LG Electronics 1003C Alcove Clearances, Reduced Masonry Structure Clearance Alcove

Page 7

PLANNING YOUR INSTALLATION

ALCOVE CLEARANCES

NOTE:" = inches, mm = millimeter, cm = centimeter Alcoves must have minimum dimensions of 84" (214 cm) height, 56" (142 cm) width and 24" (610 mm) maximum depth.

Require pipe: Type L Vent pipe to the top of the stove. Manufactured (mobile) home installations must be equipped with a rain cap and spark arrestor and must use a pipe shield extending a minimum of 24" (610 mm) above the stove (resting on stove) is mandatory for the installation of this appliance into a combustible alcove.

Alcove Dimension Requirements

24” (610 mm)

Depth

Maximum

56” (143 cm) Minimum

84”

(214 cm)

Min.

Alcove Top View / Stove Clearances

ALCOVE CLEARANCES:

Back wall to pipe O.D.

11" / 280 mm

Side wall to pipe O.D.

25.5" / 648 mm

Back wall to stove

5.5" / 140 mm

Side wall to stove

16" / 407 mm

Alcove - Top View

11” (280 mm)

5.5” (140 mm)

16”

25.5”

(407 mm)

(648 mm)

*NOTE: Alcove dimensions cannot be reduced by the use of non-combustible materials such as brick, stone, etc. Alcove dimensions listed are minimum dimensions and are not measurements for building an Alcove. You will need to consider these clearances, as well as other dimensional requirements before you build the alcove and install this appliance.

REDUCED MASONRY STRUCTURE CLEARANCE (ALCOVE)

Your stove can be installed in a masonry structure with reduced clearances if the structure was built to National Building Code for fireplaces and chimneys (UBC 37).

The firebox of the masonry structure must be of ade- quate size to allow a minimum of 6” (152.4 mm) clear- ance to the sides and top of the stove and 2” (50.8 mm) clearance to the rear. All stove models must be installed on their original listed legs or base unless otherwise specified by OMNI Testing Laboratory.

The minimum venting requirement is a listed chimney liner that extends from the flue collar of the stove to the first tile liner of the chimney where it is sealed. All joints and connections must be made airtight to prevent leak- ing and downdrafts.

PROTECTED WALL CLEARANCE

Some local codes will allow reduced clearances when the stove is installed adjacent to a protected wall system. Your local building official must approve the variance. Normally, the protected wall system is defined as a non- combustible material with a minimum of 1” (25.4 mm) air space behind. Check your local building codes or with a qualified installer (Ref. NFPA 211).

PAGE 7

Image 7
Contents 775003M, Rev. P, 11/03 EPA Certified Catalytic Wood Burning StoveImportant Warnings Table of Contents Smoke Detectors Planning Your InstallationSelecting a Location Standard Parallel Hearth PAD Shown Floor ProtectionUSA Requirements Canada RequirementsCombustible Wall Clearances Reduced Masonry Structure Clearance Alcove Alcove ClearancesProtected Wall Clearance Stove Outside Air Floor Duct Floor Protector InstallationAIR Intake Cover Outside AIRRemove ASH Drawer Clip Acceptable Connector Pipe for INSTALLA- TionsSecuring the Stove to the Floor Grounding Stove2’ by 10’ Rule for Vent Termination Chimney InspectionVapor Barrier At Chimney Penetration Chimney Height RequirementsDraft Requirements Draft Test ProcedureImportant Notes Using 6 152 mm Diameter Type L-Vent Connector PipeResidential Standard Manufactured Mobile Home StandardInside wall of the Solid-Pak chimney. The inner end Sides, to maintain the 9 228.6 mm air space. When fasteningMethod B 228.6 mm Clearance to Combustible Wall Member Wall pass-through with a minimum 9 228.6 mm air space beCare and OPERATI0N Fuel Door Care and OperationGlass BREAK-IN Period HOW to Start and Maintain a FireBurn Recommended Fuel Catalytic Temperature ProbeRefueling Bypass Damper ControlFuel MaintenanceReplacing Glass Door / Glass Gasket and ASH Drawer GAS- KETSide Cut-Away View of Firebox Catalyst ReplacementTroubleshooting Catalyst Substrate Catalyst PluggingCatalyst Deactivation Catalyst Substrate CrackingOverfiring Damage Overfiring Caused From Improper InstallationOverfiring Caused From Improper Operation Fire Box Size Cubic feet Specifications Model 1003CItem no Description Replacement Parts List Model 1003C Catalytic Combustor System Components Damper AssemblyVariable Speed Control, Dial-A-Temp Outside Air Floor Duct OAFD-SStove-Stat Kit SSK Blower Kit BK-100SAFETY/LISTING Label EPA Label Ownership Records Service and Maintenance LOGWest Taft Avenue Orange, CA