Sears 153.332070, 153.332060 Operating Instructions, Do not try to light the burner by hand

Page 22

OPERATING INSTRUCTIONS

FOR YOUR SAFETY READ BEFORE OPERATING

WARNING: If you do not follow these instructions exactly, a fire or

explosion may result causing property damage, personal injury or loss of life.

BEFORE OPERATING: ENTIRE SYSTEM MUST BE FILLED WITH WATER AND AIR PURGED FROM ALL LINES.

A.This appliance does not have a pilot. It is equipped with an ignition device which automatically lights the burner.

Do NOT try to light the burner by hand.

B.BEFORE OPERATING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS:

Do not try to light any appliance.

Do not touch any electric switch;

Do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

If you cannot reach your gas supplier, call the fire

department.

C.Use only your hand to push in the gas control buttons. Never use tools. If the control buttons will not push in, don’t try to repair them, call a qualified service technician. Force or attempted repair may result in a fire or explosion.

D.Do not use this appliance if any part has been under water. Immediately contact a qualified installer or service agency to replace a flooded water heater. Do not attempt to repair the unit! It must be replaced!

OPERATING INSTRUCTIONS

1.STOP! Read the safety information above, on this label.

2.Set the thermostat to the lowest setting by first pressing

the COOLER and HOTTER buttons together and

holding for 1 second. Then press the COOLER button until the WARM indicator light appears.

3.Set the “ON/OFF” switch on the blower control box to the “OFF” position.

4.This appliance is equipped with a device which automatically lights the burner.

DO NOT TRY TO LIGHT THE BURNER BY HAND.

5. Wait five (5) minutes

to clear out any gas.

If you then smell gas,

STOP! Follow “B” in the

safety information above on this label. If you don’t smell gas, go to the next step.

6.Turn on all electrical power to the appliance.

7.Set thermostat to desired setting by first pressing the

COOLER and HOTTER buttons together and

holding for 1 second. Then press the HOTTER button.

8.If the appliance will not operate, follow the instructions “TO TURN OFF GAS TO APPLIANCE” and call your technician or gas supplier.

9.WATERTEMPERATUREADJUSTMENT

is approximately 120°F.

CAUTION: Hotter water increases the risk of scald injury. Consult the instruction manual before changing temperature.

WARNING: TURN OFFALLELECTRIC

POWERBEFORESERVICING

TO TURN OFF GAS TO APPLIANCE

1.Set the thermostat to the lowest setting by first pressing the COOLER and HOTTER buttons together and holding for 1 second. Then press the COOLER button until the WARM indicator light appears.

2.Set the ON/OFF switch on the blower control box to the “OFF” position.

3.Turn off all electric power to the appliance if service is to be performed.

22

Image 22
Contents Economizer 6 GAS Water Heater Safe INSTALLATION, USE and Service Important DefinitionsSafety Precautions Table of Contents Preparing for the Installation Product SpecificationsCustomer Responsibilities Materials and Basic Tools Needed Materials NeededNatural HOT Surface Igniter & Main Burner Typical InstallationPropane HOT Surface Igniter & Main Burner Installation Instructions Removing the Old Water HeaterFacts to Consider about the Location Insulation Blankets ALL AIR from Inside Buildings See Water Piping Hotter Water can ScaldValve and Pipe Insulation if supplied GAS Piping Sediment Traps Blower Assembly InstallationSequenceofinstallation Filling the Water HeaterPage Condensation Vent Connections to Blower AssemblyVenting and Installation Maximum Vent LengthsVent Terminal Installation VentingVertical Vent Through Roof Vertical Vent Termination RestrictionsVent Pipe Preparation Recommended BRUSH* Size for Primer Cement ApplicationsStepf StepbStepe StepgDo not try to light the burner by hand PowerbeforeservicingOperating Instructions What to do if YOU Smell GASTemperature Regulation Temperature Setting Burns on Adult SkinCondensate For Your InformationStart UP Conditions SMOKE/ODORVenting System Inspection Service and AdjustmentOperational Conditions Burner Operation and InspectionHousekeeping Burner CleaningTEMPERATURE-PRESSURE Relief Valve Operation Anode ROD InspectionService Drain Valve Washer ReplacementDraining Leakage Checkpoints Troubleshooting Guidelines LED StatusTroubleshooting Guidelines Economizer 6 GAS Water Heater Repair Parts ListBurner Assembly Outer Door Alternate Model Numbers Part Description 153.332040 153.332050Warranty Service Year Limited Warranty on Water HeaterYear Exclusive Kenmore Labor Warranty Sears Installation Service