Trane Communicating Thermostat Points List

Table 45. Points Available in the TStat_HeatPump_Trane Template (continued)

 

 

 

 

Data

 

TStat Device Point

 

Point

Normaliza-

Tracer SC Point Name

Name

Point Type

Instance

tion

 

Heating Lockout

AV

50

 

 

Temperature

 

 

 

 

 

 

 

 

 

 

 

Cooling Lockout

AV

51

 

 

Temperature

 

 

 

 

 

 

 

 

 

 

 

Password Value

AV

59

 

 

 

 

 

 

 

Power-up Delay

AV

60

 

 

 

 

 

 

 

Unoccupied Time

AV

68

 

 

 

 

 

 

 

High Balance Point

AV

82

 

 

 

 

 

 

 

Low Balance Point

AV

83

 

 

 

 

 

 

 

AUX

BI

24

 

 

 

 

 

 

 

DI 1 Status

BI

31

 

 

 

 

 

 

 

DI 2 Status

BI

32

 

 

 

 

 

 

 

Room Temp Override

BV

8

 

 

 

 

 

 

 

Outdoor Temp Override

BV

10

 

 

 

 

 

 

 

Aux Contact

BV

56

 

 

 

 

 

 

 

Menu Scroll

BV

57

 

 

 

 

 

 

 

Fan Purge Delay

BV

64

 

 

 

 

 

 

 

Comfort Mode

BV

84

 

 

 

 

 

 

 

Reversing Valve

BV

85

 

 

Configuration

 

 

 

 

 

 

 

 

 

 

 

Compressor Interlock

BV

86

 

 

 

 

 

 

 

Heating CPH

MV

53

 

 

 

 

 

 

 

Cooling CPH

MV

54

 

 

 

 

 

 

 

Anticycle

MV

63

 

 

 

 

 

 

 

DI 1 Configuration

MV

65

 

 

 

 

 

 

 

DI 2 Configuration

MV

66

 

 

 

 

 

 

 

Proportional Band

MV

67

 

 

 

 

 

 

 

Heat Pump Stages

MV

75

 

 

 

 

 

 

TStat_RTU_Trane Template

Table 46. Points Available in the TStat_RTU_Trane Template

 

 

 

 

Data

 

TStat Device Point

 

Point

Normaliza-

Tracer SC Point Name

Name

Point Type

Instance

tion

Cool Output 1 Status

Y1 Cool

BI

26

 

 

 

 

 

 

Cool Output 2 Status

Y2 Cool

BI

27

 

 

 

 

 

 

Diagnostic Present

Service Alarm

BI

39

 

 

 

 

 

 

Dirty Filter Alarm

Filter Alarm

BI

38

 

 

 

 

 

 

Discharge Air Temperature

Supply Temperature

AI

16

 

 

 

 

 

 

Display Temperature Scale

Temperature Scale

BV

47

 

 

 

 

 

 

Economizer Minimum Position Setpoint

Economizer Minimum

AV

78

 

BAS

Position

 

 

 

 

 

 

 

 

 

Economizer Mixed Air Enable Setpoint

Mixed Air Setpoint

AV

80

 

BAS

 

 

 

 

Economizer Outdoor Air Enable

Economizer Changeover

AV

77

 

Setpoint BAS

Setpoint

 

 

 

 

 

 

 

 

 

Fan Mode BAS

Fan Mode

MV

15

 

 

 

 

 

 

Fan Output Status

G Fan

BI

25

 

 

 

 

 

 

Heat Cool Mode Request

System Mode RTU

MV

14

Yes

 

 

 

 

 

Heat Output 1 Status

W1 Heat

BI

28

 

 

 

 

 

 

44

BAS-SVP10A-EN

Image 44
Contents Integration Manual Copyright Table of Contents Objects and Parameters Tracer SC Network Configuration Overview Product DescriptionHow To Information Related DocumentsPlanning Your Integration OverviewSupported BACnet Services Default Device Name and Default Device IDSummary of BACnet Objects BACnet Interoperability Building BlocksFan Coil Objects Summary of BACnet ObjectsX13511541010 and -2010 Rooftop and Heat Pump Models Objects table for fan coilsOutput Configuration Options GRP PresentValue R General Options GRP PresentValue RRooftop and Heat Pump Objects Rooftop and heat pump ungrouped objectsType Rooftop Object Name Instance Object Property 1010 2010Heatpump Model GRP PresentValue R Configuration Options Stages Configuration GRP PresentValue R OptionsEconomizer Model GRP PresentValue R Configuration Options Standard Object Types Supported Standard object types supportedConfiguration Objects for Fan Coils Configuration Objects for Rooftop and Heat Pump UnitsList of Proprietary Properties Proprietary PropertiesList of property value range restrictions BACnet Object PropertiesFan Coil Object Properties Object Name Object ID BACnet Index Text Default value BACnet Object PropertiesList of property enumeration sets for MV objects Table NoteObject Name Object ID BACnet Index Text Default value Function MV58 MV17 Index State Text Index Default ValueMV15 Sequence of Operation values for Note Additional MV valuesFunction MV26 BV75 Value MV52 Index MV27 Object Name State Text IndexHour Hours Rooftop and Heat Pump Object Properties Object Type Under Range Object NameValue Over Range ValueList of property enumeration sets for BI and BV objects Object Type Object Name Instance InactiveText ActiveTextUnder Range Instance Value Over Range ValueObject Name Instance BACnet Index Text Object TypeNone RemNSB DI1 Configuration MV65 RemOVR Filter Service Objects You Can Use in Site Graphics Fan CoilsRooftop and Heat Pump Units Objects You Can Use in Site GraphicsWiring Requirements for Communicating Thermostats BACnet MS/TP Link WiringWiring Requirements for Communicating Thermostats Daisy chain configuration for BACnet wiringProduct Specifications Communicating Thermostat SpecificationsNetwork Adapter DetailsTroubleshooting Causes and solutions for error conditionPossible Cause Solution Communicating Thermostat Status LEDsFan Coils Additional Information and ConsiderationsMS/TP Network Integration Objects and Parameters Additional Information and Considerations Tracer SC Network Configuration No automatic installationNight Purge disabled No priority arrayHeat only/cool only Parameters not supportedInappropriate text on graphic displays No active setpoint or heat/cool mode dataDischarge air temp requirements BAS-SVP10A-EN Template TStatFanCoilTrane Data NormalizationExample Occupancy Request Data Normalization Tracer SC writing to the fan coil Heat Cool Mode RequestReading from fan coil to Tracer SC Heat Cool Mode Request Tracer SC Point name Supply Fan Staged Speed Status Tracer SC writing to the fan coil Fan Mode BASReading from fan coil to tracer SC Fan Mode BAS Template TStatHeatPumpTrane Tracer SC writing to the heat pump Occupancy StatusReading from heat pump to Tracer SC Occupancy Status Tracer SC writing to the heat pump Occupancy RequestTracer SC writing to the heat pump Heat Cool Mode Request Reading from Heat Pump to Tracer SC Heat Cool Mode RequestTemplate TStatRTUTrane Tracer SC writing to the rooftop unit Occupancy StatusTracer SC writing to the rooftop unit Occupancy Request Reading from rooftop unit to Tracer SC Occupancy RequestTrane Communicating Thermostat Points List TStatFanCoilTranePoints Available in the TStatFanCoilTrane Template TStat Device PointTStatHeatPumpTrane Template Trane Communicating Thermostat Points ListPoints Available in the TStatHeatPumpTrane Template Point Type Instance TionTStatRTUTrane Template Points Available in the TStatRTUTrane TemplatePoint Type YesAUX Page

BAS-SVP10A-EN, Trane Communicating Thermostats (BACnet) specifications

The Trane BAS-SVP10A-EN is a part of the Trane Communicating Thermostats series designed to facilitate efficient and effective building temperature control in HVAC systems. These thermostats work with BACnet (Building Automation and Control Network), a widely adopted communication protocol in building automation for networked control of HVAC systems, lighting, access control, and fire systems.

One of the standout features of the Trane BAS-SVP10A-EN is its compatibility with various Trane equipment and other BACnet-compliant devices. This versatility allows for seamless integration into existing building systems, enhancing operational efficiency. The thermostat is designed to support zoning applications, offering precise temperature control to individual areas or rooms, thus significantly improving occupant comfort while also minimizing energy consumption.

The Trane communicating thermostat is built with advanced technologies that ensure optimal performance. It utilizes digital communication, enabling real-time data exchange between the thermostat and the HVAC system. This capability enhances the responsiveness of the HVAC system, allowing it to adjust more accurately to changing environmental conditions. The thermostat features an intuitive interface with a clear display, making it user-friendly for building occupants and facility managers alike.

Another important characteristic is its advanced scheduling capabilities. Users can program customized heating and cooling schedules, promoting energy savings while maintaining comfort levels. Additionally, its remote access feature allows for monitoring and control from smartphones, tablets, or computers, making it convenient for users to manage their HVAC systems from virtually anywhere.

The Trane BAS-SVP10A-EN also boasts robust diagnostic and reporting functions. It can provide feedback on system performance, enabling proactive maintenance and troubleshooting, which increases the reliability of HVAC operations. Overall, the Trane Communicating Thermostat represents a sophisticated solution for modern building management, focusing on comfort, energy efficiency, and ease of integration into existing systems. With its commitment to leveraging cutting-edge technology, Trane continues to lead in providing innovative solutions for heating, ventilation, and air conditioning needs in diverse building environments.