1.2 FEATURES AND BENEFITS

The PTAC has many features, some of which are different than those found on conventional PTAC units. The servicer must be familiar with these features in order to properly service the unit.

THE SLEEVE AND THE REAR GRILLE

(Available as an option)

VERTICAL AIR DEFLECTOR

SLEEVE ASSEMBLY

REAR GRILLE

(Horizontal Louver)

(Including Aluminum Rear Grille)

(Aluminum Rear Grille)

AIR FILTER

INLET GRILLE (Air Intake)

EXPANDED METAL GRILLE (Superior for a performance)

IIR (Infinite Impulse Response)

The IIR function senses the temperature several times per second and makes micro-adjustments several times per

Compressor Restart Delay

This feature extends the overall life of compressor by preventing the short-cycling of the air-conditioner. When the compressor restarts, LG PTAC is designed to give a minimum of three minutes to have a time of equalizing the refrigerant pressures for optimizing cycling.

Fan-Only Setting - High/Low

The fan can run at HIGH or LOW speed without COOLING or HEATING to provide air circulation and ventilation.

Indoor Fan Speed Selections - High/Low

The fan can run at HIGH or LOW speed for either COOLING or HEATING.

Two Fan motors

The unit has two fan motors to provide quiet operation and maximum efficiency.

LED Diagnostics

All units have this feature indicating the problem when the unit is not operating properly with easy-to-read diagnostics. For example, 1 blink every 2 seconds indicates compressor failure.

Copyright ©2008 LG Electronics. Inc. All right reserved.

- 3 -

Only for training and service purposes

LGE Internal Use Only

 

Image 3
Contents SVC Manual Model LP121CEM-Y8 SpecificationSleeve and the Rear Grille Features and BenefitsQuick Heater Recovery Door Switch/Occupancy SensorOutdoor Air Temperature Switchover Temperature limitsCooling only Model Control LocationsOperation Electric Heating Model VentilationAdditional Controls Temperature LimitingAdditional Controls Removing the Front GrilleRemote Wall Thermostat REMOTE/LOCAL ControlEnergy Saver Front Desk ControlDisassembly Instructions Mechanical PartsFront Grille Control BOX Electric Heater Electric Heater Model only AIR Handling PartsAxial FAN Cross Flow FANCompressor Electrical PartsShroud Outdoor Motor6 P.C.B Power CordCapillary Tube Refrigeration CycleCondenser EvaporatorLGE Internal Use Only Pulling Vacuum Dimension of sleeve assembly optional InstallationHOW to Install the Unit Dimension of air conditionerWall Sleeve Installation Wall Case Installation DataGeneral Installation of Wall Case in Wall Opening Preparation of the Front GrillePreparation of the Wall Case for All Types of Construction LGE Internal Use Only Sub-Base Connected Unit Installation 208, 230, and 208/230 Volt Units Electrical SafetyElectrical Requirements Electrical Data for 230/208V ModelDescription Field Installed AccessoriesInstallation Control Panel Key LockHazardous Voltage Condensate Disposal Pump Kit InstallationPlace the top cover assembly back into the unit Spraying Architectural Grille Architecture Grille Aluminum Single PackCondensate Drain kit Drain InstallationOutdoor Drain Kit Installation Outdoor Drain Kit InstallationIndoor Drain Kit Installation ChecklistLeveling Legs Leveling Leg Assembly Installation on Wall Sleeve Leveling Leg AssemblyHard Wire Kit Junction Box Kit Installation and Wiring ProcedureUse Copper Conductors Only Volt Units 208/230 Volt UnitsStandard Escutcheon Remote Escutcheon KitSubbase Part/Location Identification Troubleshooting Guide Outside DimensionsPiping System Troubleshooting Guide Fails to Start Complaint Cause Remedy 208/230V 187V 253V Room AIR Conditioner Voltage LimitsComplaint Cause Remedy CN-IDPT Piping DiagramsPart A, there are 3 types Schematic Diagram435300B Exploded ViewEnlarged picture Condenser Outdoor Service Replacement ProcedureFebruary