Bryant T6-PRH-A installation instructions Control Module Wiring Guide

Page 15

6.Match and connect equipment wires to proper terminals of each connector block, being careful not to over tighten the screws. Correct polarity must be observed when connecting the two wires from the Equipment Control Module to the Thermidistat Control mounting base. If wires are con- nected incorrectly, the Display Module will not operate. See Fig. 7, 8 and 9.

A08072

Fig. 7 - Control Module Wiring Guide

SRed is V+ S Black is Vg

15

Image 15
Contents Installation Instructions Safety Considerations Table of ContentsIntroduction Power Installation ConsiderationsHumidify Equipment and Connections ModelsDehumidify Equipment and Connections Outdoor Temperature SensorTwo-Piece Thermidistat Control Configuration Remote Indoor Temperature SensorT6-PRH-A Carton Contents InstallationThermidistat Control Location T6-NRH-A Carton ContentsInstall Thermidistat Control Unit Damage Hazard Environmental Hazard Two-Piece InstallationPress Tabs to Remove Backplate Backplate Mounting Control Module Wiring Guide Secure Wires to Terminal Strip Attach Display to Backplate Equipment Control Module on Equipment Standoff Cover on Equipment Control Module Single-Piece Installation Equipment Control Module Reattach Display Module Set Thermidistat Control Configuration Page To Enter Configuration Mode Configuration Options -Selection Option 02 Clean Filter TimerOption 01 Equipment Type Option 07 Zoning Option 03 Fahrenheit/CentigradeOption 04 Fan G On With W/W1 Option 06 Cooling Lockout Below 55F/13COption 10 Reversing Valve Option 08 Auxiliary Heat Lockout TemperatureOption 11 Deadband Setting Between Heat & Cool Option 12 Smart RecoveryOption 13 Room Air Temperature Offset Adjust Option 14 Humidity Display Offset Adjust Option 15 Enable Auto ModeOption 16 Maximum Cycles Per Hour Option 17 Time Between Equipment Stages Option 18 Backlight ConfigurationPage Option 20 Outdoor Air Temperature Offset Adjustment Option 21 Keypad Lockout programmable models onlyOption 21 Keypad Lockout non-programmable models only Default is of off Page Option 26 Minimum Cooling Setpoint Option 27 Maximum Heating SetpointOption 28 UV Light Reminder Option 30 Programmable Fan programmable models only Option 29 Humidifier Pad ReminderPage Option 33 Single or Two-Piece Installation Option 40 Humidify FanOption 41 Variable Speed Blower Option 43 Intelligent Heat Staging Option 42 Variable Speed Super DehumidificationOption 44 Super Comfort Heat System START-UP and Checkout Option 99 Reset to Factory DefaultsTo Test FAN Energy Star Default Schedule Final SettingsPage Humidity Control Features HumidificationHumidification Selections Additional Humidify Comments DehumidificationTo Select Humidification programmable To Select Humidification non-programmablePage Auto Humidity Dehumidify Output and Equipment Connections Additional Dehumidify CommentsVacation programmable models only Vacation Dehumidification Vacation Setpoints Default ValuesVacation Setpoints Vacation HumidificationOperational Information TimersEquipment On Indicators Heat/Cool Setpoints Desired TemperatureThree-Minute Minimum on Time Programmable Fan programmable models only Humidify and Dehumidify IndicatorsEmergency Heat Mode Auto ChangeoverError Codes TroubleshootingPage Equipment Configuration Outputs Cool Heat Display to Equipment Control Module Connection Wiring DiagramsFV/FK Fan Coil with 2-Stage Heat Pump Typical Fan Coil with Heat Pump OAT RRS Srtn FV/FK Fan Coil w/2-Stage Air Conditioner Typical Fan Coil with Air Conditioner A08128 FV/FK Fan Coil with 1-Stage Heat Pump Typical Fan Coil Heating Only Thermidistat Control w/Dry Contact Control for Fan Run Time FV/FK Fan Coil with 1-Stage Air Conditioner Typical Fan Coil Cooling Only Variable Speed/Multi-Stage Furnace with 2-Stage Heat Pump Single-Stage Furnace with Heat Pump Hybrid Heat Variable Speed/Multi-Stage Furnace w/2-Stage Air Conditioner Single-Stage Furnace with Air Conditioner Variable Speed/Multi-Stage Furnace w/Single-Stage Heat Pump Single-Stage Furnace Heating Only A08140 Single-stage Furnace with Air Conditioner and Split Power Mode Settings Thermidistat Control Configuration RecordConfiguration Options Configuration Options Catalog No IIT6---PRH---03