TROUBLESHOOTING

CATALYST PLUGGING

1.Burning materials that produce a lot of char and fly ash. Do not burn materials such as garbage, gift wrap, cardboard, etc.

2.Burning wet pitchy woods or burning large loads of small diameter wood with the combustor in the op- eration position (without light-off taking place). Burn proper fuel only. Do not close bypass until tempera- tures are high enough to initiate light off.

CATALYST DEACTIVATION

1.Burning large quantities of trash, pressure-treated lumber or painted woods, etc. will deactivate the catalyst. Burn proper fuels only. See Catalyst Re- placement, page 20.

CATALYST SUBSTRATE CRACKING

1.Normal operation, as long as combustor remains intact. If cracking causes large pieces to fall out, re- place combustor.

2.Mishandling or abuse. Handle with care.

3.Excessive draft. Correct installation. See Draft Re- quirements, page 11.

CATALYST SUBSTRATE

1.Extreme thermal shock. Combustor is being worked too hard.

2.Excessive draft. Correct installation. See Draft Re- quirements, page 11.

CATALYST PEELING

Extreme Temperatures (over-firing) at combustor sur- face can cause the catalyst to peel. Some minor peeling does not affect function. Severe peeling would close cell openings and cause a plugging problem. If peeling is severe, replace combustor. Do not overfire appliance. See Overfiring, on page 23.

TAR AND LIQUID CREOSOTE LEAKING FROM METAL FLUE JOINTS

1. No chimney cap on chimney. Install cap.

2.Metal flue assembled improperly. Top flue sections should be inserted into lower flue sections.

DENSE SMOKE LEAVING CHIMNEY

1.Water vapor (on cold still days water vapor may be mistaken for smoke). Water vapor is normal and should be of little concern.

2.Wet, pitchy woods being burned. Burn dry sea- soned wood only.

3.Bypass in open position. Close bypass.

4.Combustor not functioning. See Catalyst Replace- ment, page 20.

NOISY HEAT SHIELD (OIL CANNING)

Rear or side heat shields make a noise (bong) during heat up or cool down.

Large pieces of metal such as a side or rear heat shield on a stove will normally expand and retract as it heats and cools. If a noise develops in these shields (i.e. as component heats and expands, it may flex, resulting in a “bong” sound) it can be corrected. See following pro- cedures:

There is an adjustable tension bolt in the center of the rear heat shield. To eliminate the expansion noise during stove use, adjust the bolt and nut to increase tension on the shield.

Tension

Bolt

PAGE 22

Image 22
Contents EPA Certified Catalytic Wood Burning Stove 775003M, Rev. P, 11/03Important Warnings Table of Contents Smoke Detectors Planning Your InstallationSelecting a Location Canada Requirements Floor ProtectionUSA Requirements Standard Parallel Hearth PAD ShownCombustible Wall Clearances Reduced Masonry Structure Clearance Alcove Alcove ClearancesProtected Wall Clearance Outside AIR InstallationAIR Intake Cover Stove Outside Air Floor Duct Floor ProtectorGrounding Stove Acceptable Connector Pipe for INSTALLA- TionsSecuring the Stove to the Floor Remove ASH Drawer ClipChimney Height Requirements Chimney InspectionVapor Barrier At Chimney Penetration 2’ by 10’ Rule for Vent TerminationDraft Test Procedure Draft RequirementsManufactured Mobile Home Standard Using 6 152 mm Diameter Type L-Vent Connector PipeResidential Standard Important NotesWall pass-through with a minimum 9 228.6 mm air space be Sides, to maintain the 9 228.6 mm air space. When fasteningMethod B 228.6 mm Clearance to Combustible Wall Member Inside wall of the Solid-Pak chimney. The inner endCare and OPERATI0N Fuel Door Care and OperationGlass HOW to Start and Maintain a Fire BREAK-IN PeriodBypass Damper Control Catalytic Temperature ProbeRefueling Burn Recommended FuelMaintenance FuelDoor / Glass Gasket and ASH Drawer GAS- KET Replacing GlassCatalyst Replacement Side Cut-Away View of FireboxTroubleshooting Catalyst Substrate Cracking Catalyst PluggingCatalyst Deactivation Catalyst SubstrateOverfiring Damage Overfiring Caused From Improper InstallationOverfiring Caused From Improper Operation Specifications Model 1003C Fire Box Size Cubic feetItem no Description Replacement Parts List Model 1003C Damper Assembly Catalytic Combustor System ComponentsBlower Kit BK-100 Outside Air Floor Duct OAFD-SStove-Stat Kit SSK Variable Speed Control, Dial-A-TempSAFETY/LISTING Label EPA Label Service and Maintenance LOG Ownership RecordsWest Taft Avenue Orange, CA