LG Electronics operation manual Replacement Parts List Model 1003C

Page 26

REPLACEMENT PARTS LIST: Model 1003C

Cat. No.

Model

Description

 

 

 

 

/ Part No.

 

Firebrick -

All firebrick are 1 ¼” thick (see firebrick diagram below)

FB-1

 

Firebrick, 9 x 4

½” Regular (order 5, if set is needed)

FB-2

 

Firebrick, 9 x 4

½” W/Notch (order 8, if set is needed)

FB12

 

Firebrick, 7 3/8 x 4

½ x 6

¾” Left (requires 1)

FB13

 

Firebrick, 7

3/8 x 4

½ x 6

¾” Right (requires 1)

FB14

 

Firebrick, 6

3/4 x 3 x 2

3/8” Left (requires 1)

FB15

 

Firebrick, 6

3/4 x 3 x 2

3/8” Right (requires 1)

1115

 

Grate, Cast Iron

 

 

 

Firebrick

Left

Bottom

Right

Back

For the location of the nearest Dealer for replacement parts, contact: Lennox Hearth Products 1110 West Taft Avenue Orange, CA 92865

PAGE 26

Image 26
Contents EPA Certified Catalytic Wood Burning Stove 775003M, Rev. P, 11/03Important Warnings Table of Contents Selecting a Location Planning Your InstallationSmoke Detectors Canada Requirements Floor ProtectionUSA Requirements Standard Parallel Hearth PAD ShownCombustible Wall Clearances Protected Wall Clearance Alcove ClearancesReduced Masonry Structure Clearance Alcove Outside AIR InstallationAIR Intake Cover Stove Outside Air Floor Duct Floor ProtectorGrounding Stove Acceptable Connector Pipe for INSTALLA- TionsSecuring the Stove to the Floor Remove ASH Drawer ClipChimney Height Requirements Chimney InspectionVapor Barrier At Chimney Penetration 2’ by 10’ Rule for Vent TerminationDraft Test Procedure Draft RequirementsManufactured Mobile Home Standard Using 6 152 mm Diameter Type L-Vent Connector PipeResidential Standard Important NotesWall pass-through with a minimum 9 228.6 mm air space be Sides, to maintain the 9 228.6 mm air space. When fasteningMethod B 228.6 mm Clearance to Combustible Wall Member Inside wall of the Solid-Pak chimney. The inner endCare and OPERATI0N Glass Care and OperationFuel Door HOW to Start and Maintain a Fire BREAK-IN PeriodBypass Damper Control Catalytic Temperature ProbeRefueling Burn Recommended FuelMaintenance FuelDoor / Glass Gasket and ASH Drawer GAS- KET Replacing GlassCatalyst Replacement Side Cut-Away View of FireboxTroubleshooting Catalyst Substrate Cracking Catalyst PluggingCatalyst Deactivation Catalyst SubstrateOverfiring Caused From Improper Operation Overfiring Caused From Improper InstallationOverfiring Damage Specifications Model 1003C Fire Box Size Cubic feetItem no Description Replacement Parts List Model 1003C Damper Assembly Catalytic Combustor System ComponentsBlower Kit BK-100 Outside Air Floor Duct OAFD-SStove-Stat Kit SSK Variable Speed Control, Dial-A-TempSAFETY/LISTING Label EPA Label Service and Maintenance LOG Ownership RecordsWest Taft Avenue Orange, CA