CUSTOMER RESPONSIBILITIES
Thank You for purchasing a Kenmore water heater. Properly installed and maintained, it should give you years of trouble free service. If you should decide that you want the new water heater professionally installed by Sears call
Abbreviations Found In This Instruction Manual:
•CSA - Canadian Standards Association
•ANSI
•NFPA - National Fire ProtectionAssociation
•ASME - American Society of Mechanical Engineers
•GAMA - Gas Appliance Manufacturer’s Association
•UL - Underwriters Laboratories Inc.
This
2.The installation must conform with these instructions and the local code authority having jurisdiction. In the absence of local codes, installations shall comply with the National Fuel Gas CodeANSI Z223.1/ NFPA54 and the National Electrical Code, NFPA70.These publications are available from The National Fire Protection Association, 1 Batterymarch Park, Quincy, MA 02269.
3.The water heater when installed must be grounded in accordance with the local codes, or in the absence of local codes, the National Electrical Code NFPA70.
4.If after reading this manual you have any questions or do not understand any portion of the instructions, call the local gas utility or the Sears Service Center.
5.Carefully plan the place where you are going to put the water heater. Correct combustion, vent action, and vent pipe installation are very important in preventing death from possible carbon monoxide poisoning and fires.
PREPARING FOR THE INSTALLATION
1.Read the “Safety Precautions” section, page 3 of this manual first and then the entire manual carefully. If you don’t follow the safety rules, the water heater will not operate properly. It could cause
DEATH,SERIOUSBODILYINJURYAND/ORPROPERTYDAMAGE.
This manual contains instructions for the installation, operation, and maintenance of the
ATTEMPTING TO INSTALL OR OPERATE THE WATER HEATER.
Examine the location to ensure the water heater complies with the “Facts to Consider About the Location” section in this manual.
6.For California installation this water heater must be braced, anchored, or strapped to avoid falling or moving during an earthquake. See instructions for correct installation procedures. Instructions may be obtained from California Office of the State Architect, 400 P Street, Sacramento, CA 95814.
7.Massachusetts Code requires this water heater to be installed in accordance with Massachusetts
8.Complies with SCAQMD rule #1121 and districts having equivalent NOx requirements.
PRODUCT SPECIFICATIONS
| TANK |
|
| RECOVERY | MINIMUM |
|
| ||
| CAPACITY |
| INPUT | RATE GALS. | VENT PIPE | DIAMETER | DIMENSIONS IN | ||
MODEL | IN GALS. | TYPE OF | RATE | PERHOUR | INCHES | INCHES | INCHES (mm) HEIGHT | ||
NUMBER | (LTRS) | GAS | (Btu/hr) | @ 90°F RISE | (mm) | (mm) | TO JACKET TOP | ||
|
|
|
|
|
|
|
|
|
|
153.332040 | 40 | (151) | NATURAL | 40,000 | 44 | 2 | (51) | 18 1/2 (470) | 55 (1,397) |
|
|
|
|
|
|
|
|
|
|
153.332050 | 50 | (189) | NATURAL | 40,000 | 44 | 2 | (51) | 20 (508) | 56 3/4 (1,441) |
|
|
|
|
|
|
|
|
|
|
153.332060 | 40 | (151) | PROPANE | 40,000 | 44 | 2 | (51) | 18 1/2 (470) | 55 (1,397) |
|
|
|
|
|
|
|
|
|
|
153.332070 | 50 | (189) | PROPANE | 40,000 | 44 | 2 | (51) | 20 (508) | 56 3/4 (1,441) |
|
|
|
|
|
|
|
|
|
|
5