4.Secure the grille to the sleeve by tightening the four screws to their corresponding holes in the grille.
5.Remove the wire handle after the installation is complete.
Note:
The stamped aluminum grille includes 6 screws, washers, nuts, and plastic grommets. The architectural grille includes 4 screws.
Condensate Drain kit
Part No: AYDR101
Receiving
Upon receipt of the product, inspect the shipping carton for signs of visible damage. Report any damage or shortage to the carrier and note it on the delivery receipt. The product must be stored in its original shipping carton in a dry, secure place prior to its installation and use.
Installation
The installation and servicing of the equipment referred to in this booklet should be performed by qualified, experienced technicians.
Figure 41 – Components of Drain Kits
Description
Condensate water will drain from the chassis into the sleeve during normal heat pump operation. This can also occur during times of high humidity when in cooling operation. Install either the outdoor or indoor drain kit components to control the condensate water where normal drainage from the wall sleeve is not possible or undesirable. See Figure 35 for all components of the drain kit.
WARNING
Hazardous Voltage!
Disconnect all electric power, including remote disconnects before servicing. Follow proper lockout/ tagout procedures to ensure the power can not be inadvertently energized. Failure to disconnect power before servicing could result in death or serious injury.
Important Note:
The unit OFF switch does not disconnect all electrical power to this unit.
DRAIN FITTING |
|
| ||
PLATE B |
| PLATE C |
| PLATE C |
GASKETS A
1/2" DRAIN FITTING
|
|
| MTG. SCREWS |
|
| ||
|
|
|
|
|
| ||
MTG. SCREWS |
|
|
|
|
| ||
| GASKET E FOR | ||||||
|
| PLATE D |
| PLATE D |
|
Drain Installation
Note:
The optional drain kit serves only as a link between the unit and
Installing the kit without connecting it to a drainage system will result in inadequate condensate removal, possible leakage and corrosion.
Algaecide: Some algaecide products may cause damage to the unit basepan and therefore should not be used. Contact your sales representative when considering the use of a commercial algaecide. See Figure 41 for components of the drain kit.