Bryant T6-PRH-A installation instructions Operational Information, Timers

Page 54

OPERATIONAL INFORMATION

Timers

Five-Minute Compressor Timeguard

This timer prevents compressor from starting unless it has been off for at least 5 minutes. It can be overridden for 1 cycle by simultaneously pressing FAN and UP buttons.

Cycle Timer

Based on the selection of 2, 4, or 6 cycles per hour, this timer is set to 30, 15, or 10 minutes. This much time must elapse from the start of one cycle before another cycle can start. It serves to impose the cycles per hour limits. It can be defeated for one cycle by simultaneously pressing the FAN and UP buttons.

Ten-Minute Staging Timer

In multistage heating or cooling, this timer prevents any higher stage from turning on until preceding stage has been on for 10 minutes. When staging between compressor and electric heat or between compressor and furnace heat, the time is configurable. The timer is configurable via Option 17. This timer is overridden if temperature error is greater than 5_ (usually due to a large change in desired temperature) and equipment stages up in 60 second intervals.

Defrost

When defrost occurs in a Hybrid Heat system, the furnace will operate during the defrost cycle. At the end of the defrost cycle, the furnace and heat pump will be de-energized while the fan is energized for 2 minutes allowing the heat exchanger to cool down. At the end of the 2 minute time, the heat pump will be re-energized if a call for heat still exists.

Detection of defrost will not work properly if the installer has configured the O/W2/B output to function as a B output. During heat pump heating, a defrost

54

Image 54
Contents Installation Instructions Table of Contents Safety ConsiderationsIntroduction Installation Considerations PowerModels Humidify Equipment and ConnectionsOutdoor Temperature Sensor Dehumidify Equipment and ConnectionsRemote Indoor Temperature Sensor Two-Piece Thermidistat Control ConfigurationInstallation T6-PRH-A Carton ContentsT6-NRH-A Carton Contents Thermidistat Control LocationInstall Thermidistat Control Unit Damage Hazard Two-Piece Installation Environmental HazardPress Tabs to Remove Backplate Backplate Mounting Control Module Wiring Guide Secure Wires to Terminal Strip Attach Display to Backplate Equipment Control Module on Equipment Standoff Cover on Equipment Control Module Single-Piece Installation Equipment Control Module Reattach Display Module Set Thermidistat Control Configuration Page To Enter Configuration Mode Configuration Options -Selection Option 02 Clean Filter TimerOption 01 Equipment Type Option 06 Cooling Lockout Below 55F/13C Option 03 Fahrenheit/CentigradeOption 04 Fan G On With W/W1 Option 07 ZoningOption 08 Auxiliary Heat Lockout Temperature Option 10 Reversing ValveOption 11 Deadband Setting Between Heat & Cool Option 12 Smart RecoveryOption 13 Room Air Temperature Offset Adjust Option 14 Humidity Display Offset Adjust Option 15 Enable Auto ModeOption 16 Maximum Cycles Per Hour Option 18 Backlight Configuration Option 17 Time Between Equipment StagesPage Option 20 Outdoor Air Temperature Offset Adjustment Option 21 Keypad Lockout programmable models onlyOption 21 Keypad Lockout non-programmable models only Default is of off Page Option 26 Minimum Cooling Setpoint Option 27 Maximum Heating SetpointOption 28 UV Light Reminder Option 29 Humidifier Pad Reminder Option 30 Programmable Fan programmable models onlyPage Option 33 Single or Two-Piece Installation Option 40 Humidify FanOption 41 Variable Speed Blower Option 42 Variable Speed Super Dehumidification Option 43 Intelligent Heat StagingOption 44 Super Comfort Heat Option 99 Reset to Factory Defaults System START-UP and CheckoutTo Test FAN Final Settings Energy Star Default SchedulePage Humidity Control Features HumidificationHumidification Selections To Select Humidification non-programmable DehumidificationTo Select Humidification programmable Additional Humidify CommentsPage Auto Humidity Additional Dehumidify Comments Dehumidify Output and Equipment ConnectionsVacation programmable models only Vacation Humidification Vacation Setpoints Default ValuesVacation Setpoints Vacation DehumidificationTimers Operational InformationEquipment On Indicators Heat/Cool Setpoints Desired TemperatureThree-Minute Minimum on Time Auto Changeover Humidify and Dehumidify IndicatorsEmergency Heat Mode Programmable Fan programmable models onlyTroubleshooting Error CodesPage Equipment Configuration Outputs Cool Heat Wiring Diagrams Display to Equipment Control Module ConnectionFV/FK Fan Coil with 2-Stage Heat Pump Typical Fan Coil with Heat Pump OAT RRS Srtn FV/FK Fan Coil w/2-Stage Air Conditioner Typical Fan Coil with Air Conditioner A08128 FV/FK Fan Coil with 1-Stage Heat Pump Typical Fan Coil Heating Only Thermidistat Control w/Dry Contact Control for Fan Run Time FV/FK Fan Coil with 1-Stage Air Conditioner Typical Fan Coil Cooling Only Variable Speed/Multi-Stage Furnace with 2-Stage Heat Pump Single-Stage Furnace with Heat Pump Hybrid Heat Variable Speed/Multi-Stage Furnace w/2-Stage Air Conditioner Single-Stage Furnace with Air Conditioner Variable Speed/Multi-Stage Furnace w/Single-Stage Heat Pump Single-Stage Furnace Heating Only A08140 Single-stage Furnace with Air Conditioner and Split Power Thermidistat Control Configuration Record Mode SettingsConfiguration Options Configuration Options Catalog No IIT6---PRH---03

T6-PRH-A specifications

The Bryant T6-PRH-A is a cutting-edge thermostat designed for modern heating and cooling systems, making it a popular choice among homeowners seeking efficiency and comfort. This smart thermostat integrates advanced technologies that enhance usability and control over home climate management.

One of the main features of the T6-PRH-A is its Wi-Fi capability, which allows users to control their home heating and cooling systems from anywhere using a smartphone or tablet. The intuitive mobile app is compatible with both iOS and Android devices, enabling real-time adjustments and monitoring of indoor temperatures. This remote access is especially beneficial for those who want to ensure their home is at a comfortable temperature before arriving, thus increasing convenience and comfort.

Another key characteristic of the T6-PRH-A is its compatibility with a variety of heating and cooling systems. It can seamlessly integrate with HVAC systems, heat pumps, and even multi-stage installations. This versatility is crucial for homeowners with unique system requirements, ensuring that the T6-PRH-A can fulfill diverse heating and cooling needs.

The thermostat also features a user-friendly touchscreen interface, which simplifies navigation and temperature adjustments. Users can easily program schedules, set temperature preferences, and review energy usage statistics directly on the device. This promotes energy-efficient practices by allowing homeowners to visualize their consumption and make informed decisions about their heating and cooling habits.

Moreover, the T6-PRH-A supports geofencing technology, which can detect when homeowners are away from the residence. The thermostat automatically adjusts the temperature based on the occupants' location, conserving energy when the home is unoccupied and ensuring a comfortable environment upon return.

Additionally, energy-saving modes such as Smart Recovery help in optimizing comfort without unnecessary energy expenditure. This feature allows the thermostat to learn how long it takes to heat or cool a space, starting the process early to achieve the desired temperature at the specified time while minimizing energy usage.

In summary, the Bryant T6-PRH-A is a sophisticated thermostat equipped with an array of features designed to maximize comfort, efficiency, and control over home climate. Its Wi-Fi connectivity, user-friendly interface, compatibility with various systems, and intelligent energy-saving technologies make it an ideal choice for today’s tech-savvy homeowners.