Bryant T6-PRH-A installation instructions Default is of off

Page 35

1 — The user has access to modify Home, Sleep, Away, and UP/DOWN setpoints.

2 — The entire keypad is locked. When a button is pressed, the backlight will turn on but none of the operating parameters will be changed.

When the keypad lock selection is turned on, the padlock icon will be displayed. To unlock the keypad, press and hold the UP/DOWN buttons simultaneously for five seconds. When the keypad is unlocked, the padlock icon will turn off. The keypad will remain unlocked for two minutes after the last button press. After two minutes with no button presses, the keypad will lock again. The keypad will not lock in the software configuration mode or in the installer test mode.

Default is OF (off).

Option 22 — High Cool Latch Temperature (only available if outdoor sensor is present)

An outdoor sensor is required for high cool latch feature.

This selection is only available when Option 1 is set to H2, A2, or h2 and when Option 7 (zoning) is set to OF (off). Configuration settings are OF (off), 80, 85, 90, 95, 100, 105, 110, On.

OF (off) — Cooling always starts in low stage (Y1) and stages up to high stage (Y1 and Y/Y2) when demand is sufficient and staging timer constraints have been satisfied.

80-110_F/27-43_C — Outdoor temperature above which both first and second stages of the compressor are energized to satisfy all cooling demands. When a cycle starts under a high cool latch, it will finish the cooling cycle on high stage. If the cooling equipment is energized to satisfy a dehumidify demand only (no cooling demand), the latch will not be applied.

35

Image 35
Contents Installation Instructions Safety Considerations Table of ContentsIntroduction Power Installation ConsiderationsHumidify Equipment and Connections ModelsDehumidify Equipment and Connections Outdoor Temperature SensorTwo-Piece Thermidistat Control Configuration Remote Indoor Temperature SensorT6-PRH-A Carton Contents InstallationThermidistat Control Location T6-NRH-A Carton ContentsInstall Thermidistat Control Unit Damage Hazard Environmental Hazard Two-Piece InstallationPress Tabs to Remove Backplate Backplate Mounting Control Module Wiring Guide Secure Wires to Terminal Strip Attach Display to Backplate Equipment Control Module on Equipment Standoff Cover on Equipment Control Module Single-Piece Installation Equipment Control Module Reattach Display Module Set Thermidistat Control Configuration Page To Enter Configuration Mode Option 01 Equipment Type Configuration Options -SelectionOption 02 Clean Filter Timer Option 07 Zoning Option 03 Fahrenheit/CentigradeOption 04 Fan G On With W/W1 Option 06 Cooling Lockout Below 55F/13COption 10 Reversing Valve Option 08 Auxiliary Heat Lockout TemperatureOption 13 Room Air Temperature Offset Adjust Option 11 Deadband Setting Between Heat & CoolOption 12 Smart Recovery Option 16 Maximum Cycles Per Hour Option 14 Humidity Display Offset AdjustOption 15 Enable Auto Mode Option 17 Time Between Equipment Stages Option 18 Backlight ConfigurationPage Option 21 Keypad Lockout non-programmable models only Option 20 Outdoor Air Temperature Offset AdjustmentOption 21 Keypad Lockout programmable models only Default is of off Page Option 28 UV Light Reminder Option 26 Minimum Cooling SetpointOption 27 Maximum Heating Setpoint Option 30 Programmable Fan programmable models only Option 29 Humidifier Pad ReminderPage Option 41 Variable Speed Blower Option 33 Single or Two-Piece InstallationOption 40 Humidify Fan Option 43 Intelligent Heat Staging Option 42 Variable Speed Super DehumidificationOption 44 Super Comfort Heat System START-UP and Checkout Option 99 Reset to Factory DefaultsTo Test FAN Energy Star Default Schedule Final SettingsPage Humidification Selections Humidity Control FeaturesHumidification Additional Humidify Comments DehumidificationTo Select Humidification programmable To Select Humidification non-programmablePage Auto Humidity Dehumidify Output and Equipment Connections Additional Dehumidify CommentsVacation programmable models only Vacation Dehumidification Vacation Setpoints Default ValuesVacation Setpoints Vacation HumidificationOperational Information TimersThree-Minute Minimum on Time Equipment On IndicatorsHeat/Cool Setpoints Desired Temperature Programmable Fan programmable models only Humidify and Dehumidify IndicatorsEmergency Heat Mode Auto ChangeoverError Codes TroubleshootingPage Equipment Configuration Outputs Cool Heat Display to Equipment Control Module Connection Wiring DiagramsFV/FK Fan Coil with 2-Stage Heat Pump Typical Fan Coil with Heat Pump OAT RRS Srtn FV/FK Fan Coil w/2-Stage Air Conditioner Typical Fan Coil with Air Conditioner A08128 FV/FK Fan Coil with 1-Stage Heat Pump Typical Fan Coil Heating Only Thermidistat Control w/Dry Contact Control for Fan Run Time FV/FK Fan Coil with 1-Stage Air Conditioner Typical Fan Coil Cooling Only Variable Speed/Multi-Stage Furnace with 2-Stage Heat Pump Single-Stage Furnace with Heat Pump Hybrid Heat Variable Speed/Multi-Stage Furnace w/2-Stage Air Conditioner Single-Stage Furnace with Air Conditioner Variable Speed/Multi-Stage Furnace w/Single-Stage Heat Pump Single-Stage Furnace Heating Only A08140 Single-stage Furnace with Air Conditioner and Split Power Mode Settings Thermidistat Control Configuration RecordConfiguration Options Configuration Options Catalog No IIT6---PRH---03

T6-PRH-A specifications

The Bryant T6-PRH-A is a cutting-edge thermostat designed for modern heating and cooling systems, making it a popular choice among homeowners seeking efficiency and comfort. This smart thermostat integrates advanced technologies that enhance usability and control over home climate management.

One of the main features of the T6-PRH-A is its Wi-Fi capability, which allows users to control their home heating and cooling systems from anywhere using a smartphone or tablet. The intuitive mobile app is compatible with both iOS and Android devices, enabling real-time adjustments and monitoring of indoor temperatures. This remote access is especially beneficial for those who want to ensure their home is at a comfortable temperature before arriving, thus increasing convenience and comfort.

Another key characteristic of the T6-PRH-A is its compatibility with a variety of heating and cooling systems. It can seamlessly integrate with HVAC systems, heat pumps, and even multi-stage installations. This versatility is crucial for homeowners with unique system requirements, ensuring that the T6-PRH-A can fulfill diverse heating and cooling needs.

The thermostat also features a user-friendly touchscreen interface, which simplifies navigation and temperature adjustments. Users can easily program schedules, set temperature preferences, and review energy usage statistics directly on the device. This promotes energy-efficient practices by allowing homeowners to visualize their consumption and make informed decisions about their heating and cooling habits.

Moreover, the T6-PRH-A supports geofencing technology, which can detect when homeowners are away from the residence. The thermostat automatically adjusts the temperature based on the occupants' location, conserving energy when the home is unoccupied and ensuring a comfortable environment upon return.

Additionally, energy-saving modes such as Smart Recovery help in optimizing comfort without unnecessary energy expenditure. This feature allows the thermostat to learn how long it takes to heat or cool a space, starting the process early to achieve the desired temperature at the specified time while minimizing energy usage.

In summary, the Bryant T6-PRH-A is a sophisticated thermostat equipped with an array of features designed to maximize comfort, efficiency, and control over home climate. Its Wi-Fi connectivity, user-friendly interface, compatibility with various systems, and intelligent energy-saving technologies make it an ideal choice for today’s tech-savvy homeowners.