Bryant T6-PRH-A installation instructions

Page 58

seconds. The control will operate from the temperature sensed by the working sensor.

E1 - If the Display Module and the Equipment Control Module cannot communicate via two-wire connection, an E1 will be displayed.

E2 - There is no E2 error message.

E3 - If Thermidistat Control cannot properly read outdoor temperature, and it is needed for proper operation, display will indicate “--” in the outdoor temperature location. If Option 06, 08, 09, 22, 23 or 44 is not set to OFF, display will indicate “--” in the outdoor temperature location.

E4 - If Thermidistat Control’s internal memory fails, E4 will be displayed. Replace Thermidistat Control.

E5 - If Thermidistat Control cannot properly read humidity, E5 will be displayed. Replace Thermidistat Control. If both Humidify and Dehumidify have been set to OF, the humidity value will be shown as “--” when viewed from the humidity menu, but no E5 will be shown in the display.

Table 4 can be used as a troubleshooting tool for determining which outputs will be active for a particular configuration and each operating mode.

58

Image 58
Contents Installation Instructions Table of Contents Safety ConsiderationsIntroduction Installation Considerations PowerModels Humidify Equipment and ConnectionsOutdoor Temperature Sensor Dehumidify Equipment and ConnectionsRemote Indoor Temperature Sensor Two-Piece Thermidistat Control ConfigurationInstallation T6-PRH-A Carton ContentsT6-NRH-A Carton Contents Thermidistat Control LocationInstall Thermidistat Control Unit Damage Hazard Two-Piece Installation Environmental HazardPress Tabs to Remove Backplate Backplate Mounting Control Module Wiring Guide Secure Wires to Terminal Strip Attach Display to Backplate Equipment Control Module on Equipment Standoff Cover on Equipment Control Module Single-Piece Installation Equipment Control Module Reattach Display Module Set Thermidistat Control Configuration Page To Enter Configuration Mode Option 02 Clean Filter Timer Configuration Options -SelectionOption 01 Equipment Type Option 06 Cooling Lockout Below 55F/13C Option 03 Fahrenheit/CentigradeOption 04 Fan G On With W/W1 Option 07 ZoningOption 08 Auxiliary Heat Lockout Temperature Option 10 Reversing ValveOption 12 Smart Recovery Option 11 Deadband Setting Between Heat & CoolOption 13 Room Air Temperature Offset Adjust Option 15 Enable Auto Mode Option 14 Humidity Display Offset AdjustOption 16 Maximum Cycles Per Hour Option 18 Backlight Configuration Option 17 Time Between Equipment StagesPage Option 21 Keypad Lockout programmable models only Option 20 Outdoor Air Temperature Offset AdjustmentOption 21 Keypad Lockout non-programmable models only Default is of off Page Option 27 Maximum Heating Setpoint Option 26 Minimum Cooling SetpointOption 28 UV Light Reminder Option 29 Humidifier Pad Reminder Option 30 Programmable Fan programmable models onlyPage Option 40 Humidify Fan Option 33 Single or Two-Piece InstallationOption 41 Variable Speed Blower Option 42 Variable Speed Super Dehumidification Option 43 Intelligent Heat StagingOption 44 Super Comfort Heat Option 99 Reset to Factory Defaults System START-UP and CheckoutTo Test FAN Final Settings Energy Star Default SchedulePage Humidification Humidity Control FeaturesHumidification Selections To Select Humidification non-programmable DehumidificationTo Select Humidification programmable Additional Humidify CommentsPage Auto Humidity Additional Dehumidify Comments Dehumidify Output and Equipment ConnectionsVacation programmable models only Vacation Humidification Vacation Setpoints Default ValuesVacation Setpoints Vacation DehumidificationTimers Operational InformationHeat/Cool Setpoints Desired Temperature Equipment On IndicatorsThree-Minute Minimum on Time Auto Changeover Humidify and Dehumidify IndicatorsEmergency Heat Mode Programmable Fan programmable models onlyTroubleshooting Error CodesPage Equipment Configuration Outputs Cool Heat Wiring Diagrams Display to Equipment Control Module ConnectionFV/FK Fan Coil with 2-Stage Heat Pump Typical Fan Coil with Heat Pump OAT RRS Srtn FV/FK Fan Coil w/2-Stage Air Conditioner Typical Fan Coil with Air Conditioner A08128 FV/FK Fan Coil with 1-Stage Heat Pump Typical Fan Coil Heating Only Thermidistat Control w/Dry Contact Control for Fan Run Time FV/FK Fan Coil with 1-Stage Air Conditioner Typical Fan Coil Cooling Only Variable Speed/Multi-Stage Furnace with 2-Stage Heat Pump Single-Stage Furnace with Heat Pump Hybrid Heat Variable Speed/Multi-Stage Furnace w/2-Stage Air Conditioner Single-Stage Furnace with Air Conditioner Variable Speed/Multi-Stage Furnace w/Single-Stage Heat Pump Single-Stage Furnace Heating Only A08140 Single-stage Furnace with Air Conditioner and Split Power Thermidistat Control Configuration Record Mode SettingsConfiguration Options Configuration Options Catalog No IIT6---PRH---03

T6-PRH-A specifications

The Bryant T6-PRH-A is a cutting-edge thermostat designed for modern heating and cooling systems, making it a popular choice among homeowners seeking efficiency and comfort. This smart thermostat integrates advanced technologies that enhance usability and control over home climate management.

One of the main features of the T6-PRH-A is its Wi-Fi capability, which allows users to control their home heating and cooling systems from anywhere using a smartphone or tablet. The intuitive mobile app is compatible with both iOS and Android devices, enabling real-time adjustments and monitoring of indoor temperatures. This remote access is especially beneficial for those who want to ensure their home is at a comfortable temperature before arriving, thus increasing convenience and comfort.

Another key characteristic of the T6-PRH-A is its compatibility with a variety of heating and cooling systems. It can seamlessly integrate with HVAC systems, heat pumps, and even multi-stage installations. This versatility is crucial for homeowners with unique system requirements, ensuring that the T6-PRH-A can fulfill diverse heating and cooling needs.

The thermostat also features a user-friendly touchscreen interface, which simplifies navigation and temperature adjustments. Users can easily program schedules, set temperature preferences, and review energy usage statistics directly on the device. This promotes energy-efficient practices by allowing homeowners to visualize their consumption and make informed decisions about their heating and cooling habits.

Moreover, the T6-PRH-A supports geofencing technology, which can detect when homeowners are away from the residence. The thermostat automatically adjusts the temperature based on the occupants' location, conserving energy when the home is unoccupied and ensuring a comfortable environment upon return.

Additionally, energy-saving modes such as Smart Recovery help in optimizing comfort without unnecessary energy expenditure. This feature allows the thermostat to learn how long it takes to heat or cool a space, starting the process early to achieve the desired temperature at the specified time while minimizing energy usage.

In summary, the Bryant T6-PRH-A is a sophisticated thermostat equipped with an array of features designed to maximize comfort, efficiency, and control over home climate. Its Wi-Fi connectivity, user-friendly interface, compatibility with various systems, and intelligent energy-saving technologies make it an ideal choice for today’s tech-savvy homeowners.