2700-I WOOD INSERT (ACT)

R

TOP INSTALLATION INSTRUCTIONS

The top is packaged separately and shipped with the insert. Install on insert after unit is in place and the installation of the panels and trim are complete.

Push the top into place by aligning the pins into the slots and then press down into position.

panel Top

Top

Ashlip

Blower Motor

Figure 14.1

Blower cord may be attached on the left or right side

BLOWER INSTALLATION

Included in Kit: Blower motor and cord

Tools Needed: Phillips head screw driver

The 2700-I Insert comes standard with a blower housing already installed at the factory. All of the fasteners needed to install the optional blower are also installed on the insert. Order the optional Blower Assembly through your dealer, Part BK-7007. The blower cord can be installed on the right side or left side of the insert .

1.Remove the blower cover from the front of the unit by removing 4 screws, 2 at each end.

2.Remove the ashlip by removing the 2 screws on each side and pulling towards you. The blower housing is assembled and attached to the ashlip and will come out as one unit.

3.Remove the 4 nuts from the housing and attach the blower using the same 4 nuts. See circled area in Figure 14.2

4.Connect the white and black wires to blower motor termi- nals. Connect green ground wire to ground terminal.

5.Install strain relief onto power cord. Using a pair of pliers, squeeze strain relief and push through hole.

6.Plug in and test blower operation.

7.Re-install ashlip and blower cover.

8.Route power cord away from the unit. Do not route power cord cord under or in front of unit.

Figure 14.2

FAN SPEED CONTROL

ADJUSTMENT, IF NECESSARY*

*The fan Speed Control for this unit is adjusted at the factory, and normally does not require further adjustment.

NOTE: When the speed control is turned clockwise, it will click on to high speed. Continue to turn the speed control clockwise to decrease the speed. At full clockwise, the blower should blow gently, but should not stop.

1.With the unit plugged in, turn the Speed Control Knob to slow. (Full clockwise.)

2.Use a small screw driver to adjust the fan speed by turning the adjustment mechanism through the hole on the side of the Speed Control.

3.Adjust the speed so the fan runs slowly but does not stop. Turn clockwise to slow the fan and counter- clockwise to increase the speed.

Caution

Shock Risk.

Do NOT remove grounding prong from plug.

Plug directly into properly grounded 3 prong receptacle.

Route cord away from appliance.

Do NOT route cord under or in front of appliance.

Page 14

7007-161H

September 1, 2008

Image 14
Contents Hot glass will cause burns Advanced Combustion Technology ACTDo not Discard this Manual Fire RiskTest Lab & Report No 007Serial Number Model Name Manufactured DateTable of Contents United States and Canada DimensionsClearances to Combustibles Maximum Mantel Depth 10 inches 254mmListings Chimney HEIGHT/DRAFT CONT’D Installation recommendationsInstallation Chimney HEIGHT/DRAFTMaterial Design, Installation & LocationCalculating Alternate Floor Protection Firestopping Chimney RequirementsOvalizing Round Stainless Steel Liners Chimney to sheathingInstalling Outside Air Cover Box Fire Risk Asphyxiation RiskMasonry Fireplace Using DIRECT-CONNECT Method Metal Heat Circulating masonryUsa installations only Factory built zero clearance fireplaceLeveling Legs Installation in CanadaDoor Handle Assembly Masonry and HEAT-CIRCULATINGOutside AIR Installation Optional Quick Connect CollarAttaching Panels and Trim to the Insert Panel & Trim Assembly InstructionsPanel and Trim SET 13.1FAN Speed Control ADJUSTMENT, if Necessary TOP Installation InstructionsBlower Installation Shock RiskZero Clearance Adjustable Trim SUPPORT, 2 inch to 10 inch Injury Risk Gloves recommended May have sharp edgesBuilding a Fire Operation Wood Selection and StorageOverfiring Opacity Operating TipsBurn Rates ASH RemovalPrimary AIR System Air quality and your Quadra-Fire InsertSTART-UP AIR System When cleaning glass MaintenanceCreosote Chimney Cleaning Ceramic Blanket Brick replacement instructionsBaffle Removal & Installation BaffleDescription Exploded ViewCeramic Blanket Part Description Alphabetical OrderPart Description Alphabetical Order DescriptionAppliance Item # Accessories in alphabetically order Part NumberItem # Wood Insert, Advanced Combustible Technology ACT 2700-IService And Maintenance Log Date of Service Performed By Description of ServiceWarranty Policy CONDITIONS, Exclusions & Limitation of LiabilityHearth & Home Technologies Limited Warranty Cont’d Wood Insert ACT