pressed for fan to turn On and off. On some fan coils, fan continues to operate for 90 sec after G signal is removed.
Final Settings
Be sure to press DONE to exit installer setup mode. If the system is to be left in operation after installation is complete, use MODE button to select between HEAT, COOL, or AUTO to provide desired operation of heating, cooling, or auto.
On the programmable models, the default setpoints and programmed schedule conform to the Energy Starr requirements of the U.S. Department of Energy for both heating and cooling. These provide energy saving temperature settings. Refer to Table 1.
Table 1 – Energy Star Default Schedule
SCHEDULE | HEAT | COOL |
Wake 6:00 AM | 68_F/20_C | 78_F/26_C |
Day 8:00 AM | 60_F/16_C | 85_F/29_C |
Evening 5:00 PM | 68_F/20_C | 78_F/26_C |
Sleep 10:00 PM | 60_F/16_C | 82_F/28_C |
If the programmed schedule is to be used, make sure the triangle icon next to the FOLLOW SCHEDULE icon is turned on. Pressing the Schedule button will cycle the triangle icon through the FOLLOW SCHEDULE, HOLD and VACATION selections.
If fixed temperatures are desired, use SCHEDULE button to turn on arrow icon next to HOLD. This will maintain setpoints, not allowing them to change with programmed schedule.