LG Electronics 1003C Residential Standard, Manufactured Mobile Home Standard, Important Notes

Page 12

INSTALLATION

See Pipe Manufacturers Instructions For Installation Requirements Of Venting Components And Vent Clearances.

RESIDENTIAL STANDARD

Using 6” (152 mm) Diameter Single Wall

Connector Pipe. Not Approved For

Manufactured (Mobile) Homes.

Chimney

Termination Cap

Storm

Collar

Roof

Flashing

Ceiling Support

Assembly

Slip Adapter

Chimney

Connector

6” x 24”

24-Gage

Single Wall Pipe

MANUFACTURED (MOBILE) HOME STANDARD

Using 6” (152 mm) Diameter Type L-Vent Connector Pipe

 

Spark Arrestor Cap

3 ft. (915 mm)

 

 

 

 

 

 

Minimum

 

 

 

 

Storm Collar

 

 

 

 

 

 

Flashing

 

 

14.5”

 

 

 

 

 

(369 mm)

 

 

 

 

 

Support Box

Minimum 12-

 

 

15 ft. (366-

 

 

 

 

 

 

 

458 cm) of

 

 

 

 

Flue to

 

 

 

 

Achieve a

 

 

 

 

Stable Draft

 

 

 

 

DVL Close

 

 

 

 

 

 

Clearance

 

 

7 ft. (214 cm)

 

 

 

Connector

 

 

Minimum

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Floor

Protection

Square, Outside

5 ¼” (134 mm)

Air Floor Duct

IMPORTANT NOTES:

Minimize the use of elbows (30°, 45° or 90°) - Offsets in the venting system are very restrictive and will inhibit the draft (i.e. You will lose approximately 5 feet of effective draft for every 90 degrees of direction change). This appliance re- quires 12 to 15 feet of effective draft for optimum perform- ance (see Draft Requirements on page 11).

First section of pipe must be vertical - Use as much straight vertical pipe directly above the appliance as possible be- fore using an elbow (a 2’ to 3’ initial vertical rise is sug- gested).

PAGE 12

Image 12
Contents EPA Certified Catalytic Wood Burning Stove 775003M, Rev. P, 11/03Important Warnings Table of Contents Planning Your Installation Smoke DetectorsSelecting a Location Floor Protection USA RequirementsCanada Requirements Standard Parallel Hearth PAD ShownCombustible Wall Clearances Alcove Clearances Reduced Masonry Structure Clearance AlcoveProtected Wall Clearance Installation AIR Intake CoverOutside AIR Stove Outside Air Floor Duct Floor ProtectorAcceptable Connector Pipe for INSTALLA- Tions Securing the Stove to the FloorGrounding Stove Remove ASH Drawer ClipChimney Inspection Vapor Barrier At Chimney PenetrationChimney Height Requirements 2’ by 10’ Rule for Vent TerminationDraft Test Procedure Draft RequirementsUsing 6 152 mm Diameter Type L-Vent Connector Pipe Residential StandardManufactured Mobile Home Standard Important NotesSides, to maintain the 9 228.6 mm air space. When fastening Method B 228.6 mm Clearance to Combustible Wall MemberWall pass-through with a minimum 9 228.6 mm air space be Inside wall of the Solid-Pak chimney. The inner endCare and OPERATI0N Care and Operation Fuel DoorGlass HOW to Start and Maintain a Fire BREAK-IN PeriodCatalytic Temperature Probe RefuelingBypass Damper Control Burn Recommended FuelMaintenance FuelDoor / Glass Gasket and ASH Drawer GAS- KET Replacing GlassCatalyst Replacement Side Cut-Away View of FireboxTroubleshooting Catalyst Plugging Catalyst DeactivationCatalyst Substrate Cracking Catalyst SubstrateOverfiring Caused From Improper Installation Overfiring DamageOverfiring Caused From Improper Operation Specifications Model 1003C Fire Box Size Cubic feetItem no Description Replacement Parts List Model 1003C Damper Assembly Catalytic Combustor System ComponentsOutside Air Floor Duct OAFD-S Stove-Stat Kit SSKBlower Kit BK-100 Variable Speed Control, Dial-A-TempSAFETY/LISTING Label EPA Label Service and Maintenance LOG Ownership RecordsWest Taft Avenue Orange, CA