Hearth and Home Technologies Soho24B owner manual Symptom Possible Cause Corrective Action

Page 41

Intellifire Ignition System - (continued)

Symptom

Possible Cause

Corrective Action

 

 

 

3. Continued

d. Damaged pilot as-

Verify that ceramic insulator around the sensor rod is not cracked, damaged, or

 

sembly or dirty sensor

loose. Verify connection from sensor rod to white sensor wire. Clean sensor rod with

 

rod.

emery cloth to remove any contaminants that may have accumulated on sensor rod.

 

 

Verify continuity with a multimeter with ohms set at lowest range.

 

e. Faulty module.

Turn ON/OFF rocker switch or wall switch to OFF position. Remove ignitor wire

 

 

“I” from module. Place ON/OFF Rocker switch or wall switch in ON position. Hold

 

 

ground wire about 3/16 inch away from “I” terminal on module. If there is no spark

 

 

at “I” terminal module must be replaced. If there is a spark at “I” terminal, module

 

 

is fine. Inspect pilot assembly for shorted sparker wire or cracked insulator around

 

 

electrode.

4. Pilot sparks, but

a. Correct gas supply.

Verify that incoming gas line ball valve is “open”. Verify that inlet pressure reading is

Pilot will not light.

 

within acceptable limits, inlet pressure must not exceed 14 in. W.C.

 

b. Ignitor gap is too

Verify that spark gap from ignitor to pilot hood is .17 in. or 1/8 in.

 

large.

 

 

c. Module is not

Verify module is securely grounded to metal chassis of appliance.

 

grounded.

 

Heat & Glo • Soho24B • 2137-900 Rev. H • 10/08

41

 

Image 41
Contents Hot glass will cause burns Model Soho24BWhat to do if you smell gas Homeowner Reference Information CongratulationsTable of Contents Listing and Code Approvals Requirements for the Commonwealth of Massachusetts Installation of Carbon Monoxide DetectorsTools and Supplies Needed Installation to ensure maximum safety and benefitGetting Started Mantel Projections Framing and ClearancesSelecting Appliance Location Clearances Constructing the Appliance ChaseSee .4 for specific clearances Termination LocationsVent Termination Minimum Clearances Alcove Applications Vent Table Key Vent Information and DiagramsUse of Elbows Measuring StandardsTop Vent Horizontal Termination One Elbow Vent DiagramsTwo Elbows Minimum MaximumV1 Min H1 Max V2 Min H2 Max Top Vent Horizontal Termination Three ElbowsV1 Minimum H1 Maximum V1 + Top Vent Vertical Termination No ElbowV1 = 45 ft Max .72 m V1 = 3 ft Min mm V1 Minimum H1+ H2 Maximum V1+ V2 Minimum Top Vent Vertical Termination Three ElbowsPipe Clearances to Combustibles Vent Clearances and FramingWall Penetration Framing Combustible Wall PenetrationPipe SLP Vertical Penetration FramingVaulted Ceiling Installation Install Attic Insulation ShieldFlat Ceiling Installation Top Vent Appliance PreparationProper Positioning, Leveling Securing and Leveling the ApplianceAssemble Vent Sections Installing Vent PipeSecure the Vent Sections Assemble Slip SectionsDisassemble Vent Sections Install Decorative Ceiling ComponentsAssemble and Install Storm Collar Install Metal Roof FlashingApply Sealant TOP & Partial Sides Install RF4-8Heat Shield Requirements for Horizontal Termination Install Vertical Termination CapInstall Decorative Wall Components 22 Venting through the wall Install Horizontal Termination CapFuel Conversions Gas Connection Gas InformationGas Pressures Pressure Natural Gas PropaneHigh Altitude Installations Electrical Information Recommendation for WireGRN wire Ground attached To GRN screw with Inside box Junction Box InstallationSee for combustible/non-combustible definitions FinishingFacing Material Clean the Appliance Appliance SetupAccessories Remove Shipping MaterialsPositioning Stones Stone Placement Soho24BNo Stones in this Area Air Shutter Setting Glass AssemblyRemoving Glass Assembly Replacing Glass AssemblyBefore Lighting Appliance Operating InstructionsFinal inspection by Turn off all electric power to the applianceLighting Instructions IPI After Appliance is Lit Frequently Asked QuestionsInitial Break-in Procedure Sympton Possible Cause Corrective Action TroubleshootingIntellifire Ignition System Symptom Possible Cause Corrective Action Maintaining and Servicing Appliance Maintenance TasksRecommend addition of screen if one is not present Inspect Maintenance TasksAppliance Dimensions Table Appliance Dimension DiagramReference Materials Location Inches MillimeterSL Series Components Vent Components DiagramsRF4-8 ElbowRoof Flashing Ceiling Firestop Support Effective Height/LengthSupport Box-Black SnorkelAdapter Ceiling Firestop BlackPart number list on following Service PartsNo longer available StockedAt Depot IPI Valve Assembly CONDITIONS, Exclusions & Limitation of Liability Limited Lifetime Warranty Contact Information

Soho24B specifications

Hearth and Home Technologies has once again pushed the boundaries of home heating with the introduction of the Soho24B. This innovative gas fireplace is designed to provide warmth and comfort, while also serving as a striking centerpiece for any living space. A blend of modern aesthetics and advanced technology, the Soho24B delivers a variety of features that elevate the standard of home fireplaces.

One of the standout features of the Soho24B is its sleek and minimalist design, which allows it to seamlessly integrate into contemporary living environments. With a focus on clean lines and an elegant finish, it offers an unobtrusive yet sophisticated look. The large glass viewing area ensures that the dancing flames are always visible, creating a cozy ambiance that enhances any room.

Equipped with advanced burner technology, the Soho24B produces realistic flame patterns that can be customized to suit personal preferences. Users can adjust the flame height and intensity using an intuitive remote control, allowing for both mood lighting and powerful heat output. The versatility of the fireplace makes it suitable for various settings, from intimate family gatherings to lively social events.

Safety is paramount, and the Soho24B is designed with multiple features to ensure worry-free operation. The unit includes an automatic shut-off mechanism that activates when the appliance is not properly ventilated or if it overheats. Additionally, the unit’s glass surface remains cool to the touch when in operation, providing peace of mind for families with young children or pets.

Efficiency is another key characteristic of the Soho24B. Engineered with energy-efficient technology, it ensures maximum heat output with minimal fuel consumption. The fireplace adheres to strict environmental regulations, making it an eco-friendly option for homeowners looking to reduce their carbon footprint without sacrificing comfort.

Moreover, the Soho24B can be installed in both vented and vent-free configurations, offering flexibility to homeowners regarding their heating needs and architectural constraints. This adaptability, combined with the unit’s powerful heating capabilities, makes it an excellent choice for any room in the house.

In summary, the Hearth and Home Technologies Soho24B stands out as a perfect fusion of style, technology, and efficiency. Its stunning design, user-friendly features, and commitment to safety make it a compelling option for those seeking a reliable and beautiful heating solution for their home. Whether you are cozying up on a chilly evening or entertaining friends, the Soho24B creates a warm and inviting atmosphere that is hard to beat.