LG Electronics 1003C Outside Air Floor Duct OAFD-S, Stove-Stat Kit SSK, Blower Kit BK-100

Page 28

OPTIONAL ACCESSORIES - Model 1003C

Note: Install and use accessories per instructions provided with the accessory kit.

Catalog #

Model

Description

 

 

 

14M67

OAFD-S

Outside Air Floor Duct

* 14M72

DK100-G

Gold Door Kit

* H0533

DK100-B

Black Door Kit

14M22

BK-100

Blower Kit

14M21

SSK

Stove Stat Kit

70K99

TSPK-B

Touch-up Spray Paint Kit, Black (12 oz

 

 

spray can)

Outside Air Floor Duct (OAFD-S)

Outside air can be delivered for combustion air by utilizing this floor penetration duct.

(Duct penetration measures 5 ¼” square)

Stove

Floor

Duct

Stove-Stat Kit (SSK)

To automate the blower system an additional Stove-Stat kit can be purchased. The Stove-Stat is a heat sensor switch that will automatically turn on the blower when the stove is hot and automatically turn it off when the stove is cool.

Stove-Stat

Magnetic Head

Floor Protector

Blower Assembly

Blower Power

Cord Plug

Stove-Stat Power

Cord Plug

Grounded 110 Volt

Wall Receptacle

Blower Kit (BK-100)

A Blower Kit (includes rheostat for variable speed control) is available for increased heat circulation.

Stove Rear Heat

Shield

160 CFM Blower

Assembly

2 Screws

10-24 x 1/2

Variable Speed Control, Dial-A-Temp

Plug Dial-A-Temp into Wall Outlet

Plug Power Cord into Bottom of Dial-A-Temp

PAGE 28

Image 28
Contents EPA Certified Catalytic Wood Burning Stove 775003M, Rev. P, 11/03Important Warnings Table of Contents Smoke Detectors Planning Your InstallationSelecting a Location Floor Protection USA RequirementsCanada Requirements Standard Parallel Hearth PAD ShownCombustible Wall Clearances Reduced Masonry Structure Clearance Alcove Alcove ClearancesProtected Wall Clearance Installation AIR Intake CoverOutside AIR Stove Outside Air Floor Duct Floor ProtectorAcceptable Connector Pipe for INSTALLA- Tions Securing the Stove to the FloorGrounding Stove Remove ASH Drawer ClipChimney Inspection Vapor Barrier At Chimney PenetrationChimney Height Requirements 2’ by 10’ Rule for Vent TerminationDraft Test Procedure Draft RequirementsUsing 6 152 mm Diameter Type L-Vent Connector Pipe Residential StandardManufactured Mobile Home Standard Important NotesSides, to maintain the 9 228.6 mm air space. When fastening Method B 228.6 mm Clearance to Combustible Wall MemberWall pass-through with a minimum 9 228.6 mm air space be Inside wall of the Solid-Pak chimney. The inner endCare and OPERATI0N Fuel Door Care and OperationGlass HOW to Start and Maintain a Fire BREAK-IN PeriodCatalytic Temperature Probe RefuelingBypass Damper Control Burn Recommended FuelMaintenance FuelDoor / Glass Gasket and ASH Drawer GAS- KET Replacing GlassCatalyst Replacement Side Cut-Away View of FireboxTroubleshooting Catalyst Plugging Catalyst DeactivationCatalyst Substrate Cracking Catalyst SubstrateOverfiring Damage Overfiring Caused From Improper InstallationOverfiring Caused From Improper Operation Specifications Model 1003C Fire Box Size Cubic feetItem no Description Replacement Parts List Model 1003C Damper Assembly Catalytic Combustor System ComponentsOutside Air Floor Duct OAFD-S Stove-Stat Kit SSKBlower Kit BK-100 Variable Speed Control, Dial-A-TempSAFETY/LISTING Label EPA Label Service and Maintenance LOG Ownership RecordsWest Taft Avenue Orange, CA