ITT IM213 manual Setting the Pressure, Motor Rotation Direction, System Status

Page 18

Starting the System

Section 7 (continued)

Setting the Pressure

When power is applied the pump will start and the system pressure will increase to the factory preset pressure (50 PSI if SP1 is enabled and a 300 PSI sensor is used or 75PSI if SP2 is enabled and a 300 PSI sensor is used). After the pressure has stabilized, use the increase (INC) or decrease (DEC) pressure adjust pushbuttons to adjust the pressure setting. Push and Hold the increase or decrease pushbutton until the desired pressure setting is reached. The new pressure setting will save when the system goes into standby mode (solid green light/pump off). Pressure set point 1 will be adjusted and stored when the SP2/SP1 switch input is open. Pressure set point 1 is preset to 50 PSI when used with a 300 PSI transducer. Pressure set point 2 will be adjusted and stored when the SP2/SP1 switch input is closed. Pressure set point 2 is preset to 75 PSI when used with a 300 PSI transducer.

Motor Rotation Direction

If the pressure/flow seems low or the system is indicating Motor Overload error check the motor rotation direction. Turn the breaker/disconnect switch to the off position and wait 5 minutes. Switch any two leads on the controller output (T1/U, T2/V or T3/W). Turn the breaker/disconnect switch to the on position. Observe pressure and flow. If the pressure or flow still seems low check plumbing.

For CentriPro Motors, connecting T1/U to Red, T2/V to Black and T3/W to Yellow will give the correct rotation.

Note

It is possible for the pump to maintain constant pressure with a low flow or a high suction head even if the pump is rotating backwards. While the pump is running use an amp probe on one of the output power leads connected to the motor and compare the current draw between the two rotation directions. The lowest current reading indicates the pump is running in the correct direction.

System Status

The status indicator light displays the status of the controller. A constant green status code indicates that the pump is in standby mode (pump not running). A blinking green status code indicates that the pump is running. A constant orange light indicates the input voltage is low. A blinking or constant red light indicates a problem with the controller or system. Refer to the access cover side panel for a list of status codes. See Section 9 for more details.

Danger

DANGER

Hazardous voltage

The status code indicator light is not a voltage indicator! Always turn off disconnect switch and circuit breaker and wait 5 minutes before servicing.

18

Image 18
Contents ITT IM213 Commercial WaterIndex Safety Instructions DeathHP = System ComponentsController Product Code Information Volt =System Design Fusible DisconnectDiagram #2 shows a set-up for municipal water connection SectionGeneral Installing the Pressure SensorPiping Pressure Tank, Pressure Relief Valve and Discharge PipingMounting the Controller Power Supply and Wiring Power SupplyDelta/Wye with grounded Wye neutral Delta/Delta with grounded leg Ungrounded secondaryResistance grounding and ground fault protection Open Delta consult factoryFor Frame Size 1 Controllers Single Phase Connection 208/230460 Conduit, Wire and Fuse Sizing 20ºC 30ºC 40ºC 50ºCInput Power and Line Transformer Requirements Output Power ConnectionsStarting the System Input Power Connections Setting the Motor Overload Switches Chart below shows the motor overload setting for each modelSetting the Minimum Frequency Switch Setting the Acceleration/Deceleration SwitchesSetting the No Water Restart Time Switches Setting the Carrier Frequency SwitchSetting the Pressure Motor Rotation DirectionSystem Status Input and Output Functions Switch TroubleshootingUse the following table to help troubleshoot problems StandbyThis fault can be caused by Constant Controller ErrorPower. If the error persists, replace controller Incorrect setting of Motor Overload Setting switchesSet the meter to read DC current mA Connect the black lead from the meter to terminalSensor cable Megger readings Blinks Temperature This fault can be caused byTemperature reaches 104 ºF 40ºC To 50% or lowerGreater than 275V for 230V units and 560V for 460V units 10Hz for 5 minutesController Dimensions Appendix Input Wire Sizing Charts InputPage IM213 Revision Number November

IM213 specifications

ITT IM213 is a prominent electronic device designed for data acquisition and monitoring in various industrial applications. Known for its robust construction and versatile functionality, the IM213 series has gained significant traction in sectors such as manufacturing, environmental monitoring, and energy management.

One of the key features of the ITT IM213 is its advanced data logging capability. The device can record a wide range of signals, including temperature, pressure, and humidity, making it an essential tool for real-time monitoring. The intuitive user interface allows users to configure the device easily, adjusting parameters to suit specific monitoring needs.

The IM213 utilizes cutting-edge technologies to ensure accuracy and reliability. Its high-resolution analog-to-digital converters (ADCs) offer precise measurements with minimal noise interference, enhancing the overall performance of the device. Additionally, the device supports multiple communication protocols, including Modbus, RS-232, and RS-485, enabling seamless integration into existing systems.

Another noteworthy characteristic of the ITT IM213 is its robust build quality. Designed for use in harsh environments, it features an IP67-rated enclosure that protects it from dust, moisture, and other potential contaminants. This makes it particularly suitable for outdoor applications or locations with challenging conditions.

Furthermore, the IM213 is equipped with a range of connectivity options. Users can connect the device to cloud platforms for remote monitoring and data analytics, leveraging IoT technologies to enhance operational efficiency. This capability allows organizations to make data-driven decisions, improving their overall productivity.

The device also supports customizable alert systems, notifying users of any deviations from preset thresholds in real-time. This feature is crucial for preventing costly downtime and ensuring that processes remain within optimal operational parameters.

In terms of power consumption, the ITT IM213 is designed to be energy-efficient, ensuring long operational life and reduced running costs. Its low-power modes further contribute to sustainability, making it a responsible choice for environmentally conscious organizations.

In summary, the ITT IM213 is a versatile and durable data acquisition device that serves a wide range of industrial applications. Its advanced logging capabilities, high accuracy, robust construction, and connectivity options position it as a leading choice for professionals looking to improve their monitoring and data collection efforts. With these features, the IM213 is poised to play a vital role in enhancing productivity and operational efficiency in various sectors.