Hearth and Home Technologies GDST3831I Two Elbows Three Elbows, Minimum Maximum + V 2 Min

Page 30

Two Elbows

V2

H1

Figure 7.9

Three Elbows

V2

H2

V1 Minimum

H Maximum

 

V2

V1 + V2 Min.

90 Elbow

1-1/2 ft.

 

457 mm

 

*

*

1/2 ft.

152 mm

2 ft.

 

610 mm

 

*

*

1-1/2 ft.

457 mm

3 ft.

 

914 mm

 

*

*

 

 

 

 

 

 

 

 

2-1/2 ft.

762 mm

5 ft.

 

1.5 m

 

*

*

 

 

 

 

 

 

 

 

3-1/2 ft.

1.1 m

7 ft.

 

2.1 m

 

*

*

4-1/2 ft.

1.4 m

15 ft.

 

4.6 m

 

*

*

 

 

H Max. =15 ft. (4.6 m)

 

 

* No specific restrictions on this value

EXCEPT V1 + V2 + H1 cannot exceed 40 ft. (12.2 m)

V1

V1 Minimum

H1 + H2 Maximum

V2

V1 + V2 Min.

90 Elbow

1/2 ft.

152 mm

*

*

1/2 ft.

152 mm

1 ft.

305 mm

*

*

1-1/2 ft.

457 mm

2 ft.

610 mm

*

*

 

 

 

 

 

 

2-1/2 ft.

762 mm

4 ft.

1.2 m

*

*

 

 

 

 

 

 

3-1/2 ft.

1.1 m

6 ft.

1.8 m

*

*

4-1/2 ft.

1.4 m

14 ft.

4.3 m

*

*

H1 + H2 MAX. =14 ft. (4.6 m)

* No specific restrictions on this value EXCEPT V1 + V2 + H1 + H2 cannot exceed 40 ft. (12.2 m)

H1

V1

INSTALLED

HORIZONTALLY

Figure 7.10

30

Heatilator • GDST3831I • 2127-900 Rev. F • 10/08

Image 30
Contents Do Discardnot ModelsWhat to do if you smell gas HOT SurfacesCongratulations Homeowner Reference InformationXxxxxxxx Table of Contents User GuideElectrical Information Appliance SetupTroubleshooting FinishingCONDITIONS, Exclusions & Limitation of Liability Limited Lifetime Warranty Listing and Code Approvals Installation of Carbon Monoxide Detectors Requirements for the Commonwealth of MassachusettsGas Fireplace Safety Operating Instructions User GuideYour Fireplace Fan Kit optional Fixed Glass AssemblyRemote Controls, Wall Controls and Wall Switches Clear SpaceDo not Connect 110 VAC to the Control Valve Lighting Instructions IPIFinal inspection by What to do if YOU Smell GASFrequently Asked Questions Issue SolutionsAfter Fireplace is Lit Glass Cleaning Maintenance and ServiceMaintenance Tasks-Homeowner Remote ControlVenting Maintenance Tasks-Qualified Service TechnicianGasket Seal and Glass Assembly Inspection LogsBurner Ignition and Operation IPI Pilot Flame PatternsGetting Started Typical Appliance SystemDesign and Installation Considerations Tools and Supplies NeededInspect Appliance and Components Framing and Clearances Selecting Appliance LocationMinimum Framing Dimensions Constructing the Appliance ChaseClearances Mantel and Wall Projections TOP View Fireplace OpeningTermination Locations Vent Termination Minimum ClearancesCovered Alcove Applications Continue Adding Vent Components Install Support BracketsTo Install the Heat Shield CorrectVent Table Key Vent Information and DiagramsApproved Pipe Use of ElbowsUse of Flex Vent Vent Diagrams Top Vent Horizontal Termination One ElbowV1 Minimum H1 Maximum Top Vent Horizontal Termination Two Elbows V1 Minimum H1 + H2 MaximumTop Vent Horizontal Termination Three Elbows V1 Minimum H1 + H2 Maximum V1 + V2 MinExhaust restrictor Instructions Two Elbows Three Elbows Minimum Maximum + V 2 MinWall Penetration Framing Vent Clearances and FramingPipe Clearances to Combustibles Combustible Wall PenetrationInstall the Ceiling Firestop Pipe SLPInstall Attic Insulation Shield Flat Ceiling InstallationVaulted Ceiling Installation Appliance Preparation Securing and Leveling the ApplianceInstalling Vent Pipe Assemble Vent SectionsAssemble Slip Sections Securing the Vent SectionsInstalling Decorative Ceiling Components Disassemble Vent SectionsInstalling Metal Roof Flashing Assemble and Install Storm CollarInstall RF4-8 Apply Sealant TOP & Partial SidesInstalling Vertical Termination Cap Installing Decorative Wall ComponentsHeat Shield Requirements for Horizontal Termination Install Horizontal Termination Cap 22 Venting through the wallGas Pressure Gas InformationFuel Conversion Gas ConnectionElectrical Information Wiring RequirementsOptional Accessories Requirements Code CSA C22.1Intellifire Ignition Wiring Diagram with Remote Receiver Junction Box Installation Wall Switch Installation for Fan OptionalFinishing To install the Splatter Guard Splatter GuardTo Close the Lower Access Panel To Remove the Splatter GuardAppliance Setup Install the Log Assembly Models ST-550T-IPI. GDST3831IPilot Notch Install Trim Kits and Surrounds Air Shutter SettingAir Shutter Settings Troubleshooting Symptom Possible Cause Corrective ActionIntellifire Ignition System Remove any contaminants that may have accumulated on Appliance Dimension Diagram Electrical Access Left View Front View GAS Line Right ViewReference Materials Vent Components Diagrams SLP-TRAP1 SLP-TRAP2 AssemblySLP-DCF-BK SLK-SNKD SLP-CCS-BK SLP-TVHW DVP-2SL SLP-WT-BK SL-2DVPSLP-HRC-SS SLP-HRC-ZC-SS Horizontal Termination CAP DVP-TB1 Horizontal Termination CAPLog Set Assembly Service PartsAt Depot Service Parts ListStocked Description Comments Part NumberIntermittent Pilot Ignition Valve Assembly Contact Information