Hearth and Home Technologies TIARA II-B Appliance Location and Clearances, Model, Tiara I B

Page 7

3

Appliance Location and Clearances

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NOTE:

 

WARNING

 

· Illustrations reflect typical installations and are FOR

 

 

 

Fire Risk

DESIGN PURPOSES ONLY.

· Illustrations/diagrams are not drawn to scale.

Provide adequate clearance:

Around air openings

· Actual installation may vary due to individual design

To combustibles

preference.

For service access

Locate appliance away from traffic areas.

A. Selecting Appliance Location

When selecting a location for your appliance it is important to consider the required clearances to wall (see Figure 3.1).

NOTE: For actual appliance dimensions refer to Section 12.

B. Clearances to Combustibles - Tiara I-B

WARNING

Fire Risk.

Locate and install appliance to all clearance specifications in manual.

 

 

F

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

C

 

 

 

 

B

 

 

 

 

 

 

 

 

 

 

A

 

 

A

E

 

C

 

 

 

 

 

 

 

 

 

 

 

 

 

 

"A" measurement is from

 

 

 

 

 

 

 

 

appliance top, not side

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

G

 

H

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

G

 

 

 

 

 

 

 

 

 

 

A

 

 

A

 

 

 

 

 

 

 

 

 

 

 

 

 

D

 

 

 

 

 

 

 

 

 

 

 

90˚ off top up and out ceiling

 

 

 

 

 

 

 

 

 

 

 

 

H

 

Model

A

B

C

D

E

F

G

Top of

Side of

Inside

pipe

pipe

Outside

 

 

 

 

 

 

 

 

 

 

 

corner

 

 

 

 

 

 

 

 

 

 

 

wall vent

Tiara I B

Inches

8-1/2

1/4

3/8

54

36

40

27

1-1/2

1

9

 

 

Millimeters

216

6

9.5

1372

914

1016

686

38

25

229

Figure 3.1

 

 

 

 

 

 

 

 

 

 

 

August 1, 2008

 

 

Heat & Glo · Tiara I B & Tiara II B · 7010-149M

 

 

 

Page 7

Image 7
Contents What to do if you smell gas Installation and OperationHot glass will cause burns Location Hang tag attached to rear of appliance CongratulationsTable of Contents 1Listing and Code Approvals Requirements for the Commonwealth of Massachusetts Tools and Supplies Needed Design & Installation ConsiderationsTools will apply to every installation Getting StartedModel Appliance Location and ClearancesSelecting Appliance Location Clearances to Combustibles Tiara I-BTiara II B Clearances to Combustibles Tiara II-BVent Termination Minimum Clearances 4Termination LocationsAlcove Applications Measuring Standards Vent InformationVenting Components Use of ElbowsHow to Use the Vent Graph Step Horizontal Termination203mm Vinyl Siding Direct Vent Pipe Vertical TerminationStep Twist-lock the vent cap and seal Level Cathedral Ceiling Support Box Cathedral CeilingClass a Metal Chimney Type a & B Co-Axial to Co-Linear Type C Up & Out Installation Type D Hearth MountExisting Masonry Chimney Cut and bend flashing as needed to fit Sealant adhesive Flex Liner Flex Coupler Sheet Metal Screws Tiara I-B Burner Removal Gas InformationFuel Conversions Converting to LP GasTiara I-B and Tiara II-B Valve Regulator ReplacementTiara I-B 063 106 Tiara II-B 073 120 Screws Rubber Gasket Identification Label F Gas PressuresCheck for GAS Leaks Gas ConnectionWire Size Max. Length Recommendation for WireConnecting to the Appliance Standing Pilot Ignition System WiringIgnition Module Access and Battery Replacement Remove Shipping Materials Appliance SetupTop to Rear Vent Conversion Top Vent Installations Damper AdjustmentRear Vent Installations Leg Leveling System Shutter AdjustmentInstalling the Baffle Tiara I-B Brick Installation Tiara II-BPositioning the Logs Tiara I-B 19 Complete brick installationPositioning the Logs Tiara II-B Embers AccessoriesMineral Wool Wing NUT Optional BlowerLock NUT Stem Glass Replacement Warming Shelves InstallationBefore Lighting Appliance Operating InstructionsControls Lighting Appliance For Your Safety Read Before LightingInitial Break-in Procedure Frequently Asked QuestionsAfter Appliance is Lit Symptom Possible Cause Corrective Action TroubleshootingBe Placed in this Opening After servicing Maintaining and Servicing ApplianceNecessary. USE Caution When CLEANING/HANDLING Ceramic Burner Maintenance Tasks InspectReference Materials Appliance Dimension Diagram Tiara I-BAppliance Dimension Diagram Tiara II-B SLP4M SLP6AM SLP24M SLP36M SLP48M Vent Components DiagramHHT SL-P Vent Components ListTermination Caps & Kits Description Tiara I-BService Parts List cont’d PBE-5 Accessories Tiara I-B Tiara II-B LPK-T2 Tiara II-B Accessories Tiara II-B Limited Lifetime Warranty Heat & GLO GAS Appliance Products Warranty PolicyHomeowner’s Notes Contact Information Tiara I B Tiara II BDealer Telephone

TIARAI-CTO, TIARAI-BK-B, TIARA II-B, TIARAI-BR-B, TIARAI-CES specifications

Hearth and Home Technologies offers a range of innovative gas and wood fireplace products, including the TIARA I-B, TIARA I-CTO, TIARA I-CES, TIARA II-B, and TIARA I-BR-B models. Each of these fireplaces combines aesthetic appeal with high functionality, creating a comfortable and stylish heating solution for any space.

The TIARA I-B is a versatile gas fireplace that features a contemporary design, perfect for modern homes. It comes with a large viewing area that showcases the beautiful flames while providing efficient heating. The model is equipped with advanced gas burner technology, ensuring a steady and even flame pattern, which enhances both the ambiance and warmth of the room.

The TIARA I-CTO boasts an innovative convection technology option, which allows for even heat distribution throughout the space. This model includes an easy-to-use remote control that enables users to adjust the flame height and heat output from across the room, providing an unparalleled level of convenience. Its sleek design can seamlessly blend into various interiors, making it a stylish choice for homeowners.

For those looking for a more efficient heating solution, the TIARA I-CES model incorporates a ceramic glass panel that enhances the fireplace's efficiency while maintaining an attractive aesthetic. The improved thermal performance allows for reduced fuel consumption and lower heating costs without compromising on warmth or style.

The TIARA II-B enhances the collection with its distinctive design and expanded features. This model comes with various decorative options, including multiple log set styles and media kits, allowing homeowners to customize their fireplace to match their unique taste. Its durable construction ensures longevity and reliability while providing warmth in colder months.

Finally, the TIARA I-BR-B is designed with a traditional aesthetic but incorporates modern technology. It delivers exceptional efficiency with the use of high-quality materials and advanced combustion technology. This fireplace not only provides a classic look but also meets modern energy efficiency standards, making it an eco-friendly choice for responsible heating.

In summary, the TIARA series from Hearth and Home Technologies combines beauty, technology, and efficiency. Each model is designed to suit different preferences and needs, ensuring that homeowners find the perfect fireplace solution. Whether you are after modern design or classic charm, the TIARA fireplaces deliver warmth and style in equal measure.