ITT IM213 manual Power Supply and Wiring, Delta/Wye with grounded Wye neutral

Page 9

Mounting the Controller

Section 5 (continued)

Note

Do not block the heat sink (fins) and fans and do not set anything on the units.

Warning

WARNING

Hazardous voltage

The controller access cover should always be securely fastened to the control box due to the dangerous voltage/shock hazard inside the unit. A lock can be used to prevent unwanted entry.

Power Supply and Wiring

Section 6

Power Supply

Note

Installation and maintenance MUST be performed by properly trained and qualified personnel. Always follow the National Electrical Code (NEC) or Canadian Electric Code (CEC), as well as all state, local and provincial codes when wiring the system.

The type of transformer and the connection configuration feeding a drive plays an important role in its performance and safety. The following is a brief description of some of the more common configurations and a discussion of their virtues and shortcomings. Always ask what type of power system the site has before sizing the drive.

Delta/Wye with grounded Wye neutral

This configuration is one of if not the most common. It provides rebalancing of unbalanced voltage with a 30 degree phase shift. Depending on the output connections from the drive to motor, the grounded neutral may be a path for common mode current caused by the drive output.

9

Image 9
Contents IM213 Commercial Water ITTIndex Death Safety InstructionsController Product Code Information System ComponentsHP = Volt =Fusible Disconnect System DesignSection Diagram #2 shows a set-up for municipal water connectionPiping Installing the Pressure SensorGeneral Pressure Tank, Pressure Relief Valve and Discharge PipingMounting the Controller Power Supply and Wiring Power SupplyDelta/Wye with grounded Wye neutral Ungrounded secondary Delta/Delta with grounded legResistance grounding and ground fault protection Open Delta consult factoryFor Frame Size 1 Controllers Single Phase Connection 208/230460 20ºC 30ºC 40ºC 50ºC Conduit, Wire and Fuse SizingInput Power and Line Transformer Requirements Output Power ConnectionsStarting the System Input Power Connections Chart below shows the motor overload setting for each model Setting the Motor Overload SwitchesSetting the No Water Restart Time Switches Setting the Acceleration/Deceleration SwitchesSetting the Minimum Frequency Switch Setting the Carrier Frequency SwitchSetting the Pressure Motor Rotation DirectionSystem Status Input and Output Functions Use the following table to help troubleshoot problems TroubleshootingSwitch StandbyPower. If the error persists, replace controller Constant Controller ErrorThis fault can be caused by Incorrect setting of Motor Overload Setting switchesSet the meter to read DC current mA Connect the black lead from the meter to terminalSensor cable Temperature reaches 104 ºF 40ºC Blinks Temperature This fault can be caused byMegger readings To 50% or lower10Hz for 5 minutes Greater than 275V for 230V units and 560V for 460V unitsController Dimensions Input Appendix Input Wire Sizing ChartsPage IM213 Revision Number November

IM213 specifications

ITT IM213 is a prominent electronic device designed for data acquisition and monitoring in various industrial applications. Known for its robust construction and versatile functionality, the IM213 series has gained significant traction in sectors such as manufacturing, environmental monitoring, and energy management.

One of the key features of the ITT IM213 is its advanced data logging capability. The device can record a wide range of signals, including temperature, pressure, and humidity, making it an essential tool for real-time monitoring. The intuitive user interface allows users to configure the device easily, adjusting parameters to suit specific monitoring needs.

The IM213 utilizes cutting-edge technologies to ensure accuracy and reliability. Its high-resolution analog-to-digital converters (ADCs) offer precise measurements with minimal noise interference, enhancing the overall performance of the device. Additionally, the device supports multiple communication protocols, including Modbus, RS-232, and RS-485, enabling seamless integration into existing systems.

Another noteworthy characteristic of the ITT IM213 is its robust build quality. Designed for use in harsh environments, it features an IP67-rated enclosure that protects it from dust, moisture, and other potential contaminants. This makes it particularly suitable for outdoor applications or locations with challenging conditions.

Furthermore, the IM213 is equipped with a range of connectivity options. Users can connect the device to cloud platforms for remote monitoring and data analytics, leveraging IoT technologies to enhance operational efficiency. This capability allows organizations to make data-driven decisions, improving their overall productivity.

The device also supports customizable alert systems, notifying users of any deviations from preset thresholds in real-time. This feature is crucial for preventing costly downtime and ensuring that processes remain within optimal operational parameters.

In terms of power consumption, the ITT IM213 is designed to be energy-efficient, ensuring long operational life and reduced running costs. Its low-power modes further contribute to sustainability, making it a responsible choice for environmentally conscious organizations.

In summary, the ITT IM213 is a versatile and durable data acquisition device that serves a wide range of industrial applications. Its advanced logging capabilities, high accuracy, robust construction, and connectivity options position it as a leading choice for professionals looking to improve their monitoring and data collection efforts. With these features, the IM213 is poised to play a vital role in enhancing productivity and operational efficiency in various sectors.