A. Fuel Conversions

C. Gas Connection

Before making gas connections ensure that appliance be- ing installed is compatible with the available gas type.

Any natural or propane gas conversions necessary to meet the appliance and locality needs must be made by a qualified technician using Hearth & Home Technologies specified and approved parts.

NOTE: Have the gas supply line installed in accordance with local building codes, if any. If not, follow ANSI

223.1.Installation should be done by a qualified installer approved and/or licensed as required by the locality. (In the Commonwealth of Massachusetts installation must be performed by a licensed plumber or gas fitter.)

B. Gas Pressures

Proper input pressures are required for optimum appliance performance. Gas line sizing requirements need to be made following NFPA51.

WARNING

Fire Risk. Explosion Hazard.

High pressure will damage valve.

• Disconnect gas supply piping BEFORE pressure testing gas line at test pressures above 1/2 psig.

Close the manual shutoff valve BEFORE pressure testing gas line at test pressures equal to or less than 1/2 psig.

WARNING

Verify inlet pressures.

• High pressure may cause overfire condition.

• Low pressure may cause explosion.

Verify minimum pressures when other household gas appliances are operating.

Install regulator upstream of valve if line pressure is greater than 1/2 psig.

NOTE: A listed (and Commonwealth of Massachusetts approved) 1/2 inch (13 mm) T-handle manual shut-off valve and flexible gas connector are connected to the 1/2 inch (13 mm) control valve inlet.

If substituting for these components, please consult local codes for compliance.

Refer to Reference Section 16 for location of gas line access in appliance.

NOTE: Gas line may be run from either side of the appliance provided the hole in the outer wrap does NOT exceed 2-1/2 inches in diameter and does not penetrate the firebox.

WARNING

Gas Leak Risk

Support control when attaching pipe to prevent bending gas line.

NOTE: The gap between the supply piping and gas access hole may be caulked with high temperature caulk or stuffed with non-combustible, un-faced insulation to prevent cold air infiltration.

Pressure requirements for appliance are shown in the table below. Minimum pressure must be met when other household gas appliances are operating.

Pressure

Natural Gas

Propane

Minimum Inlet

5.0 inches

11.0 inches

Pressure

w.c.

w.c.

Maximum Inlet

14.0 inches

14.0 inches

Gas Pressure

w.c.

w.c.

Manifold Pressure

3.5 inches

10.0 inches

w.c.

w.c.

 

Heat & Glo • SL-550 / 750 / 950TV-D2053-985 Rev. H • 9/06

19

Image 19
Contents What to do if you smell gas Homeowner Reference Information CongratulationsTable of Contents Models 1Listing and Code ApprovalsGlass Specifications BTU SpecificationsNon-Combustible Materials Specification High Altitude InstallationsCombustible Materials Specification Getting Started Design and Installation ConsiderationsNegative Pressure Inspect Appliance and Components Tools and Supplies NeededSelecting Appliance Location Framing and ClearancesClearances Constructing the Appliance ChaseClearances to Mantels or other Combustibles above Appliance Mantel ProjectionsVent Termination Minimum Clearances Termination LocationsVent Guidelines Vent Information and DiagramsVent System Configuration Minimum Vertical Feet Pipe Clearances to Combustibles Vent Clearances and FramingVertical Penetration Framing Appliance Preparation Installing Outside Air Kit Damper Assembly Gas and Electrical Connections Proper Positioning, Leveling and Securing of a Securing and Leveling ApplianceAttaching Vent to Firebox Installing Vent PipeAssembly of Vent Sections Securing Vent SectionsPressure Natural Gas Propane Gas InformationFuel Conversions Gas Connection Gas PressuresHigh Altitude Installations Optional Accessories Requirements Recommendation for WireConnecting to the Appliance Intellifire Ignition System WiringGround to Standing Pilot Ignition System WiringWall Switch Installation for Fan Optional Junction Box InstallationFacing Material FinishingRemove Shipping Materials Appliance SetupClean the Appliance AccessoriesPositioning the Logs Log Set Assembly LOGS-SL550-D Models SL-550TV-DTAB Locator Log Set Assembly LOGS-SL750-D Models SL-750TV-D, SL-950TV-D Notches Raised Flat Spots Grilles and Trim Glass AssemblyShutter Settings Screen MeshBefore operating this appliance have a qualified technician Operating InstructionsBefore Lighting Appliance Check Appliance DraftIntellifire Ignition Lighting ApplianceStanding Pilot Ignition For Your Safety Read Before Lighting InstructionsInitial Break-in Procedure Frequently Asked QuestionsAfter Appliance is Lit Symptom Possible Causes Corrective Actions TroubleshootingStanding Pilot Ignition System Symptom Possible Cause Corrective Action TroubleshootingIntellifire Ignition System Symptom Possible Causes Corrective Actions Before servicing Maintaining and Servicing ApplianceInspect Maintenance Tasks Appliance Dimensions Table Appliance Dimension DiagramReference Materials Log Set Assembly Service PartsAdditional service part numbers may appear on the following Service Parts ListSL-750TV-D SL-750TV-D 151 SL-950TV-DSL-950TV-D SL-550 / 750 / 950TV-D-IPI Common Parts Serial # Part Number SL-550 / 750 / 950TV-D 10-06 530-510A Limited Lifetime Warranty Heat & GLO GAS Appliance Products Limited Lifetime WarrantyDo not Discard this Manual Contact Information