaintenance Tasks-Qualified Service Technician Typical Appliance System Getting StartedTools and Supplies Needed Design and Installation ConsiderationsInspect Appliance and Components Negative Pressure Selecting Appliance Location Framing and ClearancesModel # Constructing the Appliance Chase Rough Opening Model Width Height Depth ClearancesMantels Mantel and Wall ProjectionsMantel Legs or Wall Projections Vent Termination Minimum Clearances Termination LocationsGas Termination Vent Guidelines Vent Information and DiagramsVent System Configuration Vertical Penetration Framing Vent Clearances and FramingPipe Clearances to Combustibles Wall and Ceiling Penetration FramingSecure and Level the Appliance Install Outside Air Kit Damper AssemblyAppliance Preparation Gas and Electrical ConnectionsSecure Vent Sections Installing Vent PipeAssembly of Vent Sections Install Attic Insulation ShieldGas Connection Gas InformationFuel Conversion Gas PressureOptional Accessories Requirements Wiring RequirementsElectrical Information Wall Switch Installation for Fan Optional Junction Box InstallationFacing Material FinishingAppliance Setup Replacing Glass Assembly Install the Log AssemblyGlass Assembly Removing Glass AssemblyInstall Top Latch Cover Install TrimInstall Clean Face Components Install HoodInstall Firescreen Assembly Air Shutter SettingInstall Floor Cover Install Bottom Latch CoverIntellifire Ignition System TroubleshootingRange. Replace pilot if any damage is detected Reference Materials Appliance Dimension DiagramCB4236MIR Service Parts ListCB4842MIR IPI Valve Assembly Optional Components Model # Description This page intentionally left blank This page intentionally left blank Contact Information