FOR YOUR INFORMATION

START UP CONDITIONS

CONDENSATE

Whenever the water heater is filled with cold water, some condensate will form while the burner is on.A water heater may appear to be leaking when in fact the water is condensate. This usually happens when:

a.A new water heater is filled with cold water for the first time.

b.Burning gas produces water vapor in water heaters, particularly high efficiency models where flue temperatures are lower.

c.Large amounts of hot water are used in a short time and the refill water in the tank is very cold.

Moisture from the products of combustion condense on the cooler tank surfaces and form drops of water which may fall onto the burner or other hot surfaces to produce a “sizzling” or “frying” noise.

Because of the suddenness and amount of water, condensate water may be diagnosed as a “tank leak”. After the water in the tank warms up (about 1-2 hours), the condition should disappear.

Do not assume the water heater is leaking until there has been enough time for the water in the tank to warm up.

An undersized water heater will cause more condensation. The water heater must be sized properly to meet the family’s demands for hot water including dishwashers, washing machines and shower heads.

Excessive condensate may be noticed during the winter and early spring months when incoming water temperatures are at their lowest.

Good venting is essential for a gas fired water heater to operate properly as well as to carry away products of combustion and water vapor.

SMOKE/ODOR

It is not uncommon to experience a small amount of smoke and odor during the initial start-up. This is due to burning off of oil from metal parts, and will disappear in a short while.

THERMALEXPANSION

Water supply systems may, because of such events as high line pressure, frequent cut-offs, the effects of water hammer among others, have installed devices such as pressure reducing valves, check valves, back flow preventers, etc. to control these types of problems. When these devices are not equipped with an internal by-pass, and no other measures are taken, the devices cause the water system to be closed. As water is heated, it expands (thermal expansion) and closed systems do not allow for the expansion of heated water.

The water within the water tank expands as it is heated and increases the pressure of the water system. If the relieving point of the water heater’s temperature-pressure relief valve is reached, the valve will release the excess pressure. The temperature-pressure relief valve is not intended for the constant relief of thermal expansion. This is an unacceptable condition and must be corrected. It is recommended that any devices installed which could create a closed system have a by-pass and/or the system have an expansion tank or device to relieve the pressure built by thermal expansion in the water system. Expansion tanks are available through Sears stores and Sears Service Centers. Contact Sears Service Center for assistance in controlling these situations, see Figure 27.

Thermal Expansion Tank Specifications

 

Tank

Dimensions

Pipe

Model

Capacity

in Inches

Fitting

Number

In Gallons

Diameter

Length

On Tank

153.331020

2

8 (203 mm)

12-3/4 (323 mm)

3/4” Male

153.331050

5

11 (279 mm)

14-3/4 (375 mm)

3/4” Male

Expansion Tank Sizing Chart

 

Inlet*

Water Heater Capacity (Gallons)

 

Water

 

 

 

 

 

 

Pressure

30

40

50

66

80

Expansion

40psi

2

2

2

5

5

Tank

50psi

2

2

2

5

5

Capacity

60psi

2

2

5

5

5

Needed

70psi

2

2

5

5

5

 

80psi

2

5

5

5

5

 

 

 

 

 

 

 

*Highest recorded inlet water pressure in a 24 hour period or regulated water pressure.

NOTE: Expansion tanks are pre-charged with a 40 psi air charge. If the inlet water pressure is higher than 40 psi, the expansion tank’s air pressure must be adjusted to match that pressure, but must not be higher than 80 psi.

FIGURE27.

24

Image 24
Contents Economizer 6 GAS Water Heater Safe INSTALLATION, USE and Service Important DefinitionsSafety Precautions Table of Contents Product Specifications Preparing for the InstallationCustomer Responsibilities Materials and Basic Tools Needed Materials NeededTypical Installation Natural HOT Surface Igniter & Main BurnerPropane HOT Surface Igniter & Main Burner Installation Instructions Removing the Old Water HeaterFacts to Consider about the Location Insulation Blankets ALL AIR from Inside Buildings See Water Piping Hotter Water can ScaldValve and Pipe Insulation if supplied GAS Piping Blower Assembly Installation SequenceofinstallationSediment Traps Filling the Water HeaterPage Vent Connections to Blower Assembly Venting and InstallationCondensation Maximum Vent LengthsVent Terminal Installation VentingVertical Vent Through Roof Vertical Vent Termination RestrictionsVent Pipe Preparation Recommended BRUSH* Size for Primer Cement ApplicationsStepb StepeStepf StepgPowerbeforeservicing Operating InstructionsDo not try to light the burner by hand What to do if YOU Smell GASTemperature Regulation Temperature Setting Burns on Adult SkinFor Your Information Start UP ConditionsCondensate SMOKE/ODORService and Adjustment Operational ConditionsVenting System Inspection Burner Operation and InspectionBurner Cleaning TEMPERATURE-PRESSURE Relief Valve OperationHousekeeping Anode ROD InspectionDrain Valve Washer Replacement ServiceDraining Leakage Checkpoints Troubleshooting Guidelines LED StatusTroubleshooting Guidelines Repair Parts List Burner Assembly Outer Door AlternateEconomizer 6 GAS Water Heater Model Numbers Part Description 153.332040 153.332050Year Limited Warranty on Water Heater Year Exclusive Kenmore Labor WarrantyWarranty Service Sears Installation Service