Sears 153.332040 Sediment Traps, Filling the Water Heater, Blower Assembly Installation

Page 15

The appliance and its gas connection must be leak tested before placing the appliance in operation.

The appliance and its individual Shut-off valve shall be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1/2 pound per square inch (3.5 kPa). It shall be isolated from the gas supply piping system by closing its individual manual Shut-off valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 pound per square inch (3.5 kPa).

Connecting the gas piping to the gas control valve of the water heater can be accomplished by either of the two methods shown in Figures 18 and 19.

FIGURE 18. GAS PIPING WITH

FLEXIBLECONNECTOR.

FIGURE 19. GAS PIPING WITH ALL

BLACK IRON PIPE TO GAS CONTROL.

SEDIMENT TRAPS

Contaminants in the gas lines may cause improper operation of the gas control valve that may result in fire or explosion. Before attaching the gas line be sure that all gas pipe is clean on the inside. To trap any dirt or foreign material in the gas supply line, a drip leg (sometimes called a sediment trap) must be incorporated in the piping. The drip leg must be readily accessible. Install in accordance with the “Gas Piping” section. Refer to the current edition of the National Fuel Gas Code, ANSI Z223.1/NFPA54.

A sediment trap shall be installed as close to the inlet of the water heater as practical at the time of water heater installation. The sediment trap shall be either a tee fitting with a capped nipple in the bottom outlet or other device recognized as an effective sediment trap. If a tee fitting is used, it shall be installed in conformance with one of the methods of installation shown in Figures 18 and 19.

FIGURE20.

FILLING THE WATER HEATER

Never use this water heater unless it is completely full of water. To prevent damage to the tank, the tank must be filled with water. Water must flow from the hot water faucet before turning “ON” gas to the water heater.

To fill the water heater with water:

1.Close the water heater drain valve by turning the handle to the right (clockwise). The drain valve is on the lower front of the water heater.

2.Open the cold water supply valve to the water heater.

NOTE: The cold water supply valve must be left open when the water heater is in use.

3.To insure complete filling of the tank, allow air to exit by opening the nearest hot water faucet. Allow water to run until a constant flow is obtained. This will let air out of the water heater and the piping.

4.Check all water piping and connections for leaks. Repair as needed.

BLOWER ASSEMBLY INSTALLATION

SEQUENCEOFINSTALLATION

1. Thispowerventedwaterheatercomeswiththeblowerassemblyinstalled.

2After the unit is set in place, make sure the blower assembly is still mounted securely and the air intake screen of the blower assembly is installed in the dilution air opening. Also make sure the drain port of the rubber boot vent adapter is capped off. Lastly, make sure there is no damage to the blower.

3.Make sure there is no packing material in the discharge of the blower or the intake of the dilution air restrictor, see Figure 21.

15

Image 15
Contents Economizer 6 GAS Water Heater Important Definitions Safe INSTALLATION, USE and ServiceSafety Precautions Table of Contents Product Specifications Preparing for the InstallationCustomer Responsibilities Materials Needed Materials and Basic Tools NeededTypical Installation Natural HOT Surface Igniter & Main BurnerPropane HOT Surface Igniter & Main Burner Removing the Old Water Heater Installation InstructionsFacts to Consider about the Location Insulation Blankets ALL AIR from Inside Buildings See Hotter Water can Scald Water PipingValve and Pipe Insulation if supplied GAS Piping Filling the Water Heater Blower Assembly InstallationSequenceofinstallation Sediment TrapsPage Maximum Vent Lengths Vent Connections to Blower AssemblyVenting and Installation CondensationVenting Vent Terminal InstallationVertical Vent Termination Restrictions Vertical Vent Through RoofRecommended BRUSH* Size for Primer Cement Applications Vent Pipe PreparationStepg StepbStepe StepfWhat to do if YOU Smell GAS PowerbeforeservicingOperating Instructions Do not try to light the burner by handTemperature Setting Burns on Adult Skin Temperature RegulationSMOKE/ODOR For Your InformationStart UP Conditions CondensateBurner Operation and Inspection Service and AdjustmentOperational Conditions Venting System InspectionAnode ROD Inspection Burner CleaningTEMPERATURE-PRESSURE Relief Valve Operation HousekeepingDrain Valve Washer Replacement ServiceDraining Leakage Checkpoints LED Status Troubleshooting GuidelinesTroubleshooting Guidelines Model Numbers Part Description 153.332040 153.332050 Repair Parts ListBurner Assembly Outer Door Alternate Economizer 6 GAS Water HeaterSears Installation Service Year Limited Warranty on Water HeaterYear Exclusive Kenmore Labor Warranty Warranty Service