Sears 153.332050, 153.332060, 153.332070, 153.332040 Troubleshooting Guidelines, LED Status

Page 29

WATER HEATER CONTROL

TROUBLESHOOTING GUIDELINES

These guidelines should be used by a qualified service agent. Call Sears Service at 1-800-4-MY-HOME®(1-800-469-4663)

for assistance. Inform the associate that this is a “Flammable Vapor Ignition Resistant” Product.

LED STATUS

PROBLEM

 

SOLUTION

A

B C

An open earth ground circuit to the

1. Check that the earth ground connection is

ignition system.

 

properly connected.

 

 

 

2.

Check that the ground conductor on the

 

 

 

 

water heater is properly connected.

A

B C

Wiring error or a high resistance to

1.

Check for proper connection of line

earth ground.

 

neutral and hot wires.

 

 

 

 

 

 

2.

Check that the water heater is securely

 

 

 

 

connected to earth ground.

A

B C

Pressure switch remained closed longer

1.

Pressure switch wiring is incorrect.

 

 

than 5 seconds after the call for

2.

Replace pressure switch.

 

 

heat began.

 

 

A

B C

Pressure switch remained open longer

1.

Pressure switch wiring is incorrect.

than 5 seconds after the combustion

2.

Pressure switch tubing not connected

 

 

 

 

blower was energized.

 

correctly.

 

 

 

3.

Air intake or exhaust obstructed.

A

B C

Error in the hot surface ignitor circuit.

1.

Check that all wiring is correct and secure.

 

 

 

 

 

2.

Replace hot surface ignitor.

 

 

System in lockout.

1.

Gas supply is off or too low to operate.

A

B C

 

2.

Hot surface ignitor not positioned

 

 

correctly.

 

 

 

 

 

 

 

3.

Low voltage to the water heater.

 

 

 

4.

Electric polarity to unit is incorrect - test

 

 

 

 

and correct.

A

B C

Problem in the gas valve driver circuit.

1.

Turn power to the water heater off for

 

 

 

 

10 seconds and the back on.

 

 

 

2.

Replace gas control valve.

A

B C

Problem with the internal circuit.

1.

Turn power to the water heater off for

 

 

 

 

10 seconds and then back on.

 

 

 

2.

Replace gas control valve.

A

B C

Problem with the internal circuit.

1.

Turn power to the water heater off for

 

 

 

 

10 seconds and then back on.

 

 

 

2.

Replace gas control valve.

A

B C

Flame signal sensed out of

1.

Replace gas control valve.

 

 

 

 

proper sequence.

 

 

A

B C

 

 

 

 

 

ECO activated.

1.

Replace gas control valve.

A

B C

One of the temperature adjust

1.

Press and release each of the buttons

 

 

buttons stuck closed.

 

once.

 

 

 

2.

Replace gas control valve.

A

B C

Water temperature sensor is

1.

Check that all wiring is correct and secure.

 

 

 

 

either open or short circuited.

2.

Replace gas control valve.

A

B C

Unit shuts down and in lockout.

1.

Clean and reinstall the air intake screen.

 

 

 

2.

Clean and reinstall the lint screen on the

 

 

 

 

Blower assembly.

A

B C

Unit shuts down.

1.

Check for correct wiring to FV sensor.

 

 

 

2.

Check for open circuits to FV sensor.

 

 

 

3.

Replace FV sensor.

A

B C

Unit shuts down and in lockout.

1.

FV sensor detected presence of flammable vapors.

 

 

 

2.

Contact Sears Service Center to determine cause.

29

Image 29
Contents Economizer 6 GAS Water Heater Important Definitions Safe INSTALLATION, USE and ServiceSafety Precautions Table of Contents Customer Responsibilities Product SpecificationsPreparing for the Installation Materials Needed Materials and Basic Tools NeededPropane HOT Surface Igniter & Main Burner Typical InstallationNatural HOT Surface Igniter & Main Burner Removing the Old Water Heater Installation InstructionsFacts to Consider about the Location Insulation Blankets ALL AIR from Inside Buildings See Hotter Water can Scald Water PipingValve and Pipe Insulation if supplied GAS Piping Sequenceofinstallation Blower Assembly InstallationSediment Traps Filling the Water HeaterPage Venting and Installation Vent Connections to Blower AssemblyCondensation Maximum Vent LengthsVenting Vent Terminal InstallationVertical Vent Termination Restrictions Vertical Vent Through RoofRecommended BRUSH* Size for Primer Cement Applications Vent Pipe PreparationStepe StepbStepf StepgOperating Instructions PowerbeforeservicingDo not try to light the burner by hand What to do if YOU Smell GASTemperature Setting Burns on Adult Skin Temperature RegulationStart UP Conditions For Your InformationCondensate SMOKE/ODOROperational Conditions Service and AdjustmentVenting System Inspection Burner Operation and InspectionTEMPERATURE-PRESSURE Relief Valve Operation Burner CleaningHousekeeping Anode ROD InspectionDraining Drain Valve Washer ReplacementService Leakage Checkpoints LED Status Troubleshooting GuidelinesTroubleshooting Guidelines Burner Assembly Outer Door Alternate Repair Parts ListEconomizer 6 GAS Water Heater Model Numbers Part Description 153.332040 153.332050Year Exclusive Kenmore Labor Warranty Year Limited Warranty on Water HeaterWarranty Service Sears Installation Service