TROUBLESHOOTING (cont.)
PROBLEM
PROBABLE CAUSE | REMEDY |
Product will not dispense (cont.)
9.Water strainer
10.Lime
CAUTION - Tank and tank compo- nents should be delimed regularly depending on local water conditions. Excessive mineral
(A)Direction of flow arrow must be pointing towards dispenser.
(B)Remove the strainer and check for obstructions. Clear or replace.
Inspect the tank assembly for exces- sive lime deposits. Delime as re- quired.
Water is not hot
1. Limit thermostat | Refer to Service - Limit Thermostat |
CAUTION - Do not eliminate or by- | for testing procedures. See page 26 |
pass limit thermostat. Use only BOM |
|
replacement part #29329.1000 |
|
2. Control thermostat | Refer to Service - Control Thermo- |
| stat for testing procedures. See page |
| 16 |
Spitting or excessive steaming
3.Tank Heater
4.Tank heater switch
1. Lime
CAUTION - Tank and tank compo- nents should be delimed regularly depending on local water conditions. Excessive mineral
Refer to Service - Tank Heater for testing procedures. See page 32
Refer to Service - Tank Heater Switch for testing procedures. See page 33
Inspect tank assembly for excessive lime deposits. Delime as required.
2. Control thermostat | Refer to Service - Control Thermo- |
| stat for testing procedures. See |
| page 16 |
8 | 28364 051100 |
|