Trane Comprehensive Guide to BACnet MS/TP Thermostat and BACnet Terminator

Page 6

Overview

Related Documents

See the following documents for Communicating Thermostat installation and configuration information.

Trane Communicating Thermostats for Heat Pump Control User Guide (BAS-SVU10x-EN)

Trane Communicating Thermostats for Rooftop Control User Guide (BAS-SVU11x-EN)

Trane Communicating Thermostats for Fan Coil Control User Guide (BAS-SVU12x-EN) See the following documents for Tracer SC network integration information.

Tracer™ SC System Controller Installation and Setup (BAS-SVX31x-EN)

Tracer™ BACnet™ Terminator Installation (X39641151-01x)

Unit Controller Wiring Guide For the Tracer SC™ System Controller (BAS-SVN03x-EN

Finally, see the following documents for information about equipment including fan coils, rooftop units, and heat pumps.

Communicating Thermostats for Rooftop and Heat Pump Control Product Data Sheet (BAS-PRC064-EN)

Communicating Thermostats for Fan Coil Control Product Data Sheet (BAS-PRC065-EN)

All these documents are available from your Trane distributor.

Planning Your Integration

Study the following information presented in the chapters of this guide as you plan the work:

Communicating Thermostat BACnet objects (points) and their properties (ranges, values, and enumeration sets for points). (See “Summary of BACnet Objects,” p. 7. and “BACnet Object Properties,” p. 14.)

Tips and considerations presented in “Additional Information and Considerations,” p. 29. If your network is managed by a Tracer SC, pay special attention to “Tracer SC Network Configuration,” p. 32.

Wiring instructions in “Wiring Requirements for Communicating Thermostats,” p. 25.

Available Graphical User Interface (GUI) objects that you can use in graphics presented in “Objects You Can Use in Site Graphics,” p. 23.

“How To” Information

The following “how to” questions are described or clarified either in this manual or in other documents cited in this table.

Question

Information Location or Answer

How do I set up alarming in Tracer SC?

See the Tracer™ SC System Controller Installation and

Setup Manual (BAS-SVX31x-EN)

 

 

 

How do I set the MAC address of the Trane Communicating

See “Default Device Name and Default Device ID,” p. 7.

Thermostat?

Also, see the appropriate User Guide listed in “Related

 

Documents” on this page.

 

 

How do I install a Trane Communicating Thermostat on the

See “No automatic installation,” p. 32.

Tracer SC link?

 

 

 

6

BAS-SVP10A-EN

Image 6
Contents Integration Manual Copyright Table of Contents Objects and Parameters Tracer SC Network Configuration Overview Product DescriptionPlanning Your Integration How To InformationRelated Documents OverviewSummary of BACnet Objects Supported BACnet ServicesDefault Device Name and Default Device ID BACnet Interoperability Building BlocksX13511541010 and -2010 Rooftop and Heat Pump Models Fan Coil ObjectsSummary of BACnet Objects Objects table for fan coilsOutput Configuration Options GRP PresentValue R General Options GRP PresentValue RType Rooftop Rooftop and Heat Pump ObjectsRooftop and heat pump ungrouped objects Object Name Instance Object Property 1010 2010Stages Configuration GRP PresentValue R Options Economizer Model GRP PresentValue R Configuration OptionsHeatpump Model GRP PresentValue R Configuration Options Standard Object Types Supported Standard object types supportedList of Proprietary Properties Configuration Objects for Fan CoilsConfiguration Objects for Rooftop and Heat Pump Units Proprietary PropertiesBACnet Object Properties Fan Coil Object PropertiesList of property value range restrictions List of property enumeration sets for MV objects Object Name Object ID BACnet Index Text Default valueBACnet Object Properties Table NoteMV15 Sequence of Operation values for Note Object Name Object ID BACnet Index Text Default valueFunction MV58 MV17 Index State Text Index Default Value Additional MV valuesFunction MV26 BV75 Value MV52 Index MV27 Object Name State Text IndexHour Hours Value Rooftop and Heat Pump Object PropertiesObject Type Under Range Object Name Over Range ValueUnder Range List of property enumeration sets for BI and BV objectsObject Type Object Name Instance InactiveText ActiveText Instance Value Over Range ValueObject Name Instance BACnet Index Text Object TypeNone RemNSB DI1 Configuration MV65 RemOVR Filter Service Objects You Can Use in Site Graphics Fan CoilsRooftop and Heat Pump Units Objects You Can Use in Site GraphicsWiring Requirements for Communicating Thermostats BACnet MS/TP Link WiringWiring Requirements for Communicating Thermostats Daisy chain configuration for BACnet wiringNetwork Adapter Product SpecificationsCommunicating Thermostat Specifications DetailsPossible Cause Solution TroubleshootingCauses and solutions for error condition Communicating Thermostat Status LEDsAdditional Information and Considerations MS/TP Network IntegrationFan Coils Objects and Parameters Additional Information and Considerations Night Purge disabled Tracer SC Network ConfigurationNo automatic installation No priority arrayHeat only/cool only Parameters not supportedNo active setpoint or heat/cool mode data Discharge air temp requirementsInappropriate text on graphic displays BAS-SVP10A-EN Data Normalization Example Occupancy RequestTemplate TStatFanCoilTrane Tracer SC writing to the fan coil Heat Cool Mode Request Reading from fan coil to Tracer SC Heat Cool Mode RequestData Normalization Tracer SC writing to the fan coil Fan Mode BAS Reading from fan coil to tracer SC Fan Mode BASTracer SC Point name Supply Fan Staged Speed Status Reading from heat pump to Tracer SC Occupancy Status Template TStatHeatPumpTraneTracer SC writing to the heat pump Occupancy Status Tracer SC writing to the heat pump Occupancy RequestTemplate TStatRTUTrane Tracer SC writing to the heat pump Heat Cool Mode RequestReading from Heat Pump to Tracer SC Heat Cool Mode Request Tracer SC writing to the rooftop unit Occupancy StatusTracer SC writing to the rooftop unit Occupancy Request Reading from rooftop unit to Tracer SC Occupancy RequestPoints Available in the TStatFanCoilTrane Template Trane Communicating Thermostat Points ListTStatFanCoilTrane TStat Device PointPoints Available in the TStatHeatPumpTrane Template TStatHeatPumpTrane TemplateTrane Communicating Thermostat Points List Point Type Instance TionPoint Type TStatRTUTrane TemplatePoints Available in the TStatRTUTrane Template YesAUX Page

BAS-SVP10A-EN, Trane Communicating Thermostats (BACnet) specifications

The Trane BAS-SVP10A-EN is a part of the Trane Communicating Thermostats series designed to facilitate efficient and effective building temperature control in HVAC systems. These thermostats work with BACnet (Building Automation and Control Network), a widely adopted communication protocol in building automation for networked control of HVAC systems, lighting, access control, and fire systems.

One of the standout features of the Trane BAS-SVP10A-EN is its compatibility with various Trane equipment and other BACnet-compliant devices. This versatility allows for seamless integration into existing building systems, enhancing operational efficiency. The thermostat is designed to support zoning applications, offering precise temperature control to individual areas or rooms, thus significantly improving occupant comfort while also minimizing energy consumption.

The Trane communicating thermostat is built with advanced technologies that ensure optimal performance. It utilizes digital communication, enabling real-time data exchange between the thermostat and the HVAC system. This capability enhances the responsiveness of the HVAC system, allowing it to adjust more accurately to changing environmental conditions. The thermostat features an intuitive interface with a clear display, making it user-friendly for building occupants and facility managers alike.

Another important characteristic is its advanced scheduling capabilities. Users can program customized heating and cooling schedules, promoting energy savings while maintaining comfort levels. Additionally, its remote access feature allows for monitoring and control from smartphones, tablets, or computers, making it convenient for users to manage their HVAC systems from virtually anywhere.

The Trane BAS-SVP10A-EN also boasts robust diagnostic and reporting functions. It can provide feedback on system performance, enabling proactive maintenance and troubleshooting, which increases the reliability of HVAC operations. Overall, the Trane Communicating Thermostat represents a sophisticated solution for modern building management, focusing on comfort, energy efficiency, and ease of integration into existing systems. With its commitment to leveraging cutting-edge technology, Trane continues to lead in providing innovative solutions for heating, ventilation, and air conditioning needs in diverse building environments.