Graco TI15605a, TI15596a important safety instructions Troubleshooting, Problem Cause Solution

Page 15

 

 

Troubleshooting

Troubleshooting

 

 

 

 

 

Problem

Cause

Solution

 

 

 

Pump output low on both strokes.

Restricted air supply lines.

Clear any obstructions; be sure all shutoff

 

 

valves are open; increase pressure, but

 

 

do not exceed maximum working pres-

 

 

sure.

 

 

 

 

Exhausted fluid supply.

Refill and reprime pump.

 

 

 

 

Clogged fluid outlet line, valves, etc.

Clear.

 

 

 

 

Worn piston packing.

Replace. See lower manual.

 

 

 

Pump output low on only one stroke.

Held open or worn ball check valves.

Check and repair.

 

 

 

 

Worn piston packings.

Replace. See lower manual.

 

 

 

No output.

Improperly installed ball check valves.

Check and repair.

 

 

 

Pump operates erratically.

Exhausted fluid supply.

Refill and reprime pump.

 

 

 

 

Held open or worn ball check valves.

Check and repair.

 

 

 

 

Worn piston packing.

Replace. See lower manual.

 

 

 

Pump will not operate.

Restricted air supply lines.

Clear any obstructions; be sure all shut

 

 

off valves are open; increase pressure,

 

 

but do not exceed maximum working

 

 

pressure.

 

 

 

 

Exhausted fluid supply.

Refill and reprime pump.

 

 

 

 

Clogged fluid outlet line, valves, etc.

Clear.

 

 

 

 

Damaged air motor.

See air motor manual.

 

 

 

 

Fluid dried on piston rod.

Disassemble and clean pump. See lower

 

 

manual. In future, stop pump at bottom of

 

 

stroke.

 

 

 

3A0538F

15

Image 15
Contents High-Flo4-Ball Pumps Contents Models Related ManualsPart No. Description Fire and Explosion Hazard Personal Protective Equipment Installation GroundingFluid supply container follow local code Flush Before Using Equipment Stand Mount PlumbingWall Mount Fluid shutoff valve D shuts off fluid flow AccessoriesAir Line Fluid LineKey IG . Typical Installation for 1000, 1500, and 2000cc PumpsIG . Typical Installation for 3000 and 4000cc Pumps Key Stop the Pump at the Bottom of Its Stroke Pressure Relief ProcedureOperation Prime the Pump Maintenance Cutaway of TSL Reservoir, and Fill Lines Changing the TSLMaintenance Problem Cause Solution TroubleshootingShield Reassembly DisassemblyReassembly Shield DisassemblyCoupler Torque Values Reassemble the CouplingAdapter and Tie Rods to MotorRatio, 2000cc Pumps PartsHigh-Flo Pumps with 1000cc, 1500cc, or 2000cc 4-Ball Lowers Common PartsRatio, 1000cc Pumps Ratio, 1500cc PumpsHigh-Flo Pumps with 3000cc or 4000 cc 4-Ball Lowers Ratio, 3000cc Pumps Ratio, 4000cc PumpsModel Motor DimensionsWeight ApproxNXT Model Motor Mounting Hole DiagramsMounting Stand Hole Layouts Wall Mount Bracket Technical Data NXT 2200 Air Motor, 2000cc Lower JX20XX Performance ChartsFluid Outlet Pressure Black Curves Air Consumption Gray CurvesFluid Flow in GPM LPM AIR Flow NXT 6500 Air Motor, 4000cc Lower JX33XX NXT 6500 Air Motor, 3000cc Lower JX44XXGraco Information Graco Standard Warranty