LG Electronics LP121CEM-Y8 manual Exploded View, 435300B

Page 46

8. ExplodedView

C

552114

35211A

552113

 

 

 

 

 

 

352115B

 

 

 

 

 

 

352116

 

352390

 

 

 

 

 

 

 

 

 

 

 

 

 

352115

 

 

 

 

 

 

 

 

152302A

 

 

 

 

 

 

135500B

 

 

 

 

 

 

D

342800

 

 

148000

 

 

 

 

 

 

 

 

 

149400

 

 

349600A

 

435300A

 

 

 

 

 

 

 

 

 

 

 

 

435300B

 

 

 

 

 

346810

 

 

 

 

359011

 

 

 

 

 

 

 

 

 

554030

 

 

 

 

 

 

 

 

337000

 

 

 

 

 

 

135515

 

 

546810

 

 

 

 

 

349600B

 

 

 

 

F

 

 

 

 

 

 

 

 

 

 

354210

 

559011

 

 

 

 

 

 

 

549990

 

 

 

 

 

 

 

 

 

 

W50400

 

 

 

 

 

 

 

263230B

 

 

 

130411

 

 

 

 

 

 

 

 

 

 

263230A

 

135500A

 

 

 

 

 

 

 

 

 

 

753010

 

 

 

 

 

 

 

 

 

135312

 

 

249951

 

E

 

 

330870

 

 

 

 

152302B

435301

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A

 

268711B

B

 

 

 

 

238310

 

 

 

 

 

 

149410

 

 

 

 

 

 

135800

 

 

135511

 

 

 

 

 

 

 

 

 

 

 

 

 

 

567502

 

 

 

237200

 

W0CZZB

 

554160

 

 

 

 

 

 

 

 

 

 

 

249941A

 

 

 

 

 

264110

 

261702

 

 

 

 

 

 

 

 

135301

 

 

 

W6640

 

 

 

 

 

 

 

550140

 

 

 

249941B

W0CZZA

147901

 

 

 

 

263230A

Thermistor for Indoor Air Temperature

Housing color : blue

 

 

 

263230B

Thermistor for Evaporator Pipe Temperature

Housing color : white

 

 

 

Note)* Please ensure GCSC since the replacement parts may be changed depending upon the buyer's request. Please check the correct parts in View RPL(Replacement Part List) on GCSC.

(GCSC Website http://biz.lgservice.com)

Copyright ©2008 LG Electronics. Inc. All right reserved.

- 46 -

Only for training and service purposes

LGE Internal Use Only

 

Image 46
Contents SVC Manual Specification Model LP121CEM-Y8Features and Benefits Sleeve and the Rear GrilleTemperature limits Door Switch/Occupancy SensorOutdoor Air Temperature Switchover Quick Heater RecoveryVentilation Control LocationsOperation Electric Heating Model Cooling only ModelRemoving the Front Grille Temperature LimitingAdditional Controls Additional ControlsFront Desk Control REMOTE/LOCAL ControlEnergy Saver Remote Wall ThermostatMechanical Parts Disassembly InstructionsFront Grille Control BOX AIR Handling Parts Electric Heater Electric Heater Model onlyCross Flow FAN Axial FANOutdoor Motor Electrical PartsShroud CompressorPower Cord 6 P.C.BEvaporator Refrigeration CycleCondenser Capillary TubeLGE Internal Use Only Pulling Vacuum Dimension of air conditioner InstallationHOW to Install the Unit Dimension of sleeve assembly optionalWall Case Installation Data Wall Sleeve InstallationGeneral Preparation of the Front Grille Installation of Wall Case in Wall OpeningPreparation of the Wall Case for All Types of Construction LGE Internal Use Only Sub-Base Connected Unit Installation Electrical Data for 230/208V Model Electrical SafetyElectrical Requirements 208, 230, and 208/230 Volt UnitsControl Panel Key Lock Field Installed AccessoriesInstallation DescriptionCondensate Disposal Pump Kit Installation Hazardous VoltagePlace the top cover assembly back into the unit Spraying Architecture Grille Aluminum Single Pack Architectural GrilleDrain Installation Condensate Drain kitOutdoor Drain Kit Installation Outdoor Drain Kit InstallationChecklist Indoor Drain Kit InstallationLeveling Legs Leveling Leg Assembly Leveling Leg Assembly Installation on Wall SleeveJunction Box Kit Installation and Wiring Procedure Hard Wire KitUse Copper Conductors Only 208/230 Volt Units Volt UnitsRemote Escutcheon Kit Standard EscutcheonSubbase Part/Location Identification Outside Dimensions Troubleshooting GuidePiping System Troubleshooting Guide Fails to Start Complaint Cause Remedy Room AIR Conditioner Voltage Limits 208/230V 187V 253VComplaint Cause Remedy Piping Diagrams CN-IDPTSchematic Diagram Part A, there are 3 typesExploded View 435300BCondenser Outdoor Service Replacement Procedure Enlarged pictureFebruary