Hearth and Home Technologies Soho24B owner manual Install RF4-8, Apply Sealant TOP & Partial Sides

Page 25

H. Install RF4-8

The RF4-8 may be used in place of the roof flashing and storm collar (Sections 8.F. and 8.G.)

Pipe must be supported within 12 inches of the roofline us- ing plumbers strapping or an SLP-FS when using the RF4- 8 Flashing. Refer to Section 8.C Securing Vent Sections.

SECURE WITH 4

SCREWS NO LONGER

THAN 1 IN. (25 MM)

SLP-FS

Figure 8.15 Secure Pipe with SLP-FS

Trim the rubber boot (using scissors or a utility knife), cutting along the marked measurement lines. See Figure 8.16. Use the 150 mm line.

Lubricate pipe or flue with water and slide the flashing down. It may be necessary to trim the top shingles around the base of the rubber boot to ensure a good fit.

Draw around flashing, remove.

Apply silicone sealant to roof inside the lines (Figure 8.17)

Lubricate pipe or flue with water and slide flashing down. Seat firmly in sealant. Nail roof flashing to the roof.

Apply silicone sealant on the top outside of the base plate on the sides and on top edge. See Figure 8.18. Install shingles, Apply sealant at the top edge of the rubber boot. See Figure 8.19.

We recommend that you top coat with conventional acrylic house paint to improve the appearance of your galvanized base flashing.

Figure 8.16 Trim Rubber Boot

Figure 8.17 Apply Sealant

APPLY SEALANT

TOP & PARTIAL SIDES

Figure 8.18 Slide Flashing Down, Secure & Apply Sealant

SILICONE SEALANT (TOP OF BOOT)

SHINGLES TRIMMED

FLASHING OVER

SHINGLES OVER

SHINGLES

FLASHING

 

Figure 8.19 Installation Complete

Heat & Glo • Soho24B • 2137-900 Rev. H • 10/08

25

 

Image 25
Contents What to do if you smell gas Model Soho24BHot glass will cause burns Homeowner Reference Information CongratulationsTable of Contents Listing and Code Approvals Requirements for the Commonwealth of Massachusetts Installation of Carbon Monoxide DetectorsGetting Started Installation to ensure maximum safety and benefitTools and Supplies Needed Selecting Appliance Location Framing and ClearancesMantel Projections Clearances Constructing the Appliance ChaseVent Termination Minimum Clearances Termination LocationsSee .4 for specific clearances Alcove Applications Vent Table Key Vent Information and DiagramsUse of Elbows Measuring StandardsTop Vent Horizontal Termination One Elbow Vent DiagramsTwo Elbows Minimum MaximumV1 Min H1 Max V2 Min H2 Max Top Vent Horizontal Termination Three ElbowsV1 = 45 ft Max .72 m V1 = 3 ft Min mm Top Vent Vertical Termination No ElbowV1 Minimum H1 Maximum V1 + V1 Minimum H1+ H2 Maximum V1+ V2 Minimum Top Vent Vertical Termination Three ElbowsPipe Clearances to Combustibles Vent Clearances and FramingWall Penetration Framing Combustible Wall PenetrationPipe SLP Vertical Penetration FramingFlat Ceiling Installation Install Attic Insulation ShieldVaulted Ceiling Installation Top Vent Appliance PreparationProper Positioning, Leveling Securing and Leveling the ApplianceAssemble Vent Sections Installing Vent PipeSecure the Vent Sections Assemble Slip SectionsDisassemble Vent Sections Install Decorative Ceiling ComponentsAssemble and Install Storm Collar Install Metal Roof FlashingApply Sealant TOP & Partial Sides Install RF4-8Install Decorative Wall Components Install Vertical Termination CapHeat Shield Requirements for Horizontal Termination 22 Venting through the wall Install Horizontal Termination CapFuel Conversions Gas Connection Gas InformationGas Pressures Pressure Natural Gas PropaneHigh Altitude Installations Electrical Information Recommendation for WireGRN wire Ground attached To GRN screw with Inside box Junction Box InstallationFacing Material FinishingSee for combustible/non-combustible definitions Clean the Appliance Appliance SetupAccessories Remove Shipping MaterialsPositioning Stones Stone Placement Soho24BNo Stones in this Area Air Shutter Setting Glass AssemblyRemoving Glass Assembly Replacing Glass AssemblyBefore Lighting Appliance Operating InstructionsLighting Instructions IPI Turn off all electric power to the applianceFinal inspection by Initial Break-in Procedure Frequently Asked QuestionsAfter Appliance is Lit Intellifire Ignition System TroubleshootingSympton Possible Cause Corrective Action Symptom Possible Cause Corrective Action Maintaining and Servicing Appliance Maintenance TasksRecommend addition of screen if one is not present Inspect Maintenance TasksAppliance Dimensions Table Appliance Dimension DiagramReference Materials Location Inches MillimeterSL Series Components Vent Components DiagramsRF4-8 ElbowRoof Flashing Ceiling Firestop Support Effective Height/LengthSupport Box-Black SnorkelAdapter Ceiling Firestop BlackPart number list on following Service PartsAt Depot StockedNo longer available IPI Valve Assembly CONDITIONS, Exclusions & Limitation of Liability Limited Lifetime Warranty Contact Information

Soho24B specifications

Hearth and Home Technologies has once again pushed the boundaries of home heating with the introduction of the Soho24B. This innovative gas fireplace is designed to provide warmth and comfort, while also serving as a striking centerpiece for any living space. A blend of modern aesthetics and advanced technology, the Soho24B delivers a variety of features that elevate the standard of home fireplaces.

One of the standout features of the Soho24B is its sleek and minimalist design, which allows it to seamlessly integrate into contemporary living environments. With a focus on clean lines and an elegant finish, it offers an unobtrusive yet sophisticated look. The large glass viewing area ensures that the dancing flames are always visible, creating a cozy ambiance that enhances any room.

Equipped with advanced burner technology, the Soho24B produces realistic flame patterns that can be customized to suit personal preferences. Users can adjust the flame height and intensity using an intuitive remote control, allowing for both mood lighting and powerful heat output. The versatility of the fireplace makes it suitable for various settings, from intimate family gatherings to lively social events.

Safety is paramount, and the Soho24B is designed with multiple features to ensure worry-free operation. The unit includes an automatic shut-off mechanism that activates when the appliance is not properly ventilated or if it overheats. Additionally, the unit’s glass surface remains cool to the touch when in operation, providing peace of mind for families with young children or pets.

Efficiency is another key characteristic of the Soho24B. Engineered with energy-efficient technology, it ensures maximum heat output with minimal fuel consumption. The fireplace adheres to strict environmental regulations, making it an eco-friendly option for homeowners looking to reduce their carbon footprint without sacrificing comfort.

Moreover, the Soho24B can be installed in both vented and vent-free configurations, offering flexibility to homeowners regarding their heating needs and architectural constraints. This adaptability, combined with the unit’s powerful heating capabilities, makes it an excellent choice for any room in the house.

In summary, the Hearth and Home Technologies Soho24B stands out as a perfect fusion of style, technology, and efficiency. Its stunning design, user-friendly features, and commitment to safety make it a compelling option for those seeking a reliable and beautiful heating solution for their home. Whether you are cozying up on a chilly evening or entertaining friends, the Soho24B creates a warm and inviting atmosphere that is hard to beat.