Hearth and Home Technologies TIARA II-B, TIARAI-CES, TIARAI-BR-B Horizontal Termination, Step

Page 13

F. Horizontal Termination

Type A - Up & Out Installation

90° ELBOW

CENTER LINE

TERMINATION CAP

PIPE LENGTH

WALL THIMBLE/

HEAT SHIELD

WALL THIMBLE COVER

PIPE LENGTH

Type B - Straight Out Installation

SNORKEL KIT

15-5/8 in. (397mm)

WALL THIMBLE COVER

21 in.

(533mm)

CENTER

LINE

PIPE LENGTH

WALL THIMBLE / HEAT SHIELD

WALL STRAP 14 in. (356mm) Wide

Type C - 45° Elbow in Corner Installation

 

Wall Thimble/Heat Shield

45° Elbow

3/8 in. (10mm)

 

 

Clearance from

 

stove corner to

 

combustible wall

 

(for valve access

 

on side).

3/8 in. (10mm) Clearance from stove corner to combustible wall.

Figure 5.3

Step 1.

Determine the desired location of the appliance. Check to ensure that wall studs or roof rafters are not in the way when the venting system is being planned. If this is the case, you may want to adjust the location of the appliance.

WARNING

Fire Hazard.

Exhaust Fume Risk.

Impaired Performance of Appliance.

Ensure vent components are locked together correctly.

Pipe may separate if not properly joined.

Step 2.

Direct vent pipe is designed with a locking connection. To connect the venting system to the appliance flue outlet, a twist-lock adapter is built into the appliance at the factory. Wall thickness may vary. Remember to include wall thickness in minimum clearances when figuring venting lengths for your installation needs.

Note: Female ends of direct vent pipe/elbows are designed to slide straight onto the male ends of adjacent pipes by orienting the pipe indentations so they match and slide into the entry slots on the male ends, see Figure 5.4. Push the pipe sections completely together, then twist-lock one section clockwise approximately one-quarter turn, until the two sections are fully locked. The female locking lugs may not be visible from the outside. They may be located by examining the inside of the female ends.

Female Locking Lugs

Male Locking Lugs

Figure 5.4

WARNING

Fire Risk. Explosion Risk. Combustion Fume Risk.

Use vent run supports per installation instructions. Connect vent sections per installation instructions.

Maintain all clearances to combustibles.

Do NOT allow vent to sag below connection point to appliance.

Maintain specified slope (if required).

Improper support may allow vent to sag or separate.

August 1, 2008

Heat & Glo · Tiara I B & Tiara II B · 7010-149M

Page 13

Image 13
Contents What to do if you smell gas Installation and OperationHot glass will cause burns Location Hang tag attached to rear of appliance CongratulationsTable of Contents 1Listing and Code Approvals Requirements for the Commonwealth of Massachusetts Tools will apply to every installation Design & Installation ConsiderationsGetting Started Tools and Supplies NeededSelecting Appliance Location Appliance Location and ClearancesClearances to Combustibles Tiara I-B ModelTiara II B Clearances to Combustibles Tiara II-BVent Termination Minimum Clearances 4Termination LocationsAlcove Applications Venting Components Vent InformationUse of Elbows Measuring StandardsHow to Use the Vent Graph Step Horizontal Termination203mm Vinyl Siding Direct Vent Pipe Vertical TerminationStep Twist-lock the vent cap and seal Level Cathedral Ceiling Support Box Cathedral CeilingClass a Metal Chimney Type a & B Co-Axial to Co-Linear Type C Up & Out Installation Type D Hearth MountExisting Masonry Chimney Cut and bend flashing as needed to fit Sealant adhesive Flex Liner Flex Coupler Sheet Metal Screws Fuel Conversions Gas InformationConverting to LP Gas Tiara I-B Burner RemovalTiara I-B and Tiara II-B Valve Regulator ReplacementTiara I-B 063 106 Tiara II-B 073 120 Screws Rubber Gasket Identification Label F Gas PressuresCheck for GAS Leaks Gas ConnectionConnecting to the Appliance Recommendation for WireStanding Pilot Ignition System Wiring Wire Size Max. LengthIgnition Module Access and Battery Replacement Remove Shipping Materials Appliance SetupTop to Rear Vent Conversion Top Vent Installations Damper AdjustmentRear Vent Installations Installing the Baffle Tiara I-B Shutter AdjustmentBrick Installation Tiara II-B Leg Leveling SystemPositioning the Logs Tiara I-B 19 Complete brick installationPositioning the Logs Tiara II-B Embers AccessoriesMineral Wool Wing NUT Optional BlowerLock NUT Stem Glass Replacement Warming Shelves InstallationBefore Lighting Appliance Operating InstructionsControls Lighting Appliance For Your Safety Read Before LightingInitial Break-in Procedure Frequently Asked QuestionsAfter Appliance is Lit Symptom Possible Cause Corrective Action TroubleshootingBe Placed in this Opening After servicing Maintaining and Servicing ApplianceNecessary. USE Caution When CLEANING/HANDLING Ceramic Burner Maintenance Tasks InspectReference Materials Appliance Dimension Diagram Tiara I-BAppliance Dimension Diagram Tiara II-B SLP4M SLP6AM SLP24M SLP36M SLP48M Vent Components DiagramHHT SL-P Vent Components ListTermination Caps & Kits Description Tiara I-BService Parts List cont’d PBE-5 Accessories Tiara I-B Tiara II-B LPK-T2 Tiara II-B Accessories Tiara II-B Limited Lifetime Warranty Heat & GLO GAS Appliance Products Warranty PolicyHomeowner’s Notes Contact Information Tiara I B Tiara II BDealer Telephone

TIARAI-CTO, TIARAI-BK-B, TIARA II-B, TIARAI-BR-B, TIARAI-CES specifications

Hearth and Home Technologies offers a range of innovative gas and wood fireplace products, including the TIARA I-B, TIARA I-CTO, TIARA I-CES, TIARA II-B, and TIARA I-BR-B models. Each of these fireplaces combines aesthetic appeal with high functionality, creating a comfortable and stylish heating solution for any space.

The TIARA I-B is a versatile gas fireplace that features a contemporary design, perfect for modern homes. It comes with a large viewing area that showcases the beautiful flames while providing efficient heating. The model is equipped with advanced gas burner technology, ensuring a steady and even flame pattern, which enhances both the ambiance and warmth of the room.

The TIARA I-CTO boasts an innovative convection technology option, which allows for even heat distribution throughout the space. This model includes an easy-to-use remote control that enables users to adjust the flame height and heat output from across the room, providing an unparalleled level of convenience. Its sleek design can seamlessly blend into various interiors, making it a stylish choice for homeowners.

For those looking for a more efficient heating solution, the TIARA I-CES model incorporates a ceramic glass panel that enhances the fireplace's efficiency while maintaining an attractive aesthetic. The improved thermal performance allows for reduced fuel consumption and lower heating costs without compromising on warmth or style.

The TIARA II-B enhances the collection with its distinctive design and expanded features. This model comes with various decorative options, including multiple log set styles and media kits, allowing homeowners to customize their fireplace to match their unique taste. Its durable construction ensures longevity and reliability while providing warmth in colder months.

Finally, the TIARA I-BR-B is designed with a traditional aesthetic but incorporates modern technology. It delivers exceptional efficiency with the use of high-quality materials and advanced combustion technology. This fireplace not only provides a classic look but also meets modern energy efficiency standards, making it an eco-friendly choice for responsible heating.

In summary, the TIARA series from Hearth and Home Technologies combines beauty, technology, and efficiency. Each model is designed to suit different preferences and needs, ensuring that homeowners find the perfect fireplace solution. Whether you are after modern design or classic charm, the TIARA fireplaces deliver warmth and style in equal measure.