Hearth and Home Technologies TIARAI-CES, TIARA II-B, TIARAI-BR-B How to Use the Vent Graph

Page 12

D. How to Use the Vent Graph

E. Venting Guidelines

NOTE: IF YOUR INSTALLATION FALLS WITHIN A SHADED AREA ON THE GRAPH, THE DAMPER MUST BE USED.* SEE INFORMATION ON DAMPER ADJUSTMENT ON PAGE 31.

*In the Commonwealth of Massachusetts, the word damper shall be replaced with the words flue restrictor.

1. Measure the distance from the top of appliance to the center of the 90° elbow. On the graph below, draw a horizontal line from that measurement on the vertical axis across until it intersects with the slanted line.

The maximum horizontal vent run is 20 ft. (6m) when the vertical vent rise is 10 ft. (3m).

The minimum horizontal vent run is 6 in. (152mm).

Horizontal sections require a 1/4 in. (6mm) rise for every 12 in. (305 mm) of horizontal travel.

Exterior Vent Diameter = 6-5/8 in. (168mm); Inner Vent Diameter = 4 in. (102mm).

2.From the point of this intersection, draw a vertical line to

the bottom of the graph.

 

Horizontal sections require noncombustible support

3. The point at which this line meets the bottom line of the

 

every 3 ft. (914mm), e.g. wall straps.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

graph is the maximum length of the horizontal run.

• For any

vertical

termination

a minimum of 6 ft. (2m)

 

 

 

 

 

Example 1: If the vertical dimension from the center line of

 

vertical must be used.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

the flue vent to the center of the 90° elbow is 7 ft. (2m), the

 

EXCEPTIONS FOR HORIZONTAL INSTALLATIONS:

horizontal run to the outer wall flange must not exceed 16

 

*When installing the Tiara I-B or Tiara II-B in a rear vent

ft. (5m).

 

 

 

 

.

 

 

 

 

configuration with no vertical rise, a Snorkel Kit must be

Example 2: If the vertical dimension from the center line of

used. Refer to venting components.

the flue vent is 21 ft. (6m), the horizontal run to the outer wall

*The maximum horizontal vent run is 3 ft. (914mm).

flange must not exceed 12 ft. 10 in. (4m).

*The maximum horizontal vent run with a 45° elbow is 2 ft.

 

 

 

 

 

4. Each 90° elbow is equivalent to 3 ft. (914mm) of vent

(609mm).

 

 

 

 

 

 

 

 

 

 

 

 

pipe and each 45° elbow is equivalent to 1 ft. (305mm)

*The minimum horizontal vent run is 6 in. (152mm).

of vent pipe, and must be subtracted from the vent pipe

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

run. A single horizontal to vertical 90° elbow is already

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

calculated into

the

allowable

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

20 ft. (6m) run. Each additional

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

90°

elbow

reduces the

 

 

 

 

 

Part #SLK-991DA

 

 

 

 

 

 

 

 

 

 

 

maximum horizontal distance

40 ft. (12m)

40'

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

by 3 ft. (914mm).

 

MaximumVertical

39'

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

38'

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

37'

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Example:

The use of 3 elbows

 

36'

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

35'

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

34'

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

would

reduce

the

allowable

 

32'

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

horizontal run to 9 ft. (3 -1 =

 

30'

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

28'

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2 elbows x 3 ft. = 6 ft.; 20 ft.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Damper position

 

 

 

 

 

 

 

 

26'

 

 

 

 

 

 

 

 

 

 

max. - 6 ft. = 14 ft. max.).

 

 

 

 

more CLOSED in

 

 

 

 

 

 

 

 

24'

 

 

 

 

this area

 

 

 

 

 

 

 

Example 2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

22'

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

20'

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

18'

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

VERTICAL DISTANCE

16'

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FROM APPLIANCETO 90°

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

14'

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ELBOW

 

 

 

 

 

 

 

 

 

Damper position

 

 

 

 

 

 

 

 

12'

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

more OPEN in

 

 

 

 

 

 

 

 

 

10'

 

 

 

 

 

 

 

 

 

 

 

this area

 

 

 

 

 

 

 

 

Example 1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8'

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SLK-01TRD

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6'

 

 

 

 

 

NO Damper in

 

 

 

 

 

 

 

 

 

4'

 

 

 

 

 

 

this area

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2'

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6 ft. (2m) MinimumVerticalTermination

2'

 

4' 6 '

 

8' 10' 12'

14' 15' 16' 17' 18' 19' 20'

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3 ft. (914mm)MaximumHorizontalrun with no verticalpipe

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

C

 

 

 

 

 

 

 

 

 

 

 

 

and with 1/4 in. (6mm) rise per foot. Must use Snorkel cap.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

L

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CL For rear vent or top of

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

stove for top vent.

 

 

 

6 in. (152mm) Minimum starter pipe

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Figure 5.2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Page 12

Heat & Glo · Tiara I B & Tiara II B · 7010-149M

August 1, 2008

Image 12
Contents Installation and Operation What to do if you smell gasHot glass will cause burns Congratulations Location Hang tag attached to rear of applianceTable of Contents 1Listing and Code Approvals Requirements for the Commonwealth of Massachusetts Design & Installation Considerations Tools will apply to every installationGetting Started Tools and Supplies NeededAppliance Location and Clearances Selecting Appliance LocationClearances to Combustibles Tiara I-B ModelClearances to Combustibles Tiara II-B Tiara II B4Termination Locations Vent Termination Minimum ClearancesAlcove Applications Vent Information Venting ComponentsUse of Elbows Measuring StandardsHow to Use the Vent Graph Horizontal Termination Step203mm Vinyl Siding Vertical Termination Direct Vent PipeStep Twist-lock the vent cap and seal Cathedral Ceiling Level Cathedral Ceiling Support BoxClass a Metal Chimney Type C Up & Out Installation Type D Hearth Mount Type a & B Co-Axial to Co-LinearExisting Masonry Chimney Cut and bend flashing as needed to fit Sealant adhesive Flex Liner Flex Coupler Sheet Metal Screws Gas Information Fuel ConversionsConverting to LP Gas Tiara I-B Burner RemovalValve Regulator Replacement Tiara I-B and Tiara II-BTiara I-B 063 106 Tiara II-B 073 120 Gas Pressures Screws Rubber Gasket Identification Label FGas Connection Check for GAS LeaksRecommendation for Wire Connecting to the ApplianceStanding Pilot Ignition System Wiring Wire Size Max. LengthIgnition Module Access and Battery Replacement Appliance Setup Remove Shipping MaterialsTop to Rear Vent Conversion Damper Adjustment Top Vent InstallationsRear Vent Installations Shutter Adjustment Installing the Baffle Tiara I-BBrick Installation Tiara II-B Leg Leveling System19 Complete brick installation Positioning the Logs Tiara I-BAccessories Positioning the Logs Tiara II-B EmbersMineral Wool Optional Blower Wing NUTLock NUT Stem Warming Shelves Installation Glass ReplacementOperating Instructions Before Lighting ApplianceControls For Your Safety Read Before Lighting Lighting ApplianceFrequently Asked Questions Initial Break-in ProcedureAfter Appliance is Lit Troubleshooting Symptom Possible Cause Corrective ActionBe Placed in this Opening Maintaining and Servicing Appliance After servicingMaintenance Tasks Inspect Necessary. USE Caution When CLEANING/HANDLING Ceramic BurnerAppliance Dimension Diagram Tiara I-B Reference MaterialsAppliance Dimension Diagram Tiara II-B Vent Components Diagram SLP4M SLP6AM SLP24M SLP36M SLP48MVent Components List HHT SL-PTermination Caps & Kits Tiara I-B DescriptionService Parts List cont’d PBE-5 Accessories Tiara I-B Tiara II-B LPK-T2 Tiara II-B Accessories Tiara II-B Warranty Policy Limited Lifetime Warranty Heat & GLO GAS Appliance ProductsHomeowner’s Notes Tiara I B Tiara II B Contact InformationDealer Telephone

TIARAI-CTO, TIARAI-BK-B, TIARA II-B, TIARAI-BR-B, TIARAI-CES specifications

Hearth and Home Technologies offers a range of innovative gas and wood fireplace products, including the TIARA I-B, TIARA I-CTO, TIARA I-CES, TIARA II-B, and TIARA I-BR-B models. Each of these fireplaces combines aesthetic appeal with high functionality, creating a comfortable and stylish heating solution for any space.

The TIARA I-B is a versatile gas fireplace that features a contemporary design, perfect for modern homes. It comes with a large viewing area that showcases the beautiful flames while providing efficient heating. The model is equipped with advanced gas burner technology, ensuring a steady and even flame pattern, which enhances both the ambiance and warmth of the room.

The TIARA I-CTO boasts an innovative convection technology option, which allows for even heat distribution throughout the space. This model includes an easy-to-use remote control that enables users to adjust the flame height and heat output from across the room, providing an unparalleled level of convenience. Its sleek design can seamlessly blend into various interiors, making it a stylish choice for homeowners.

For those looking for a more efficient heating solution, the TIARA I-CES model incorporates a ceramic glass panel that enhances the fireplace's efficiency while maintaining an attractive aesthetic. The improved thermal performance allows for reduced fuel consumption and lower heating costs without compromising on warmth or style.

The TIARA II-B enhances the collection with its distinctive design and expanded features. This model comes with various decorative options, including multiple log set styles and media kits, allowing homeowners to customize their fireplace to match their unique taste. Its durable construction ensures longevity and reliability while providing warmth in colder months.

Finally, the TIARA I-BR-B is designed with a traditional aesthetic but incorporates modern technology. It delivers exceptional efficiency with the use of high-quality materials and advanced combustion technology. This fireplace not only provides a classic look but also meets modern energy efficiency standards, making it an eco-friendly choice for responsible heating.

In summary, the TIARA series from Hearth and Home Technologies combines beauty, technology, and efficiency. Each model is designed to suit different preferences and needs, ensuring that homeowners find the perfect fireplace solution. Whether you are after modern design or classic charm, the TIARA fireplaces deliver warmth and style in equal measure.