LG Electronics MFL39817303 Connect the wires to the terminals on, With the screw

Page 21

 

 

Installation

Outdoor

 

 

1. Remove the cover control from the unit by

 

 

loosening the screw.

Outdoor unit

 

Connect the wires to the terminals on the

 

Terminal block

 

control board individually as the following.

 

2. Secure the cable onto the control board with

 

 

the holder (clamper).

Over 5mm

 

3. Refix the cover control to the original position

(0.2")

Conduit panel

Power supply

 

with the screw.

 

cord

Connecting

Wiring Diagram

 

 

cable

BR BL BR BL RD

Cover control

 

 

 

ENGLISH

NOTICE

1.Separately wire power supply cord and connecting cable.

2.Use heat-proof electrical wiring capable of withstanding temperature up to 75°C(167°F).

3.Use outdoor and waterproof connection cable rated more than 300V for the connection between indoor and outdoor unit. (For example, Type SJO-WA)

Be sure to comply with local codes while running the wire from the indoor unit to the outdoor unit(size of wire and wiring method, etc).

Every wire must be connected firmly.

No wire should be allowed to touch refrigerant tubing, the compressor or any moving parts.

Installation Manual 21

Image 21
Contents Room Air Conditioner Table of Contents Installation Instructions No installation may cause a fire and electrical shock Be sure not to do Be sure to follow the instructionIt may cause injury or an accident Operation Otherwise, it may cause dispute with the neighbors Otherwise, it may cause water leakageOtherwise, it may cause vibration or water leakage Otherwise, it may do harm to your healthFeatures Symbols used in this ManualInstallation Parts Installation ToolsRead carefully, and then follow step by step Installation Map Select the best Location Indoor unitOutdoor unit Piping Length and Elevation Fixing Installation Plate Drill a Hole in the WallType Cutting Tubes Flaring WorkBurrs removal Putting nut onCheck Connecting the PipingIndoor Foamed polyethylene or equivalent is recommendedLbf .ft Indoor unit installationFor left rear piping Piping for passage through piping hole Bad case Good caseHow to use the front panel Connecting the CablesOutdoor Move the link upward and close the front panelFront panel removing Connect the wires to the terminals on Refix the cover control to the original positionWith the screw How to connect wiring to the terminals For strand wiringConnecting cable To check the drainage Checking the DrainageDrain piping Pour a glass of water on the evaporatorForming the Piping Air Purging Air purgingAir purging with vacuum pump Evacuation Soap water methodFinishing the job If bubbles come out, the pipes have leakageTest Running Prepare remote controllerSettlement of outdoor unit Evaluation of the performancePump Down Pump Down ProcedureSelecting the locationOutdoor Unit Installation guide at the seasideMemo Room Air Conditioner No. MFL39817303