D. After Appliance is Lit

Initial Break-in Procedure

When you light the appliance, you may notice that it pro- duces heat which does have an associated odor or smell. If you feel this odor is excessive it may require the initial three to four hour continuous burn on high followed by a second burn up to 12 hours to fully drive off any odor from paint and lubricants used in the manufacturing process. Condensation of the glass is normal.

NOTE: The appliance should be run three to four hours on the initial start-up. Turn it off and let it cool completely. Remove and clean the glass. Replace the glass and run the appliance for an additional 12 hours. This will help to cure the products used in the paint and logs.

During this break-in period it is recommended that some windows in the house be opened for air circulation. This will help avoid setting off smoke detectors, and help eliminate any odors associated with the appliance’s initial burning.

CAUTION

Prevent accidental appliance operation when not attended.

Unplug or remove batteries from remote control if absent or if appliance will not be used for an extended period of time.

Property damage possible from elevated temperatures.

CAUTION

Smoke and odors released during initial operation.

Open windows for air circulation.

Leave room during initial operation.

Smoke may set off smoke detectors.

Smoke and odors may be irritating to sensitive individuals.

WARNING

Fire Risk.

High Temperatures.

Keep combustible household items away from appliance. Do NOT obstruct combustion and ventilation air.

Do NOT place combustible items on top of or in front of appliance.

Keep furniture, draperies away from appliance.

WARNING

Fire Hazard.

Keep combustible materials, gasoline and other flammable vapors and liquids clear of appliance.

Do NOT store flammable materials in the appliance’s vicinity.

Do NOT use gasoline, lantern fuel, kerosene, charcoal lighter fluid or similar liquids in this appliance.

Combustible materials may ignite.

E. Frequently Asked Questions

ISSUE

SOLUTIONS

 

 

Condensation on the glass

This is a result of gas combustion and temperature variations. As the appliance

warms, this condensation will disappear.

 

 

 

Blue flames

This is a result of normal operation and the flames will begin to yellow as the appli-

ance is allowed to burn for 20 to 40 minutes.

 

 

 

 

When first operated, this appliance may release an odor for the first several hours.

Odor from appliance

This is caused by the curing of the paint and the burning off of any oils remaining

from manufacturing. Odor may also be released from finishing materials and adhe-

 

 

sives used around the appliance.

 

 

 

This is a normal result of the curing process of the paint and logs. Glass should be

Film on the glass

cleaned within 3 to 4 hours of initial burning to remove deposits left by oils from the

manufacturing process. A non-abrasive cleaner such as gas fireplace glass cleaner

 

 

may be necessary. See your dealer.

 

 

 

Noise is caused by metal expanding and contracting as it heats up and cools down,

Metallic noise

similar to the sound produced by a furnace or heating duct. This noise does not af-

 

fect the operation or longevity of the appliance.

 

 

Is it normal to see the pilot flame

In an Intellifire ignition system it is normal to see the pilot flame, but it should turn off

burn continually?

when ON/OFF is turned off. In a standing pilot system the pilot will always stay on.

 

 

34

Heat & Glo • SL-550 / 750 / 950TV-D2053-985 Rev. H • 9/06

Image 34
Contents What to do if you smell gas Congratulations Homeowner Reference InformationTable of Contents BTU Specifications 1Listing and Code ApprovalsGlass Specifications ModelsNon-Combustible Materials Specification High Altitude InstallationsCombustible Materials Specification Design and Installation Considerations Getting StartedNegative Pressure Tools and Supplies Needed Inspect Appliance and ComponentsFraming and Clearances Selecting Appliance LocationConstructing the Appliance Chase ClearancesMantel Projections Clearances to Mantels or other Combustibles above ApplianceTermination Locations Vent Termination Minimum ClearancesVent Guidelines Vent Information and DiagramsVent System Configuration Minimum Vertical Feet Pipe Clearances to Combustibles Vent Clearances and FramingVertical Penetration Framing Appliance Preparation Installing Outside Air Kit Damper AssemblyGas and Electrical Connections Securing and Leveling Appliance Proper Positioning, Leveling and Securing of aSecuring Vent Sections Installing Vent PipeAssembly of Vent Sections Attaching Vent to FireboxGas Pressures Gas InformationFuel Conversions Gas Connection Pressure Natural Gas PropaneHigh Altitude Installations Intellifire Ignition System Wiring Recommendation for WireConnecting to the Appliance Optional Accessories RequirementsStanding Pilot Ignition System Wiring Ground toJunction Box Installation Wall Switch Installation for Fan OptionalFinishing Facing MaterialAccessories Appliance SetupClean the Appliance Remove Shipping MaterialsLog Set Assembly LOGS-SL550-D Models SL-550TV-D Positioning the LogsTAB Locator Log Set Assembly LOGS-SL750-D Models SL-750TV-D, SL-950TV-D Notches Raised Flat Spots Screen Mesh Glass AssemblyShutter Settings Grilles and Trim Check Appliance Draft Operating Instructions Before Lighting Appliance Before operating this appliance have a qualified technicianLighting Appliance Intellifire IgnitionFor Your Safety Read Before Lighting Instructions Standing Pilot IgnitionInitial Break-in Procedure Frequently Asked QuestionsAfter Appliance is Lit Symptom Possible Causes Corrective Actions TroubleshootingStanding Pilot Ignition System Troubleshooting Symptom Possible Cause Corrective ActionIntellifire Ignition System Symptom Possible Causes Corrective Actions Maintaining and Servicing Appliance Before servicingInspect Maintenance Tasks Appliance Dimensions Table Appliance Dimension DiagramReference Materials Service Parts Log Set AssemblyService Parts List Additional service part numbers may appear on the followingSL-750TV-D SL-750TV-D SL-950TV-D 151SL-950TV-D SL-550 / 750 / 950TV-D-IPI Common Parts Serial # Part Number SL-550 / 750 / 950TV-D 10-06 530-510A Limited Lifetime Warranty Limited Lifetime Warranty Heat & GLO GAS Appliance ProductsContact Information Do not Discard this Manual